최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기대한치과보철학회지 = The journal of Korean academy of prosthodontics, v.42 no.2, 2004년, pp.238 - 247
Statement of problem: Major objective in making on implant-supported prosthesis is the production of superstructure that exhibits a passive fit when connected to multiple abutments. One requirement to ensure passive fit is to make an accurate impression. Purpose : The purpose of this study was to co...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Adell R. Lekholm D, Rockler B. Bransmark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981: 10:387-416
Han ET. Kim YS. Kim CW, A comparative analysis of the accuracy of implant impression techniques by using strain gauge. J Korean Academy of Prosthodontics 1995:33:539
Burguete RL. Johns RB. King T. Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent 1994: 71: 592-9
Misch CE. Contemporary implant dentistry. Mosby Year Book. Inc. St. Louis 1993
Zarb GA. Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants. The Tronto study. Part III : Problem and complications encountered. J Prosthet Dent 1990:64: 185
Humphries RM. Yaman P. Bleom TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990:5:331-6
Rangert B. Jemt T. Jorneus L. Forces and movements on Branomark implants. Int J Oral Maxillofac Implants 1990:4:241-7
Bransmark PI. Zarb GA. Albrektsson T. Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry. Chicago, Quintessence Publ Co 1985: 117-28
Branarnark PI. Zarb GA. Albreksson T. Tissue-integrated prostheses. Quintessence publish Company 1990:233-40
Sones AD. Complications with osseointegrated implants. J. Prosthet Dent 1989:62:581-5
Barrett MG. de Rijk WG. Burgess JO. The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 1993: 2: 75-82
Assif D. Marshak B. Schmidt A. Accuracy of implant impression techniques. Int J Oral Maxillofac Implants 1996:11:216-22
Carr AB. A comparison of impression techniques for a five implant mandibular model. Int J Oral Maxillofac Implants 1991 :6:448-55
Assif D. Fenton A. Zarb G. Schmitt A. Comparative accuracy of implant impression procedures. Int J Periodont Rest Dent 1992: 12: 113-21
Phillips KM. Nicholls JI, Ma T. Rubenstein J. The accuracy of three implant impression technique: A three-dimensional onal analysis. Int. J. Oral Maxillofac Implant 1994:9:533-40
Rodney J. Johansens R. Harris W. Dimensional accuracy of two implant impression copings. J Dent Res 1991:70: 385
Misch CE, Density of bone: effect on treatment plans. surgical approach. healing, and progressive loading. Int J Oral Maxillofac Implants 1995: 10: 303-11
Worthington P. Bolendef CL. Taylar TD. The Swedish system of osseo-integrated implants: problems and complications encountered during a 4-year trial period. Int J Oral Maxillofac Implants 1987:77-84
Sellers GC. Direct assembly framework for osseointegrated implant prosthesis. J. Prosthet Dent 1989 :62: 662-8
Clelland NL. Carr AB. Gilat A. Comparison of strains transferred to a bone simulant between as-cast and post-soldered implant frameworks for a five-implant-supported fixed prosthesis. J Prosthodont 1996:5(3): 193-200
Jemt T. In vivo measurements of precision fit involving implant-supported prostheses in the edentulous jaw. Int J Oral Maxillofac Implants 1996:11:151-8
Henry PJ. An alternative method for the production of accurate casts and occlusal records in osseointegrated implant rehabilitation. J Prosthet Dent 1987:58:694-7
Tautin FS. Impression making for osseointegrated denture. J Prosthet Dent 1985:54:250-1
Liou AD. Nicholls JI, Yuodelils R, Brudvik JS. Accuracy of replacing three tapered transfer impression copings in two elastomeric impression material. Int J Periodont Rest Dent 1993:6:377-83
Wee AG. Comparison of impression materials for direct multi-implant impressions. J Prosthet Dent 2000: 83: 323-31
Craig RG. Restorative Dental Materials. St Louis. CV Mosby Co. 1989:293-346
Spector M. Donovan TE. Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990:63:444-7
Carr AB. Master J. The accuracy of implant verification casts compared with casts produced from a rigid transfer coping technique. J Prosthet Dent 1996:5:248-52
Lorenxoni M. Pertl C. Penkner K. Polansky R, Sedaj B. Wegscheider WA. Comparisonof the transfer precision of three different impression materials in combination with transfer caps for the Frialit-2 system. Journal of Oral Rehabilitation 2000:27:629-38
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.