In case of favourable irradiation conditions, the ratio of irradiation to the total irradiation went up and then the irradiation increased in the area with high angle of inclination. The study showed that on a clear day with the irradiation of more than 80$[W/m^2]$, the pattern of alterna...
In case of favourable irradiation conditions, the ratio of irradiation to the total irradiation went up and then the irradiation increased in the area with high angle of inclination. The study showed that on a clear day with the irradiation of more than 80$[W/m^2]$, the pattern of alternating current power change in the fixed system was similar with that in the single-axis tracker. On the contrary, in case of unfavourable irradiation conditions, the ratio of diffuse irradiation to the total irradiation went up and then the horizontal irradiation increased. In the demo system, the fixed system, the single-axis tracker and the dual-axis tracker all had low generation power and similar generation pattern with each other. The study showed the generation power varied with the irradiation in the fixed system, while in the single-axis tracker and the dual-axis tracker, the amount of the generation Power variation was much more than the irradiation variation. The demo system was operated from 11:00 AM to 2:00 PM for generating power, during which time, 46[%] to 56[%] of the total generation power was produced. In this study, the generation power was increased by 147[%] in the fixed system, by 136[%] in the single-axis tracker, and by 164[%] in the dual-axis tracker, and the pattern of generation power was similar with the generation power variation in the situation where the irradiation increased by 140[%] in the spring with plenty of insolation. The alternating current power was more sensitive to variation of the irradiation than to that of the surface temperature of a module. The variation of the irradiation had a more positive effect on the generation power than the type of array.
In case of favourable irradiation conditions, the ratio of irradiation to the total irradiation went up and then the irradiation increased in the area with high angle of inclination. The study showed that on a clear day with the irradiation of more than 80$[W/m^2]$, the pattern of alternating current power change in the fixed system was similar with that in the single-axis tracker. On the contrary, in case of unfavourable irradiation conditions, the ratio of diffuse irradiation to the total irradiation went up and then the horizontal irradiation increased. In the demo system, the fixed system, the single-axis tracker and the dual-axis tracker all had low generation power and similar generation pattern with each other. The study showed the generation power varied with the irradiation in the fixed system, while in the single-axis tracker and the dual-axis tracker, the amount of the generation Power variation was much more than the irradiation variation. The demo system was operated from 11:00 AM to 2:00 PM for generating power, during which time, 46[%] to 56[%] of the total generation power was produced. In this study, the generation power was increased by 147[%] in the fixed system, by 136[%] in the single-axis tracker, and by 164[%] in the dual-axis tracker, and the pattern of generation power was similar with the generation power variation in the situation where the irradiation increased by 140[%] in the spring with plenty of insolation. The alternating current power was more sensitive to variation of the irradiation than to that of the surface temperature of a module. The variation of the irradiation had a more positive effect on the generation power than the type of array.
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
문제 정의
따라서 본 논문에서는 이러한 문제점을 해결하기 위해서 2007년 1월 1일부터 2007년 12월 31일까지 1년 동안 실증운전을 통한 종합적인 운전특성 데이터, 태양전지 어레이 출력의 전압 전류, 교류 전력 및 전력량, 일사량 및 모듈의 온도, 외기온도 등 분석기간 동안 수집된 운전 데이터를 이용하여 태양이 태양전지 모듈에 입사되는 각과 발전량 즉 태양전지 어레이 형태와 발전량과의 상관관계를 정량적으로 규명하여 태양광 발전시스템의 설계 및 시공의 최적화가 이루어질 수 있도록 하였다.
본 논문에서는 1년간 계통 연계형태양광 발전시스템을 실증 운전하여 외부조건 이 태양광 발전시스템의 성능에 미치는 영향을 정량적으로 평가 제시하였으며 종합적인 운전 특성을 분석하여 다음과 같은 결과를 얻을 수 있었다.
제안 방법
본 연구에서 일사량의 단위 가 [W/m2] 이 므로 설치 된 태양광 발전의 설치 면적에 대한 일사량과 태양광 발전의 1[m2]의 단위로 환산하여 1[m2]당 태양광 발전에 받는 일사량으로 생산되는 발전량을 비교해야 하나 일사량과 태양광 발전의 상관관계만을 비교 . 분석하였으며 교류전력과 일사량 온도의 상관관계를 비교하기 위해서 l[Wp] 단위로 환산하여 곡선을 비교하였다.
태양광 발전의 상관관계만을 비교 . 분석하였으며 교류전력과 일사량 온도의 상관관계를 비교하기 위해서 l[Wp] 단위로 환산하여 곡선을 비교하였다. 태양전지의 구성 기준은 표 1과 같다.
kr) 자료를 사용하였으며 이때의 일조시간둥은 전라남도를 기준으로 하였고 외기온도, 일조량, 출력전압 및 전류값은 모니터링 결과를 기준으로 하였다. 태양광 발전시스템의 실증시험을 위한 운전 특성 분석을 위해서 태양전지 어레이는 태양전지 모듈 (SHARP NE-Q7E3E, 167[W], 34.6[V], 4.83[A], 12.8[%]) 24개를 연결하여 구성하였으며 INVERTER 는 FRONIUS IG -30t 2500[W] INDOOR TYPE 2대를 연결하여 5[kW]로 구성하여 설치하였다.
태양전지 어레이의 구성형태는 고정식의 경우 경사각이 남향 31[이이고 일축 추적식은 태양전지 어레이가 동에서 서로 태양을 추적하도록 하였으며 양축 추적식은 태양의 위치를 동서남북 모든 방위에서 추적이 가능하도록 프로그램 추적 방식으로 설계 하였고 모니터링 결과는 1년을 기준으로 분석하였다.
대상 데이터
모니터링 기간 동안의 기후조건 확인을 위해 기상청 (www.kma.go.kr) 자료를 사용하였으며 이때의 일조시간둥은 전라남도를 기준으로 하였고 외기온도, 일조량, 출력전압 및 전류값은 모니터링 결과를 기준으로 하였다. 태양광 발전시스템의 실증시험을 위한 운전 특성 분석을 위해서 태양전지 어레이는 태양전지 모듈 (SHARP NE-Q7E3E, 167[W], 34.
성능/효과
것을 알 수 있었다. 또한 모듈의 표면온도의 변화에 따른 교류전력 변화의 추이보다는 일사량의 변화에 따른 교류전력 변화가 더 민감하게 반응함을 알 수 있었으며 일사량의 변화에 따른 발전량은 어레이의 형태에 따라서 일사량이 변화하는 량 보다는 더 많은 발전이 되어지는 결과를 얻을 수 있었다.
알 수 있었다. 또한, 일사량의 변화에 따른 발전량은 고정식의 경우에는 일사량과 거의 유사한 패턴을 보이고 있는 반면, 단축추적식과, 양축 추적식은 일사량이 변화하는 량 보다는 더 많은 발전이 이루어짐을 알 수 있었다. 표 2는 시간별 교류전력의 변화량을 나내는것으로 주요 발전시간은 11시부터 14시까지로 발전량의 46[%?게서 56[%1 까지 발전됨을 알 수 있었다.
상기에서 보는 바와 같이 전력량은 일사량에 비례해서 변화하는 하는 것을 알 수 있었는데, 특히 어레이 형태에 따라서 일사량의 변화 패턴보다 더 많은 발전이 이루어지는 결과를 얻을 수 있었다.
일사량의 변화에 따른 발전량은 고정식의 경우에는 일사량과 거의 유사한 패턴을 보이고 있는 반면 단축 추적식과, 양축 추적식은 일사량이 변화하는 량 보다는 더 많은 발전이 이루어짐을 알 수 있었고 주요 발전시간은 U시부터 14시까지로 발전량의 46[%]에서 56[%]까지 발전됨을 알 수 있었으며, 일사량이 많은 봄에는 일사량이 140[%] 증가하는 패턴과 유사하게 고정식은 147[%], 단축 추적식은 136[%], 양축추적식은 164[%] 발전량이 증가하는 것을 알 수 있었다. 또한 모듈의 표면온도의 변화에 따른 교류전력 변화의 추이보다는 일사량의 변화에 따른 교류전력 변화가 더 민감하게 반응함을 알 수 있었으며 일사량의 변화에 따른 발전량은 어레이의 형태에 따라서 일사량이 변화하는 량 보다는 더 많은 발전이 되어지는 결과를 얻을 수 있었다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.