$\require{mediawiki-texvc}$
  • 검색어에 아래의 연산자를 사용하시면 더 정확한 검색결과를 얻을 수 있습니다.
  • 검색연산자
검색연산자 기능 검색시 예
() 우선순위가 가장 높은 연산자 예1) (나노 (기계 | machine))
공백 두 개의 검색어(식)을 모두 포함하고 있는 문서 검색 예1) (나노 기계)
예2) 나노 장영실
| 두 개의 검색어(식) 중 하나 이상 포함하고 있는 문서 검색 예1) (줄기세포 | 면역)
예2) 줄기세포 | 장영실
! NOT 이후에 있는 검색어가 포함된 문서는 제외 예1) (황금 !백금)
예2) !image
* 검색어의 *란에 0개 이상의 임의의 문자가 포함된 문서 검색 예) semi*
"" 따옴표 내의 구문과 완전히 일치하는 문서만 검색 예) "Transform and Quantization"
쳇봇 이모티콘
안녕하세요!
ScienceON 챗봇입니다.
궁금한 것은 저에게 물어봐주세요.

논문 상세정보

교통약자를 고려한 보도의 경사도와 높이 결정을 위한 실험연구

Experimental Study on the Determination of Slope and Height of Curbs Considering the VRUs

Abstract

PURPOSES : As the population of the mobility handicapped, who are classified as the disabled, the elderly, pregnant women, children, etc., has increased, the voices for guaranteeing their rights have been increasing as well. Thus, the design manuals for roads and sidewalks for the mobility handicapped were developed by the local government, such as the Ministry of Land, Transport, and Tourism, in Seoul City. However, according to the 2013 survey results of the Seoul Metropolitan City, the mobility handicapped still feel uncomfortable with the sidewalks, and particularly request for the improvement of the step and slope of the sidewalk curb. Therefore, in this study, we conducted an empirical experimental study to determine the slope of the sidewalk curb and height of the steps considering the mobility handicapped and analyzed whether there is a statistically significant difference. METHODS : The methodology of this study is an empirical experimental one. In the study, five non-disabled people, 10 wheelchair users, and 10 eye patch and stick users walked about 2-3 min on the sidewalk plates of the sloped type (0%, 5%, 6.3%, 8.3%) and stepped type (0 cm, 1 cm, 3 cm, 6 cm), and their human physiological responses, such as the skin temperature, volume of perspiration on forehead and chest, and heart rate, were measured and recorded. After combining the data, we conducted a nonparametric test, ANOVA, or t-test to determine whether there was a statistically significant difference according to each slope and step type. RESULTS : It was found that for the non-disabled, there was no significant difference in human physiological responses according to the slope and steps of the sidewalk. It can be said that the non-disabled do not feel much physiological discomfort while walking. In the case of the sloped sidewalk plate, the heart rate of the wheel chair users increased when the slope was 6.3%. In the case of the eye patch and stick users, the volume of perspiration on the chest increased at a slope of 5.0%. In general, it is judged that a sidewalk with a slope that is less than 5% does not cause a change in the physiological response. In the case of a stepped sidewalk plate, when 0 cm, 1 cm, and 3 cm were compared for wheelchair users, the amount of forehead perspiration increased from 1 cm. Meanwhile, in the case of the eye patch and stick users, when 0 cm and 6 cm were compared, the amount of perspiration on the forehead and chest as well as the heart rate all increased at 6 cm. Taken together, in the case of wheelchair users, a difference was shown when the height of the step of the sidewalk plate was 1 cm, suggesting that installing it at 0 cm does not cause any physiological discomfort. Moreover, in the case of the eye patch and stick users, when comparing only 0 cm and 6 cm, 0 cm was considered to be suitable, as there was a difference in physiological response at 6 cm. CONCLUSIONS : In this study, we set the human physiological responses such as chest skin temperature, amount of perspiration, and heart rate as evaluation items, and our study was considered to be a meaningful experiment that targeted wheelchair users as well as eye patch and stick users. The validity of the evaluation items was confirmed, as the results of human physiological responses were significant. As for the sidewalk design, according to the experiment result, it is considered that differential application should be implemented according to the type of mobility handicap, rather than uniformly applying a sidewalk step of 2 cm and sidewalk slope of 1/25, which are the current legal standards.

저자의 다른 논문

참고문헌 (0)

  1. 이 논문의 참고문헌 없음

이 논문을 인용한 문헌 (0)

  1. 이 논문을 인용한 문헌 없음

원문보기

원문 PDF 다운로드

  • ScienceON :

원문 URL 링크

원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다. (원문복사서비스 안내 바로 가기)

상세조회 0건 원문조회 0건

이 논문과 연관된 기능

DOI 인용 스타일