최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기센서학회지 = Journal of the Korean Sensors Society, v.13 no.5, 2004년, pp.356 - 362
장수원 (경북대 전자공학과) , 정영희 (경북대 전자공학과) , 박진호 (아주대학교 분자과학기술학과) , 김재호 (아주대학교 분자과학기술학과) , 권대혁 (경일대학교 전자정보통신학부) , 이승하 (경북대학교 전자전기공학부) , 강신원 (경북대학교 전자전기공학부)
In this study, we developed the measuring system based on light addressable potentiometric sensor for the quantitative analysis of penicillin that is very important element in medicine and pharmacy, clinic. It is investigated the response characteristics by enzyme reaction with penicillinase. First,...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
S. Caras and J. Janata, 'Field-effect transistor sensitive to penicillin', Anal. Chem., vol. 52, pp. 1935-1937, 1980
A. Poghossian, M. J. Schoning, P. Schroth, A. Simonis, and H. Luth, 'An ISFET-based penicillin sensor with high sensitivity, low deection limit and long lifetime', Sensors and Actuators B., vol. 76, pp. 519-526, 2001
A. P. Soldatkin, J. Montoriol, W. Sant, X. Martelet, and N. Jaffrezic-Renault, 'A novel urea sensitive biosensor with extended dynamic range based on recombination urease and ISFETs', Biosensors and Bioelectronics, vol. 19, pp. 131-135, 2003
A. Seki, S. I. Ikeda, I. Kubo, and I. Karube, 'Biosensors based on light-addressable potentiometric sensors for urea, penicillin. and glucose', Analytica chirnica Acta, vol. 373, pp. 9-13, 1998
Frank Hafner, 'Cytosensor microphysiometer : technology and recent applications', Biosensors and Bioelectronics, vol. 15, pp. 149-158, 2000
S. Inoue, M. Nakao, T. Yoshinobu, and H. Iwasaki, 'Chemical-imaging sensor using enzyme', Sensors and Actuators B., vol. 32, pp. 23-26, 1996
K. Dill, L. H. Stanker, and C. R. Young, 'Detection of salmonella in poultry using a silicon chip-based biosensor', J. Biochem. Biophys. Methods., vol. 41, pp. 61-67, 1999
J. I. Anzai, M. Shimada, H. Fu, and T. Osa, 'Fabrication of potentiometric enzyme sensors based on a pH-sensitive polymer-coated Ag electrode', Chem. Pharm. Bull., vol. 35, pp. 4568-4573, 1987
C. Eppelsheim, R. Aubeck, and N. Hampp, 'Comparison of potentiometric enzyme sensors for urea and penicillin-G: differential thick-film sensors versus classical electrodes', J. Memb. Sci., vol. 100, pp. 131-137, 1995
W. Hbel, A. Papperger, and J. Polster, 'Penicillinase optodes: substrate determinations using bath, continuous flow and flow injection analysis operation conditions', Biosens. Bioelectron. vol. 7, pp. 549-557, 1992
B. G. Healey, L. Li, and D. R. Walt, 'Multianalyte biosensors on optical imaging bundles', Biosens. Bioelectron., vol. 12 pp. 521-529, 1997
J. Lui, L. Liang, G. Li, R. Han, and K. Chen, ' $H^+$ ISFET-based biosensor for determination of penicillin G', Biosens. Bioelectron., vol. 13, pp. 1023-1028, 1998
J. Liu and G. Li, 'Application of biosensors for diagnostic analysis and bioprocess monitoring', Sens. Actuators B., vol. 65, pp. 26-31, 2000
G. Dean, J. Hafeman, W. Parce, and H. M. McConnel, 'Light addressable potentiometric sensor for biochemical systems', Science., vol. 240, pp. 1182, 1988
장수원, 고광락, 강신원, 'Electrolyte/ $Si_3N_4/SiO_2/Si$ 구조의 LAPS 제작 및 pH 응답특성', 한국전기화학회, pp. 40-44, 1998
M. Lambrechts, and W. Sansen, 'Biosensors : Microelectrochemical devices, Institute of Physics Publishing Bristol', Philadelphia and New York, pp. 20-75, 1992
A. Poghossian, M. Thust, M. J. Schoning, M. Muller-Veggian, P. Kordos, and H. Luth, 'Crosssensitivity of a capacitive penicillin sensor combined with a diffusion barrier', Sensor and Actuators B., vol. 68, pp. 260-265, 2000
Brain, R. Eggins, 'Chemical sensors and biosensors', John Willy & Sons, LTD
Luc Bousse, J. C. Owicki, and J. Wallace Parce, 'Biosensors with microvolume reaction chamber', Chemical Sensor Technology., vol. 4, pp. 145-166, 1992
T. Yoshinobu, H. Ecken, A. B. Md. Ismail, H. Iwassaki, H. Lth, and M. J. Schning, 'Chemical imaging sensor and its application to biological systems', Electrochimic Acta., vol. 47, pp. 259-263, 2001
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.