최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Journal of the Ergonomics Society of Korea = 大韓人間工學會誌, v.21 no.1, 2002년, pp.95 - 112
Two experiments were carried out to compare the suitability in visual tasks between cathode-ray tube (CRT) and thin film transistor-liquid crystal display (TFT-LCD). In the first experiment, the subjects were requested to detect pre-assigned target words or icons among distracters presented under ti...
이종덕 외,디스플레이 공학 I, 청범출판사: 서울,2000
이상훈,추성훈,'FPD에 대응한 CRT의 최근기술동향 및 전망',한국정보디스플레이학회지,2(5), 12-19, 2001
이이상,‘액정 TV의 현황 및 전망’,한국정보디스플레이학회지,2(1), 25-29, 2001
장진,‘TFT-LCD 산업 경쟁력 향상 방안’,한국정보디스플레이학회지,2(1), 9-16, 2001
한수덕,‘CRT 시장과 기술,그리고 향후 전망‘,한국정보디스플레이학회지,2(5), 6-11, 2001
松本iE一, 전자 디스플레이,성안당: 서울, 1998
中村芳知 등,‘高輝度マルチメディアブラウン管(17形 Diamondtron M12管) の開發',月刊ディスプレイ 01 7月?,23-28, 2001
Bastien J.M.C, et. al., 'The Ergonomic Criteria and the ISO/DIS 9241-10 Dialogue Principles: A Pilot Comparison in an Evaluation Task', Interacting with Computers, 11, 299-322, 1999
Besuijen, K. and Spenkelink G.P.J,'Standardizing Visual Display Quality', Displays, 19, 67-76, 1998
Boschman M.e. and Roufs, J.A.J., 'TextQuality Metrics for Visual Display Units: II. An Experimental Survey', Displays, 18, 45-64, 1997
Chi, C'F, and Lin, F.T., 'A Comparison of Seven Visual Fatigue Assessment Techniques in Three Data-Acquisition VDT Tasks', Human Factors, 40(4), 577-500, 1998
Grandjean, E., Ergonomics in Computerized Offices, Taylor & Francis: London, 1987
Lindfors, M., 'Accuracy and Repeatability of the ISO 9241-7 Test Methods', Displays, 19, 3-16, 1998
MacKenzie, I.S. et. al., 'Effects of Output Display and Control-Display Gain on Human Performance m Interactive Systems', Behaviour and Infonnation Technology, 13(5), 328-337, 1994
Menozzi, M et. al., 'CRT versus LCD: A Pilot Study on Visual Performance and Suitability of Two Display Technologies for Use in Office Work', Displays, 20, 3-10, 1999
Menozzi, M et. al., 'CRT versus LCD: Effects of Refresh Rate, Display Technology and Background Luminance in Visual Performance', Displays, 22, 79-85, 2001
Roufs, J,A.J, and Boschman M.C., 'Text Quality Metrics for Visual Display Units: I. Methodological Aspect', Displays, 18, 37-43, 1997
Saito, S. et. al., 'Physiological Indices of Visual Fatigue due to VDT Operation: Pupillary Reflexes and Accommodative Responses', Industrial Health, 32, 57-66, 1994
Saito, S. et. al., 'Visual Comfort using Different VDT Screens', International Journal of Human-Computer Interaction. 5(4), 313-323, 1993
Sanders, MS. and McCormick, E.J., Human Factors in Engineering and Design, 7th Ed.. McGraw-Hill. 1993
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.