최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기대한치과보철학회지 = The journal of Korean academy of prosthodontics, v.40 no.2, 2002년, pp.193 - 200
For the purpose of decreasing the chair time in implant cases, the time needed to loosening and fastening the screw must be shortened. Nowadays, the two typical designs of screw head are slot and hexa form. This study aimed at the shortening of loosening and fastening time by modifying the slot and ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Albrektsson T, Dahl E, Enbom L, Engevall S, Engquist B, Eriksson AR, Feldmann G, Freiberg N, Glantz PO, Kjellman O, Osseointegratedoral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants. J Periodontol. 1988 May:59(5) :287-96
Zarb GA Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent. 1990 Aug:64(2): 185-94
Jemt T, Linden B, Lekholm U. Failures and complicationsin 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants. 1992 Spring:7(1):4G-4
Goodacre CJ, Kan JY, Rungcharassaeng K. Clinical complications of osseointegrated implants. J Prosthet Dent. 1999 May: 81(5) :537-52. Review
Ekfeldt A. Carlsson GE. Borjesson G. Clinical evaluation of single-tooth restorations supported by osseointegrated implants: a retrospective study. Int J Oral Maxillofac Implants. 1994 Mar-Apr: 9(2) :179-83
Haas R. Mensdorff-Pouilly N, Mailath G, Watzek G. R Branemark single tooth implants: a preliminary report of 76 implants. J Prosthet Dent. 1995 Mar:73(3) :274-9
Becker W, Becker BE. Replacement of maxillary and mandibular molars with single endosseous implant restorations: a retrospective study, J Prosthet Dent. 1995 Jul: 74(1): 51-5
Gunne J. Astrand P. Ahlen K. Borg K. Olsson M. Implants in partially edentulous patieents. Clin Oral Implant Res 1992:3:49-56
Jemt T, Pettersson P. A 3-year follow-up study on single implant treatment. J Dent. 1993 Aug:21(4) :203-8
emt T, Book K. Linden B, Urde G. Failures and complications in 92 consecutively inserted overdentures supported by Branemark implants in severely resorbed edentulous maxillae: a study from prosthetic treatment to first annual check-up. Int J Oral Maxillofac Implants. 1992 Summer.7(2): 162-7
Albrektsson T. A multicenter report on osseointegrated oral implants. J Prosthet Dent. 1988 Jul: 60 (1) :75-84. Review
Tolman DE, Laney WR. Tissue-integrated dental prostheses: the first 78 months of experience at the Mayo Clinic. Mayo Clin Proc. 1993 Apr:68(4) :323-31
Allen PF, McMillan AS. Smith DG. R. Complications and maintenance requirements of implant-supported prostheses provided in a UKdental hospital. Br Dent J. 1997 Apr 26:182(8):298-302
Gunne J, Jemt T. Linden B. Implant treatment in partially edentulous patients: a report on prostheses after 3 years. Int J Prosthodont. 1994 Mar-Apr:7(2): 143-8
Avivi-Arber L. Zarb GA. Clinical effectiveness of implant-supported single-tooth replacement: the Toronto Study. Int J Oral Maxillofac Implants. 1996 May-Jun: 11(3) :311-21
Zarb GA Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent. 1990 Aug:64(2): 185-94
Naert I, Quirynen M, van Steenberghe D, Darius P. A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects.J Prosthet Dent. 1992 Dec:68(6) :949-56
Wismeyer D, van Waas MA Vermeeren JI. Overdentures supported by ITI implants: a 6.5-year evaluation of patient satisfaction and prosthetic aftercare. Int J Oral Maxillofac Implants. 1995 Nov-Dec: 10(6):744-
Laboda G. RLife-threatening hemorrhage after placement of an endosseous implant: report of case. J Am Dent Assoc. 1990 Nov: 121 (5) :599-600
ten Bruggenkate CM, Krekeler G, Kraaijenhagen HA, Foitzik C, Oosterbeek HS. Hemorrhage of the floor of the mouth resulting from lingual perforation during implant placement: a clinical report. Int J Oral Maxillofac Implants. 1993:8(3) :329-34
Adell R. Lekholm U, RockIer B, Branemark PI, Lindhe J, Eriksson B, Sbordone L. Marginal tissue reactions at osseointegrated titanium fixtures (I). A 3-year longitudinal prospective study. Int J Oral Maxillofac Surg. 1986 Feb:15(1):39-52
Hemmings KW, Schmitt A, Zarb GA. Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report. Int J Oral Maxillofac Implants. 1994 Mar-Apr: 9(2) :191-6
Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH Jr, Polizzi G, Zarb GA Herrmann I. Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants. 1991 Spring: 6 (1) :29-36
Cordioli G, Castagna S, Consolati E. Singletooth implant rehabilitation: a retrospective study of 67 implants. Int J Prosthodont. 1994 Nov-Dec: 7(6) :525-31
Andersson B, Odman P, Lindvall AM, Branemark PI. Five-year prospective study of prosthodontic and surgical single-tooth implant treatment in general practices and at a specialist clinic. Int J Prosthodont. 1998 JulAug: 11(4) :351-5
Patterson EA Johns RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants. 1992 Spring: 7(1) :26-33
Gross M, Abramovich I. Weiss EI. Microleakage at the abutment-implant interface of osseointegrated implants: a comparative study. Int J Oral Maxillofac Implants. 1999 JanFeb:14(1) :94-100
Kramer,R. Procedure for obturating the access canal and preventing the loosening of the abutment screw in an implant-retained fixed prosthesis. J Prosthet Dent 1999:81:234-6
Adrian ED, Krantz WA, Ivanhoe JR, Edge MJ. An improved index for the waxed stage of an implant-retained framework. J Prosthet Dent. 1991 Nov:66(5) :665-9
Artzi Z, Dreiangel A. A screw lock for singletooth implant superstructures. J Am Dent Assoc. 1999 May: 130(5) :677-82
신승요, 신근하, 김영조. 나사기술총람, 문운당. 1995
이호용, 임종연, 이종찬, 황병복. 제조공학, 반도출판사. 1998
김동우, 김태형, 허정원, 황규완. 기계공학개론, 원창출판사, 1999
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.