NTIS 바로가기설비공학논문집 = Korean journal of air-conditioning and refrigeration engineering, v.18 no.3, 2006년, pp.231 - 239
김봉훈 (대구대학교 자동차.산업.기계공학부) , 최준민 (한국항공우주연구원)
An experimental investigation of a Reversible Loop Heat Pipe (RLHP) was conducted to determine the operating limits and performance characteristics as functions of the thermophysical parameters, the heat input, and the cooling intensity. Variations in both temperature and heat transport capacity wer...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Laub, J. H. and McGinness, H. D., 1961, Recirculation of a two-phase fluid by thermal and capillary pumping, Technical Report No. 32-196, Jet Propulsion Laboratory, California Inst. Tech., December 3
McGinness, H. D., 1961, Capillary pumping for closed-cycle gas systems, Research Summary No. 36-10, Vol., 1, Jet Propulsion Laboratory, California Inst. Tech., September 1, pp.9-13
Stenger, F. J., 1966,. Experimental feasibility study of water-filled capillary-pumped heattransfer loop, NASA TM X -1310, Lewis Research Center, Cleveland, OH, August 3
Faghri, A., 1995, Heat pipe science and technology, Taylor Francis
Ku, J. and Yun, S., 1992, A prototype heat exchanger for the capillary pumped loop flight experiment, AIAA Paper 92-2910
Maidanik, Y, Vershinin, S., Kohlodov, V. and Dolgirev, J. 1985, Heat transfer apparatus, US Patent No. 4515209, May 7
Maidanik, Y, Fershtater, S. and Goncharov, K., 1991, Capillary-pumped loop for the systems of thermo regulation of spacecraft, ESA SP-324, December 15
Dickey, J. T. and Peterson, G. P., 1994, An experimental and analytical investigation of the operational characteristics of a capillary pumped loop, Journal of Thermophysics and Heat Transfer, Vol. 8, No.3, pp.602-607
ASHRAE, 1986, Standard methods for temperature measurement, ANSI/ASHRAE 41.4
Dunn, P. and Reay, D., 1982, Heat Pipes, 3rd ed., Pergamon Press, New York
Daubert, T. E. and Danner, R. P., 1981, Physical and Thermodynamic Properties of Pure Chemicals, Data Compilation, Hemisphere Publinshing Corporation, New York
ASHRAE, 1985, Fundamentals handbook, CH. 18, pp. 1-10
Kaya, T. and Hoang, T. T., 1999, Mathematical modeling of loop heat pipes and experimental validation, Journal of Thermophysics and Heat Transfer, Vol. 13, No.3, pp.314-320