최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기대한치과보철학회지 = The journal of Korean academy of prosthodontics, v.41 no.4, 2003년, pp.393 - 404
오세웅 (서울대학교 치과대학 치과보철학교실) , 양재호 (서울대학교 치과대학 치과보철학교실) , 이선형 (서울대학교 치과대학 치과보철학교실) , 한중석 (서울대학교 치과대학 치과보철학교실)
Statement of problem. Higher incidence of prosthetic complications such as screw loosening, screw fracture has been reported for posterior single tooth implant. So, there is ongoing research regarding stability of implant-abutment interface. One of those research is increasing the implant diameter a...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Branemark P-I, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw:Experience from a ten year period, Scand J Plastic Reconst Surg 1977;11(suppl)
Adell R. Lekholm U. RockIer B. Branemark P-I, A 15-yr study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416
Sones AD. Complications with osseointegrated implants, J Prosthet Dent 1989; 62:582-585
Kallus T. Bessing C. Loose gold screws frequently occur in full arch fixed prostheses supported by osseointegrated implants for 5years, Int J Oral Maxillofac Implants 1994;9:169-178
Beaty K. The role of screws in implant systems, Int J Oral Maxillofac Implants 1994;9(suppl):52-54
Binon PP. Evaluation of machining accuracy and consistency of selected implants, standard abutments nad laboratory analogs. Int J Prosthodont 1995;8:162-178
Jemt T. Pettersson P. A 3-year follow-up study on single implant treatment, J Dent 1993;21:203-208
Walton JN, MacEntee MI. A prospective study on the maintenance of implant prostheses in private practice, Int J Prosthodont 1997;10:453-458
Binon PP. Implants and components : entering the new millennium. Int J Oral Maxillofac Implants 2000;15:76-94
Haas R. Mensdorff-Pouilly N. Mailath G. Watzek G. Branemark single tooth implants : A preliminary report of 76 implants. J Prosthet Dent 1995;73:274-279
Jorneus L. Screws and cylinders in the Nobelpharma implant system, Nobelpharma News 1987;1:7
Boggan RS, Strong JT, Misch CE, Bidez MW. Influence of hex geometry and table width on static and fatigue strength of dental implants, J Prosthet Dent 1999;82:436-40
Michael R Norton. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Impl Res 1997;8:290-298
Levine R, Clem D, Beagle J, Ganeles J, Johnson P, Solnit G, Keller G. Multicenter Retrospective Analysis of the Solid-Screw ITI Implant for Posterior Single-Tooth Replacements, Int J Oral Maxillofac Implants 2002;17:550-556
Lee JM, Kim YS, Kim CW, Kim YH, 3-D FEA of three different single tooth abutment : cement-retained vs screw-retained, J Korean Acad Prosthodont 1999: 37(2):269-280
Jang KS, Kim YS, Kim CW. Three deimensional finite element analysis on the minimum contact fraction of bone-implant interface, J Korean Acad Prosthodont 1997;35(4):627-640
Weinberg LA, The biomechanics of force distribution in implant-supported prostheses, Int J Oral Maxillofac Implants 1993;8:19-31
Weinberg LA, The biomechanics of force distribution in implant-supported prostheses, Int J Oral Maxillofac Implants 1993;8:19-31
Haas R, Polak C, Furhauser R, MailathPokorny G, Dortbudak O, Watzek G. A long-term follow-up of 76 Branemark single implants, Clin Oral Impl Res 2002; 13:38-43
Merz BR, Hunenbart S, Belser UC, Mechanics of the implant-abutment connection : An 8-degree taper comapred to a butt joint connection. Int J Oral Maxillofac Implants 2000;15:519-526
Craig RG, Restorative Dental Materials. Ed 6, St Louis : Mosby, 1980:60-61
Richter EJ, In vivo vertical forces on implants. Int J Oral Maxillofac Implants 1995;10:99-108
Davarpanah M, Martinez H, Kebir M, Etienne D, Tecucianu JF, Wide-diameter implants: New concepts. Int J Perio Rest Dent 2001;21:149-159
Jarvis W. Biomechanical advantages of wide-diameter implants, Compend Contin Educ Dent 1997;18(7): 687-694
Hoyer SA, Stanford CM, Buranadham S, Fridrich T, Wagner J, Gratton D. Dynamic fatigue properties of the dental implantabutment interface : Joint opening in wide-diameter versus standard-diameter hex-type implants. J Prosthet Dent 2001; 85:599-607
Boggan RS, Strong JT, Misch CE, Bidez MW, Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implant. J Prosthet Dent 1999;82:436-40
Ivanoff CJ, Gyrondahl K, Bergstrom C, Lekholm U, Branemark PI, Influence of variations in implant diameter : A3-to 5-year retrospective clinical report. Int J Oral Maxillofac Implants 1999;14:173-180
English C, Bahat O, Langer B, Sheets CG, What are the clinical limitations of wide-diameter root form endosseous implants? Int J Oral Maxillofac Implants 2000;15:293-294
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.