최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기대한치과보철학회지 = The journal of Korean academy of prosthodontics, v.42 no.2, 2004년, pp.192 - 209
Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Par...
Binon PP. Implants and components:Entering the new millennium. Int J Oral Maxillofac Implants 2000: 5: 76-94
Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces, J Prosthet Dent 2001:86:24-32
Sakaguchi RL, Borgersen SE. Nonlinear finite element contact analysis of preload dental implant components. Int J Oral Maxilofac Implant. 1993: 655-661
Brunski JE, Hipp JE. In the forces on endosteal implant: A measurement system and biomechanical consideration. J Prosthet Dent 1984:51 :82
Sones AD. Complication with osseointegrated implants. J Prosthet Dent 1989: 62:581-585
Boggan RS, Strong TA, Misch CE. Bidez MW. Inf1uence of hex geometry and prostetic table width on statig and fatigue strength of dental implants. J Prosthet Dent 1999: 82: 436-440
Abrahamsson I, Berglundh T. Lindhe J. Soft tissue response to plaque formation at different implant systems. A comparative study in the dog. Clin Oral Implants Res 1998:9:73-79
Quirynen M, Bollen CML. Eyssen H, van Steenberghe D. Microvial penetration along the implant components of the Branemark system. An in vitro study. Clin Oral Implants Res 1994:5:239-244
Gross M. Abramovich I. Weiss EI. Microleakage at the abutment- implant interface of osseointegrated implants. Int J Oral Maxillofac Implants 1999: 14:94-100
Besimo CE, Guindy JS, Lewetag D. Meyer J. Prevention of bacterial leakage into and from prefabricated screw-retained crowns on implants in vitro. Int J Oral Maxillofac Implants 1999: 14:654-660
Becker W. Becker BE. Replacement of maxillary and mandibular molars with single endosseous implant restorations: A retrospective study. J Prosthet Dent 1995:80:184-192
Jemt T, Laney WR, Harris D. Henry, PJ. Krogh P, Polizzi G. Osseointegrated implants for single tooth replacement. A 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants 1991 :6:29-36
Levine RA, et al. A multicenter retro-spective analysis of ITI implant system used for single-tooth replacements: Preliminary results at six or more months of loading. Int J Oral Maxillofacial Implants 1997: 12:237-242
Norton MR. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res 1997:8:290-298
Norton MR. Assessment of cold welding properties of internal conical interface two commercially available implant system. J Prosthet Dent 1999:81:159-166
Burguette RL, Johns MR, King TB, Patterson EA. Tightening characteristic for screwed joint in osseointegrated dental implant. J Prosthet Dent 1994: 71: 592-599
Binon PP. Evaluation of three slip fit hexagonal implants. Implant Dent 1996: 5:253-248
Binon PP. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996: 9: 149-152
Binon PP, McHugh MJ. The effect of eliminating implant/ abutment rotation-al misfit on screw joint stability. Int J Prosthodont 1996: 9:511-519
Byren D, Houston F, Cleary R. Claffey N. The fit of cast and premachined implant abutments. J Prosthet Dent 1998:80:184-192
Carr AB, Brunski JB, Hurley E. Effect of fabrication, finishing, and polishing procedures on preload in prostheses using conventional gold and plastic cylinders. Int J Oral Maxillofac Implants 1996: 11:589-598
Carr AB, Brunski JB. Hurley E. The effect of finishing and polishing techniques in implant cylinder preload: 9th Annual Meeting of the Academy of Osseointergration (Abstract). Int J Oral Maxilofac Implants 1995: 10: 123-124
Kim NH, Chung CB, Son MK, Back DB, A study on the fit of the implant-abutment-screw interface. J Korean Acad Prosthodont 2003:41: 503-518
Sutter F, Schroeder A. et al. The new concept of ITI hollow- cylinder and hollow screw implants : Part 1. Engineering and design. Int J Oral Maxilofac Implant. 1988:3: 161-172
Beat R. Mechanics of the implant-abutment connection: An 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000: 15: 519-526
Ekfeldt A. Clinical evaluation of single-tooth restorations supported by osseointegrated implants: A retrospective study, Int J Oral Maxilofac Implants 1994:179-183
Krennmair G. Schmidinger S, Waldenberger O. Single-tooth replacement with frialit2 system: A retrospective clinical analysis of 146 implants. Int J Oral Maxilofac Implanst. 2002: 17: 78-85
Persson LG. Bacterial colonization on internal surfaces of Branemark system implant components. Clin Oral Impl Res 1996: 7: 90-9
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.