NTIS 바로가기한국정보통신학회논문지 = Journal of the Korea Institute of Information and Communication Engineering, v.18 no.9, 2014년, pp.2197 - 2202
안호명 (Department of Digital Electronics, Osan University) , 서영호 (College of Liberal Arts, Kwangwoon University) , 양원재 (Division of Maritime Transportation System, Mokpo National Maritime University) , 김병철 (Department of Electronic Engineering, Gyeongnam National University of Science and Technology(GnTECH))
In this paper, we report on an investigation of highly sensitive sensing performance of a hydrogen sensor composed of palladium (Pd) nanowires. The Pd nanowires have been grown by electrodeposition into nanochannels and liberated from the anodic aluminum oxide (AAO) template by dissolving in an aque...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
핵심어 | 질문 | 논문에서 추출한 답변 |
---|---|---|
수소 에너지가 친환경 에너지인 이유는? | 수소 연료의 이용 특히, 수소 연료 자동차의 상용화가 수 년 내로 이루어질 것으로 예상되고 있으며, 분산발전, 동력 등의 분야에 우선적으로 소비 확대가 이루어질 전망이다[1]. 수소는 물로부터 얻을 수 있으며, 연소시 공해물질이 발생되지 않는 친환경 에너지이다. 하지만, 일정량의 수소가 산소와 결합할 때 자연발화하거나, 폭발하는 성질이 있기 때문에, 수소 에너지의 개발과 함께 이의 안전한 사용에 대한 연구도 같이 진행 되어야 한다[2]. | |
현재 개발된 수소의 누출을 조기에 알려 줄 수 있는 수소센서의 종류와 한계는? | 이를 위해서 수소의 누출을 조기에 알려 줄 수 있는 수소센서의 개발이 필요하다. 현재 연구된 수소센서는 촉매연소 또는 열선을 사용한 센서, 산화막, 알루미늄 질화 금속산화물 반도체 및 벌크 팔라듐(Pd), 백금(Pt)에 실리콘카바이드(SiC), 갈륨나이트라이드(GaN) 등을 이용하여 2극 구조의 쇼트키 장벽 다이오드를 사용한 센서 등 다양한 수소센서가 개발되어 있기는 하지만 크고 구조가 복잡하며 고가이거나, 300℃이상의 고온에서 동작하여 소비전력이 크고 수소에 대한 선택성이 떨어지는 등의 한계성을 지니고 있다[3-8]. 이에 그 성능을 최적화 할 수 있는 재료 및 구조에 대한 연구가 진행 중이며 대표적인 것으로는 나노기술을 소자에 응용하는 것과 나노재료를 센서재료로 사용하는 것이 있다. | |
수소 에너지 개발 시 안전에 유의해야 하는 이유는? | 수소는 물로부터 얻을 수 있으며, 연소시 공해물질이 발생되지 않는 친환경 에너지이다. 하지만, 일정량의 수소가 산소와 결합할 때 자연발화하거나, 폭발하는 성질이 있기 때문에, 수소 에너지의 개발과 함께 이의 안전한 사용에 대한 연구도 같이 진행 되어야 한다[2]. |
Sang Do Han, Su Kwon Lee, Hyeoun Sik Jung, "Trend of Hydrogen sensor technology," Hydrogen Information, vol. 1, p. 1, 2004.
T. Huberta, L. Boon-Brettb, G. Blackb, U. Banacha, "Hydrogen sensors-a review," Sens. Actuators B, vol. 157, p. 329, 2011.
Ivan Rygera, Gabriel Vankoa, Tibor Lalinskya, Pavol Kunzoa, Martin Valloa, Ivo Vavraa, Tomas Plecenikb, "Pt/NiO ring gate based Schottky diode hydrogen sensors with enhanced sensitivity and thermal stability," Sens. Actuators B, vol. 202, p. 1, 2014.
Da Chena, Jing Jing Wangb, De Hua Lia, Yan Xua, "Hydrogen sensor based on Pd-functionalized film bulk acoustic resonator," Sens. Actuators B, vol. 159, p. 234, 2011.
Cuili Xianga, Zhe She, Yongjin Zoua, Jun Chenga, Hailiang Chu, Shujun Qiu, Huanzhi Zhang, Lixian Sun, Fen Xua, "A room-temperature hydrogen sensor based on Pd nanoparticles doped TiO2 nanotubes," Ceramics International, vol. 128, p. 354, 2014.
E. A. Crespo, M. Ruda, S. R. de Debiaggi, E. M. Bringa, F. U. Braschi, G. Bertolino, "Hydrogen absorption in Pd nanoparticles of different shapes," Int. J. Hydrogen Energy, vol. 37, p. 14831, 2012.
J. Y. Kim, B. P. Gila, C. R. Abernathy, G. Y. Chung, R. Ren, S. J. Pearton, "Comparison of Pt/GaN and Pt/4H-SiC gas sensors," Solid-State Electronics, vol. 47, p. 1487, 2003.
J. Y. Kim, F. Ren, B. P. Gila, C. R. Abernathy, S. J. Pearton, "Reversible barrier height changes in hydrogen-sensitive Pd/GaN and Pt/GaN diodes," Appl. Phys. Lett., vol. 82, p. 739, 2003.
F. Favier, E. C. Walter, M. P. Zach, T. Benter, R. M. Penner, "Hydrogen Sensors and Switches from Electrodeposited Palladium Mesowire Arrays," Science, vol. 293, p. 2227, 2001.
F. A. Lewis, "The Palladium Hydrogen System," Academic Press, 1967.
Eunsongyi Lee, Jun Min Lee, Kye Jin Jeon, and Wooyoung Lee, "Hysteresis Behavior in Electric Resistance-hydrogen Concentration of Pd Thin Films," J. Kor. Inst. Met. & Mater., vol. 47, p. 372, 2009.
Y. Sakamoto, K. Takai, I. Takashima, and M. Imada, "Electrical resistance measurements as a function of composition of palladium - hydrogen(deuterium) systems by a gas phase method," J. Phys.: Condens. Matter, vol. 8, p. 3399, 1996.
Y. Sakamoto, and I. Takashima, "Hysteresis behaviour of electrical resistance of the Pd - H system measured by a gas-phase method," J. Phys.: Condens. Matter, vol. 8, p. 10511, 1996.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.