NTIS 바로가기방사선방어학회지 = Radiation protection : the journal of the Korean association for radiation protection, v.34 no.3, 2009년, pp.107 - 114
서희 (한양대학교 원자력공학과) , 이세형 (울산대학교 의과대학 서울아산병원 방사선종양학과) , 박진형 (한양대학교 원자력공학과) , 김찬형 (한양대학교 원자력공학과) , 박성호 (울산대학교 의과대학 서울아산병원 방사선종양학과) , 이주한 (중앙대학교 물리학과) , 이춘식 (중앙대학교 물리학과) , 이재성 (서울대학교 핵의학교실)
A Compton camera, which is based on Compton kinematics, is a very promising gamma-ray imaging device in that it could overcome the limitations of the conventional gamma-ray imaging devices. In the present study, the image quality of a rotating Compton camera was evaluated by using 4-D Monte Carlo si...
X-5 Monte Carlo Team. MCNP-A General Monte Carlo N-Particle Transport Code, Version 5. LA-UR-03-1987, Los Alamos National Laboratory, 2005
Forster RA, Cox LJ, Barrett RF, et al. MCNP Version 5. Nucl. Instr. Meth. B 2004;213:82-86
Hendricks JS, et al. MCNPX 2.3.0 User's Guide(Unrestricted Distribution Version). LA-UR-02-2607, Los Alamos National Laboratory, 2002
Hendricks JS, McKinney GW, Durkee JW, et al. MCNPX,Version 26c. LA-UR-06-7991, Los Alamos NationalLaboratory, 2006
Agostinelli S, Allison J, Amako K, et al. GEANT4-A simulation toolkit. Nucl. Instr. Meth. A 2003;506(3):250-303
Allison J, Amako K, Apostolakis J, et al. Geant4 Developments and Applications. IEEE Trans. Nucl. Sci.,2006;53(1):270-278
Kawrakow I and Rogers DWO. The EGSnrc code system:Monte Carlo simulation of electron and photon transport. NRCC PIRS-701, 2006
Basaglia T, Bell ZW, Dressendorfer PV, Larkin A, andPia MG. Writing Software or Writing Scientific Atricles? IEEE Trans. Nucl. Sci. 2008;55(2):671-678
Lee SH, Seo H, Park JH, Park SH, Lee JS, Lee JH, Lee CS,and Kim CH. CIS: a GUI-based Software System for MonteCarlo Simulation of Compton Camera. Nucl. Technol. (in press)
Schonfelder V, Hirner A, and Schneider K. A telescope for soft gamma ray astronomy. Nucl. Inst. Meth. 1973;107:385-394
Schoenfelder V, et al. Instrument description and performance of the imaging gamma-ray telescope COMPTEL aboard the Compton gamma-ray observatory. Astrophys. J. Suppl.Ser. 1993;86:657-692
Bloser PF, Ryan JM, McConnel ML, et al. The MEGA Project for Medium Energy Gamma-ray Astronomy. Chin.J. Astron. Astrophys. 2006;6(S1):388-392
Brandt S, Budtz-Jogensen C, Lund N, et al. X-ray observations of the Crab Pulsar and Nebula with JEM-X on INTEGRAL. Astronomy & Astrophysics 2003;411:L433-L436
Bhattacharya D, O'Neill TJ, AkyuA, Samimi J, Zych AD. Prototype TIGRE Compton $\gamma$ -ray balloon-borne telescope. New Astronomy Review 2004;48:287-292
Todd RW, Nightingale JM and Everett DR. Proposed Gamma Camera. Nature 1974;251:132-134
Singh M, Doria D. An Electronically Collimated Gamma Camera for Single Photon Emission Computed Tomography. Part II: Image reconstruction and preliminary experimental measurements. Med. Phys. 1983;10:428-435
Llosa G, Bernabeu J, Burdette D, et al. Last Results of a First Compton Probe Demonstrator. IEEE Trans. Nucl.Sci. 2008;55(3):936-941
Watanabe S, Tanaka T, Watanabe S, et al. Performance Study of Si/CdTe Semiconductor Compton Telescopes with Monte Carlo Simulation. Nucl. Instr. and Meth. A2007;579:878-885
Kabuki S, Hattori K, Kohara R, et al. Development of Electron Tracking Compton Camera using micro pixel gas chamber for medical imaging. Nucl. Instr. and Meth. A2007;580:1031-1035
Vetter K, Burks M, Cork C, et al. High-sensitivityCompton Imaging with Position-sensitive Si and GeDetectors. Nucl. Instr. and Meth. A 2007;591:363-366
Du YF, He Z, Knoll GF, Wehe DK, Li W. Evaluation of a Compton scattering camera using 3-D position sensitive CdZnTe detectors. Nucl. Instr. and Meth. A 2001;457:203-211
Motomura S, Kanayama Y, Haba H, Watanabe Y and Enomoto S. Multiple molecular simultaneous imaging in a live mouse using semiconductor Compton camera. J.Anal. At. Spectrom. 2008;23:1089-1092
Watanabe S, Takeda S, Ishikawa S, et al. Development of semiconductor imaging detectors for a Si/CdTe Compton camera. Nucl. Instr. and Meth. A 2007;579:871-877
Leblanc JW, Clinthorne NH, and Hua CH, et al. C-SPRINT:A prototype Compton Camera system for low energy gammaray imaging. IEEE Trans. Nucl. Sci. 1998;45:943-949
Park SJ, Rogers WL, Huh S, et al. Performance evaluationof a very high resolution small animal PET imager usingsilicon scatter detectors. Phys. Med. Biol. 2007;52:2807-2826
$\c{C}$ onka-Nurdan T, Nurdan K, Constantinescu F, et al.Impact of the Detector Parameters on a Compton Camera.IEEE Trans. Nucl. Sci. 2002;49(3):817-821
$\c{C}$ onka-Nurdan T, Nurdan K, Walenta AH, et al. First Results on Compton Camera Coincidences With the Silicon Drift Detector. IEEE Trans. Nucl. Sci. 2005;52(5):1381-1385
Lee JH, Kim NY, Lee CS and Jang ZH. Development of the Multi-purpose Gamma-ray Detection System Consisting of a Double-sided Silicon Strip Detector and a25-segmented Germanium Detector. Nucl. Phys. A2005;758:150-153
Seo H, An SH, Kim JK, Kim CH. Monte Carlo Study of aDouble Scattering Compton Camera with GEANT4. Nucl.Instr. and Meth. A 2007;580:314-317
Wilderman SJ, Fessler JA, Clinthorne NH, LeBlanc JW,and Rogers WL. Improved modeling of system responsein list mode EM reconstruction of Compton scatter camera images. IEEE Trans. Nucl. Sci. 2001;48(1):111-116
Hebert T, Leahy R, and Singh M. Three-dimensional maximum likelihood reconstruction for an electronicallycollimated single photon-emission imaging system. J. Opt.Soc. Amer. A 1990;7(7):1305-1313
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.