NTIS 바로가기Journal of biomedical engineering research : the official journal of the Korean Society of Medical & Biological Engineering, v.29 no.5, 2008년, pp.371 - 375
오홍식 (한양대학교 의용생체공학과) , 이종실 (한양대학교 의용생체공학과) , 김영수 (한양대학교 의과대학 신경외과) , 신동범 (한양대학교 의용생체공학과) , 김인영 (한양대학교 의용생체공학과) , 지영준 (한양대학교 의용생체공학과)
In blood pressure measurement, the oscillometric method detects and analyzes the pulse pressure oscillation while deflating the cuff around the arm. For its principle, one has to inflate cuff pressure above the subject's systolic pressure and deflate below the diastolic pressure. Most of the commerc...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Geddes, L.A., V. Chaffee, S.W. Whistler, J.D. Bourland, and W.A. Tacker. Indirect mean blood pressure on the anesthetized pony. Am. J. Vet. Res. 28:2055-2057, 1977
Ramsey, M. Noninvasive automatic determination of mean arterial pressure. Med. Biol. Eng. Comput. 17:17-18, 1979
Geddes, L.A. and A.G. Moore. The efficient detection of Korotkoff sounds. Med. Biol. Eng. 6161:603-609, 1968
D.K. Roh, Y.S. Lee, J.H. Jie, S.B. Park, K.H. Lee, H.K. Kim, "Design of the Blood Pressure Measurement System Using The Inflation Oscillometric Method", J. Biomed. Eng. Res. Vol.24, 4:281-286, 2003
National High Blood Pressure Education Program, The Seventh Report of the Joint National Committe on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure
N. Morioka, M. Ozaki, K. Ozaki, Di Sessler, T. Matsukawa, H. Suzuki, Measurement of Non-Invasive Oscillometric Blood PRessure During Cuff Inflation, Rather than Deflation, Anesthesiology, Vol.87, pp.A431, 1997
L.A.Geddes, M.Voelz. C.Combs. D.Reiner, C.F.Babbs, "Characterization of the oscillometric method for measuring indirect blood pressure", Ann Biomed Eng.1892, 10:271-280
Alan M. Gross, "Confidence Intervals for Bisquare Regression Estimates", J. American statistical Association, Vol.72, No. 358(Jun.,1977), pp. 341-354
Chemla D, Hebert JL, Zamani K, Coirault C, Lecarpentier Y. A new formula for estimating mean aortic pressure. Lancet 1999; 353: 1069-70
Eoin O'Brien, Neil Atkins. "validation and Reliability of Blood Pressure Monitors". Clinical Hypertension and Vascular Disease, Blood Pressure Monitoring in Cardiovascular Medicine and Therapeutics 2nd Edition
Jiri Jilek, Teiichiro Fukushima, "Oscillometric Blood Pressure Measurement : The Methodology, Some Observations, and Suggestions", Biomedical Instrumentation & Technology 2005; 39:237-241
Razminia M, Trivedi A, Molnar J, Elbzour M, Guerrero M, Salem Y, Ahmed A, Khosla S, Lubell DL. "Validation of a new formula for mean arterial pressure calculation: The new formula is superior to the standard formula", Catheter Cardiovasc Interv. 2004 Dec;63(4):419-25