Abstract

This study was conducted to develop a 100 kPa soil tensiometer mainly consisted of a porous ceramic cup, water-holding tube, and a digital vacuum gauge, through theoretical design analysis and experimental performance evaluation. Major findings were as follows. 1. Theoretical analysis showed that air entry value of a porous media decreased as the maximum effective size of the pore increased, and the maximum diameter of the pores was $2.9\;{\mu}m$ for measuring up a 100 kPa of soil-water tension. 2. Property analysis of tensiometer porous cups supplied in Korean domestic market indicated that main components were $SiO_2$ and $Al_2O_3$ with a porosity range of $33.8{\sim}49.3%$. 3. The porous cup selected through sample fabrication and air-permeability tests showed weight ratios of 87% and 11% for $Al_2O_3$ and $SiO_2$. The analysis of SEM (scanning electron microscope) images showed that the sample was sintered at temperatures of about $1150^{\circ}C$, which consisted of pores with sizes of up to 25% of those for commercial porous cups. 4. The prototype soil tensiometer was fabricated using the developed porous cup and a digital vacuum gauge that could measure water tension with a pressure of 85 kPa in air tests. 5. In-soil tests of the prototype conducted during a period of 25-day drying showed that soil-water tension values measured with the prototype and commercial units were not significantly different, and soil-water characteristic curves could be established for different soils, confirming accuracy and stability of the prototype.

참고문헌 (8)

  1. Barber, S. A. 1984. Nutrient uptake by plant roots growing in soil. In Soil Nutrient Bio-availability: A Mechanistic Approach. New York, N.Y.: John Wiley & Sons, Inc 
  2. Hillel, D. 1980. Fundamentals of Soil Physics. Academic Press, INC 
  3. Lu, N. and W. J. Likos. 2004. Unsaturated Soil Mechanics. New York, N.Y.: John Wiley & Sons, Inc 
  4. Soil Science Society of America. 2002. Methods of Soil Analysis, Part 4 - Physical Methods, SSSA Book Series, No. 5. pp. 417-669. Soil Science Society of America, Inc., Madison, Wise., USA 
  5. Stannard, D. I. 1992. Tensiometers-theory, construction, and use. Geotechnical Testing Journal, GTJODJ. 15(1):48-58 
  6. 김철기, 이기춘. 1996. 신고 농업수리학. 향문사 
  7. 엄기철. 2003. 시설재배지의 관비기술개발 방향. 한국시설원예연구회 제 17회 심포지엄 자료집: 고품질 원예산물 생산 위한 관비재배 현황과 발전방향.pp. 2-15. 한국시설원예연구회, 부산 
  8. 이용구,김기덕,남윤일,조얼환,김태영,남은영,문보흠 .2004. 토양수분계측 및 자동관수용 텐시오미터. 대한민국 실용신안 등록번호:20-0354141 