Non-invasive blood glucose measurement from mouse tail was performed by near-infrared (NIR) spectroscopy. Three groups; normal, type I diabetes (insulin dependent diabetes mellitus, IDDM), type II diabetes (non-insulin dependent diabetes mellitus, NIDDM) group, were studied over a 10 weeks period wi...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Zhang, L., Small, G. W. and Arnold, M. A. : Calibration standardization algorithm for partialleast-squares regression: Application to the determination of physiological levels of glucose by near-infrared spectroscopy. Anal. Chem. 74 (2002)
Siesler H. W., Ozaki, Y., Kawata, S. and Heise, H. M. : Near-infrared spectroscopy : Principes, Instruments, Applications, WILEY-VCH (2002)
Maruo, K., Tsurugi, M., Tamura, M. and Ozaki,Y.: in vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy. Applied Spectroscopy 57 (2003)
Malin, S. F, Ruchti, T. L., Blank, T. B., Thennadil, S. N. and Monfre, S. L. : Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy. Clinical Chemistry 45 (1999)
Gabriely, I., Woznik,R., Aharon, Y., Melvorach, M. and Shamoon, H. : Transcutaneous glucose measurement using near-infrared spectroscopy during hypoglycemia. Diabetes Care 22 (1999)
Muller,U. A., Mertes, B., Fischbacher, C., Jagernan, K. U. and Danzer, K. : Non-invasive blood glucose monitoring by means of near infrared spectroscopy : methods for impoving the reliability of the calibration models, Artificial Pancreas and Related Technology in Diabetes and Endocrinology 20 (1997)
Edmund R. Malinowski, Factor Analysis in Chemistry, A Wiley-Interscience Publication, 2nd Edition (1991)
Jagemann, K. U., Fischbacher C., Danzer, K., Muller, U. A. and Mertes, B. : Application of near-infrared spectroscopy for non-invasive determination of blood/tissue glucose using neural network. Z. Phys. Chem. 191S (1995)
Fischbacher, C., Jagemann, K. U., Danzer K., Muller, U. A., Papenkrodt, L. and Schuler, J. : Enhancing calibration models for non-invasive near-infrared spectroscopic blood glucose determinations. Fresenius J. Anal. Chem. 359 (1997)
Danzer, K., Fischbacher, C. H., Jagemann , K. U. and Reichelt, K. J. : Near-infrared diffuse reflection spectroscopy for non-invasive blood-glucose monitoring. LEOS Newslett 12 (1998)
Muller U. A., Mertes, B., Fischbacher C. E, Jagemann , K. U. and Danzer, K. : Non-invasive blood glucose monitoring by means of new infrared spectroscopic methods for improving the reliability of the calibration models. Int. f. Artif. Organs 20(1997)
Monfre, S. L., Blank, T. B., Ruchti, T. L. and Thennadil, S. : Multi-tier method of classifying sample spectra for noninvasive blood analyte prediction. US 6512936 B1 (2003)
Ha, B. J. : The study on the biological activity in alloxan-induced diabetes mice. J. of Nat. Sci. of Women's Univ., 3(1997)
Szkudelski, T. : The mechanism of alloxan and streptozotocin action in B cells of the rat pancreas. Physiol. Res. 50, 536(2001)
Makimura, H., Mizuno, T. M., Isoda, E, Beasley, J.,Silverstein, J. H. and Mobbs, C. V. : Role of glucocorticoids in mediating effects of fasting and diabetes on hypothalamic gene expression. BMC Physiol. 3 (2003)
Hoening, M. and Ferguson, D. C. : Diagnostic utility of glycosylated hemoglobin concentrations in the cat. Domestic Animal Endocrinology 16 (1999)
Kang, N., Woo, Y.-A., Cha, B.-S., Lee, H.-C. and Kim, H.-J. : Non-invasive blood glucose measurement by a portable near infrared (MIR) system. Yakhak Hoeji 46 (2002)
Blanco, M., Coello, J., Iturriaga, H., Maspoch, S. and Pezuela, C. de la : Near-infrared spectroscopy in the pharmaceutical industry. Analyst 123 (1998)
Hazen, K. H., Arnold, M. A. and Small, G. W. : Measurement of glucose and other analytes in undiluted human serum with near-infrared transmission spectroscopy. Applied Spectroscopy 48 (1994)
Kang, N. : Development of noninvasive blood glucose measurement by portable near infrared spectrometer. master's thesis (2002)
※ AI-Helper는 부적절한 답변을 할 수 있습니다.