This study was designed to study on major components of various Bee Venom(Bee Venom by electrical stimulation in Korea; K-BV I, Bee Venom by Microwave stimulation in Korea; K-BV II, 0.5mg/ml, Fu Yu Pharmaceutical Factory, China; C-BV, 1mg/ml, Monmouth Pain Institute, Inc., U.S.A.; A-BV) using HPLC(H...
This study was designed to study on major components of various Bee Venom(Bee Venom by electrical stimulation in Korea; K-BV I, Bee Venom by Microwave stimulation in Korea; K-BV II, 0.5mg/ml, Fu Yu Pharmaceutical Factory, China; C-BV, 1mg/ml, Monmouth Pain Institute, Inc., U.S.A.; A-BV) using HPLC(High performance liquid chromatography). The results were summarized as follows : 1. HPLC method is useful for analysis of Bee Venom when solution rate is above 1:4000. 2. Analysis of Apamin using HPLC, the Retention time was 8.7min, and standard measurement curve was a function of y=4E+06x+21245. 3. Analysis of Melittin using HPLC, the Retention time was 29.0 min, and standard measurement curve was a function of y=4E+06x+23015. 4. Concentration of Melittin was about 297times than Apamin in K-BV I, and about 329times in K-BV II at same 1:500 solution rate, abnormally about 12 times in C-BV at 1:4000 solution rate. 5. Chinese Bee Venom using HPLC, the point from 5 to 7min(Retention time) showed a big extraordinary peak. These data from the study can be applied to establish the standard measurement of Bee Venom and prevent pure bee venom from mixing of another components. I think it is desirable to study more about safety of Bee Venom as time goes by.
This study was designed to study on major components of various Bee Venom(Bee Venom by electrical stimulation in Korea; K-BV I, Bee Venom by Microwave stimulation in Korea; K-BV II, 0.5mg/ml, Fu Yu Pharmaceutical Factory, China; C-BV, 1mg/ml, Monmouth Pain Institute, Inc., U.S.A.; A-BV) using HPLC(High performance liquid chromatography). The results were summarized as follows : 1. HPLC method is useful for analysis of Bee Venom when solution rate is above 1:4000. 2. Analysis of Apamin using HPLC, the Retention time was 8.7min, and standard measurement curve was a function of y=4E+06x+21245. 3. Analysis of Melittin using HPLC, the Retention time was 29.0 min, and standard measurement curve was a function of y=4E+06x+23015. 4. Concentration of Melittin was about 297times than Apamin in K-BV I, and about 329times in K-BV II at same 1:500 solution rate, abnormally about 12 times in C-BV at 1:4000 solution rate. 5. Chinese Bee Venom using HPLC, the point from 5 to 7min(Retention time) showed a big extraordinary peak. These data from the study can be applied to establish the standard measurement of Bee Venom and prevent pure bee venom from mixing of another components. I think it is desirable to study more about safety of Bee Venom as time goes by.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.