Recently, many high-rise reinforced concrete(RC) bearing-wall structures of multiple uses have been constructed, which have the irregularities of weak(or soft) story and torsion at the lower stories simultaneously. The study stated herein was performed to investigate seismic performance of such a hi...
Lee et al., “Shaking Table Tests of a High RC Bearing-Wall Structrure with Bottom Piloti Stories,” Journal of Asian Architecture and Building Engineering, Vol. 1 No. 1, 2002, pp. 47-54.
Lee et. al, “Effect of Shear Walls on Seismic Performence of Piloti-Type High-Rise RC Bearing-Wall Structures,” Structural Engineers World Congress 2002, 2002, Yokohama.
De la llera, J. C. and Chopra, A. K., “Understanding the inelastic seismic behaviour of asymmetric-plan buildings,” Earthquake Engineering and Structural Dynamics, Vol. 24, 1995, pp. 549-572.
Tso, W. K. et al., “Design of torsionlly unbalanced structural systems based on code provisions 1: ductility demand,” Earthquake Engineering and Structural Dynamics, Vol. 21, 1992, pp. 609-627.
Rutenberg, A. et al., “Nonlinear response of asymmetric building structures; a state of the art review,” Nonlinear Seismic Analysis and Design of Reinforced Concrete Buildings, Elsevier Applied Science, pp. 281-305.
Chandler, A. M. et al. “Evaluation of factors influencing the inelastic seismic performance of torsionally asymmetric buildings,” Earthquake Engineering and Structural Dynamics, Vol. 20, 1991, pp. 87-95.
대한건축학회, 건축물 하중기준 및 해설, 대한건축학회, 2000.
Hiroshi Hosoya, “Shaking Table Tests of Three-Dimensional scale Models of Reinforced Concrete High-Rise Frame Structures with Wall Columns,” ACI Structural Journal, Vol. 92, No. 6, 1995, pp. 765-780.
Zia, P., Principles of Model Analysis, ACI SP-24, Michigan, 1970, pp. 19-39.
건설교통부, “내진설계기준연구(II)-내진설계성능기준과 경제성평가,” 건설교통부, 1997.
International Code Council(ICC), International Building Code 2000, ICC.