최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기韓國環境衛生學會誌 = Korean journal of environmental health society, v.30 no.2 = no.78, 2004년, pp.92 - 97
양원호 (대구가톨릭대학교 산업보건학과) , 김대원 (대구가톨릭대학교 환경과학) , 정문호 (서울대학교 보건대학원 환경보건학) , 양진섭 (㈜이앤비 코리아 환경연구) , 박기선 (㈜이앤비 코리아 환경연구소)
Three methods for VOCs emissions control in indoor air are reduction at the source, ventilation between indoor and outdoor, and removal. The best alternative should be to replace highly emitting sources with sources having low emissions, but the pertinent information on VOCs is not always available ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Molhave, L. and Krzyanowski, M. : The right to healthy indoor air: status by 2002. Indoor Air, 13, 50-53, 2003
Jones, A. P. : Indoor air quality and health. Atmospheric Environment, 33, 4535-4564, 1999
US EPA : Unfinished business: a comparative assessment of environmental problems. EPA report EPA-230/2-87-025, 1987
US EPA : Characterizing air emissions from indoor sources. EPA Report EPA/600/F-95 /005, 1995
Vincent, D., Annesi, I., Festy, B. and Lambrozo, J. : Ventilation system, indoor air quality, and health out-comes in parisian modem office workers. Environ-mental Research, 75, 100-112, 1997
Skillas, G., Huglin, C. and Siegmann, H. C. : Deter-mination of air exchange rates of rooms and deposition factors for fine panicles by means of photoelectric aerosol sensors, Indoor Built Environment, 8, 246-254, 2000
Yang, W. H., Lee, K. Y. and Chung, M. H. : Char-acterization of indoor air quality using multiple mea-surements of nitrogen dioxide. Indoor Air, In Press, 2004
Sparks, L. E., Molhave, L. and Dueholm, S. : Source testing and data analysis for exposure and risk assess-ment of indoor pollutant sources. ASTM STP 1287, American Society for Testing and Materials, 367-375, 1996
김신도 : 실내공기질 관리 및 측정. 한국대기환경학회 실내공기질 분과회 세미나, 102-115, 2003
Bae, H., Yang, W. and Chung, M. : Potential exposureand traffic contribution to indoor air quality of shoe-stalls near busy road in Korea. The Science of the Total Environment, 323, 99-105, 2004
Spicer, C. W., Coutant, R. W., Ward, G. F. and Joseph, D. W. : Rates and mechanism of $NO_2$ removal from indoor air by residential materials. Environmental International, 15, 643-654, 1989
Jacoby, W. A., Blake, D. M., Fennell, J. A., Boulter, J. E., Vargo, L. M., George, M. C. and Dolberg, S. K. : Heterogeneous photocatalysis for control of volatile organic compounds in indoor air. Journal of the Air & Waste Management Association, 46, 891-898, 1996
Bhowmic, K. M. and Semmens, M. J. :Batch studies on closed loop air stripping process. Water Res., 28(9), 2011-2020, 1995
Fu, X., Zeltner, W. A. and Anderson. M. A. : The gas-phase photocatalytic mineralization of benzene on porous titania-based catalysts, Applied CataIysis B, Environment, 6, 209-224, 1995
장성기 : 실내공기질 공정시험방법 작성 방향. 대한주택공사 주택도시 연구원 2003년 겨울호, 59-69, 2003
이병용, 김성욱, 정석진 : VOC 물질중 에탄올 광분해 반응을 위한 Ti $O_2$ ,촉매의 제조 변수 고찰. 한국대기환경학회, 17(4), 363-370, 2001
Matralis, H. K., Ciardelli, M., Ruwet, M. and Grange, P. : Vanadia catalysts supported on mixed Ti $O_2$ -A $l_2O_3$ supports: Effect of composition on the structure and acidity. Journal of Catalysis, 157, 368-379, 1995
Yamashita, H., Ichihashi, Y., Harada, M., Stewart, G., Fox, M. A. and Anpo, M. : Photocatalytic degrada-tion of l-octanol on anchored titanium oxide and on Ti $O_2$ Power catalysts, Journal of Catalysis, 158, 97-101, 1996
Obbe, T. N. and Brown, R. T. : Ti $O_2$ Photocatalysis for indoor air applications: effects of humidity and trace contaminant levels on the oxidation rates of formaldehyde, toluene, and 1,2-butadiene. Environ-mental Science & Technology, 29(5), 1223-1231, 1995
Chapuis, Y., Klavana, D., Guy, C. and Kirchnerova, J. : Photocatalyst oxidation of volatile organic Com-pounds using fluorescent visible light. Journal of the Air & Waste Management Association, 52, 845-854, 2002
※ AI-Helper는 부적절한 답변을 할 수 있습니다.