Abstract

Statement of problem: Resonance frequency analysis (RFA) has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized baseline data using RFA. Purpose: This study was performed to evaluate RFA value changes in two stage surgery group and one stage surgery group in patients. Material and method: Forty-seven mandibles in consecutively implant installed patients were selected for this study and 141 fixtures were installed. Ninety-three fixtures were double threaded, machined surface design ($Br{\aa}anemark^{(R)}$ MK III, Nobel Biocare AB, Goteborg, Sweden) and 48 fixtures were root form, threaded, HA-coated surface one ($Replace^{TM}$, Steri-Oss/Nobel Biocare AB, USA). Among those, each 10 fixture was installed in one stage group patients. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, at healing abutment connection and in the loading period for two stage surgery group patients and during at each 4, 6, 8, 10, 12week and in the loading phase for one stage surgery group patients and evaluated the changes according to the time and fixture type. Results: In two stage surgery group, mean and SO of ISQ values of machined surface implants were $76.85{\pm}3.74,\;75.76{\pm}5.04,\;75.73{\pm}4.41$ and those of HA-coated surface implant were $75.05{\pm}6.23,\;77.58{\pm}5.23,\;78.32{\pm}4.29$ during fixtures installation, at healing abutment connection and in the loading period, respectively. In one-stage surgery group, the ISQ values of machined surface and HA-coated surface implants decreased until 4 or 6 week and maintained at plateau for 1-3 week and increased to the loading period. Conclusions: Machined and HA-coated surface implants showed minimal ISQ changes with time if they were installed at the sites showing at least intact cortical plate and good bone qualities. And HA-coated implants had a tendency to show somewhat increased ISQ values with time.

저자의 다른 논문

참고문헌 (32)

  1. Albrektsson T, Branemark PI, Hansson H, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a longlasting direct boneto- implant anchorage in man. Acta Orthop Scan 1981;52:155-170 
  2. Adell R, Lekholm U, RockIer B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416 
  3. Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated implants. A review of the literature. Int J Prosthodont 1998;11:408-420 
  4. Albrektsson T, Sennerby L. State of the art in oral implants. J Clin Periodontol 1991;18:474-481 
  5. Meredith N. Assessment of implant stability as a prognotic determinant. Int J Prosthodont 1998;11:491-501 
  6. Sennerby L, Meredith N. Resonance Frequency Analysis: Measuring implant stability and osseointegration. Compendium 1998;19:493-502 
  7. Park C. A study of the measurement of the implant stability using resonance requency analysis. PhD thesis, 2000, Dankook University, Korea 
  8. $Osstell^{TM}$ resonance frequency analyser. Clinical Manual. Integration Diagnostics Ltd. S$\"{a}$vedalen, Sweden. 2002 
  9. Lekholm U, Zarb GA. Patient selection and preparation, in Branemark PI, Zarb GA, Albrektsson T.(eds): Tissue-Integrated Prostheses : Osseointegration in Clinical Dentistry. Chicago:Quintessence, 1985:199-209 
  10. Tal H. Spontaneous early exposure of submerged implants: I. Classification and clinical observations. J Periodontol 1999;70:213-219 
  11. Tal H, Dayan D. Spontaneous early exposure of submerged implants: II. Histopathology and histomorphometry of non-perforated mucosa covering submerged implants. J Periodontol 2000;71:1224-1230 
  12. Tal H, Dayan D. Spontaneous early exposure of submerged implants: III. Histopathology of perforated mucosa covering submerged implants. J Periodontol 2000;71:1231-1235 
  13. Meredith N. On the clinical measurement of implant stability and osseointegration. PhD thesis, 1997, University of Gothenburg, Sweden 
  14. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Impl Res 1996;7:261-267 
  15. Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in-vivo: A cross sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Impl Res 1997;8:226-233 
  16. Meredith N, Sagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurement to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Impl Res 1997;8:234-243 
  17. Sennerby L, Friberg B, Linden B, Jemt T, Meredith N. A comparison of implant stability in mandibular and maxillary bone using RFA. European Commission Demonstration Project. Resonance Frequency Analysis Symposium. 2000, Gothenburg, Sweden 
  18. Al-Nawas B, Groetz KA, Brahm R, Wagner W. Resonance-frequency-analysis in the healing and loading period of dental implants. IADR abstracts 2002;1027 
  19. Park CJ. Stability measurement on the implants of mandibular molar area using $Osstell^{TM}$. J Korean Academy of Stomatognathic Function and Occlusion 2001;17:205-211 
  20. Friberg B. On bone quality and implant stability measurements. PhD thesis. 1994, University of Gothenburg, Sweden 
  21. Friberg B, Sennerby L, Roos J, Johansson P, Strid CG, Lekholm U. Evaluation of bone density using cutting resistance measurements and microradiography. : An in vitro study in pig ribs. Clin Oral Impl Res 1995;6:164-171 
  22. Friberg B, Sennerby L, Roos J, Lekholm U. Identification of bone quality in conjunction with insertion of titanium implants. Clin Oral Impl Res 1995;6:213-219 
  23. Johansson P, Strid KG. Assessment of bone quality from cutting resistance during implant surgery. Int J Oral Maxillofac Impl 1994;9:279-288 
  24. Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofacial Surg 1999a;28:297-303 
  25. Buser D, Mericske-Stern R, Bernard JP. Longterm evaluation of non-submerged ITI implants. Part 1:8-year life table analysis of a prospective multicenter study with 2359 implants. Clin Oral Impl Res 1997;8:161-172 
  26. Buser D, Weber HP, Bragger U, Balsiger C. Tissue integration of one-stagem implants :3-year results of a longitudinal study with hollow-cylinder and hollow-screw implants. Int J Oral Maxillofac Impl 1991;6:405-412 
  27. Becker W, Becker B, Isarelson H. One-step surgical placement of Branemark implants: A prospective multicenter clinical study. Int J Oral Maxillofac Impl 1997;12:454-462 
  28. Ericsson I, Rainbow K, Glantz PO, Lindhe J, Nilner K. Clinical and radiographical features of submerged and nonsubmerged titanium implants. Clin Oral Impl Res 1994;5:185-189 
  29. Ericsson I, Rainbow K, Nilner K, Petersson A. Some clinical and radiographical features of submerged and non-submerged titanium implants. A 5-year follow-up study. Clin Oral Impl Res 1997;8:422-426 
  30. Friberg B, Sennerby L, Linden B, Grondahl K, Lekholm U. Stability measurements of one-stage Br${\aa}$nemark implants during healing in mandibles. A clinical resonance frequency study. Int J Oral Maxillofac Surg 1999b;28:266-272 
  31. Park CJ. In vitro comparative study between ISQ and Peritcst $^\circledR$ values on the implant stability measurements according to the increased effective implant length. J Korean Academy of Prosthodontics 2001;39:625-635 
  32. Toljanic J, Banakis M, Willes L, Graham L. Soft tissue exposure of endosseous implants between stage I and stage II surgery as a potential indicator of early crestal bone loss. Int J Oral Maxillofac Impl 1999;14:436-441 

이 논문을 인용한 문헌 (3)

  1. 2004. "" 대한치과보철학회지 = The journal of Korean academy of prosthodontics, 42(6): 671~678 
  2. Kim Sun-Jong ; Shin Sang-Wan ; Jung Sung-Min ; Ryu Jae-Jun 2005. "A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS" 대한치과보철학회지 = The journal of Korean academy of prosthodontics, 43(1): 78~94 
  3. Choi, Jeong-Hun ; Lee, Ju-Min ; Kim, Yong-Deok ; Shin, Sang-Hun ; Chung, In-Kyo 2010. "ASSESSMENT OF BONE DENSITY ON MAXILLA AFTER IMPLANTATION WITH CONE BEAM COMPUTED TOMOGRAPHY" 대한악안면성형재건외과학회지 = The journal of Korean association of maxillogacial plastic and reconstructive surgeons, 32(3): 229~235 

원문보기

원문 PDF 다운로드

  • ScienceON :

원문 URL 링크

원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다. (원문복사서비스 안내 바로 가기)

상세조회 0건 원문조회 0건

DOI 인용 스타일