NTIS 바로가기大韓機械學會論文集. Transactions of the Korean Society of Mechanical Engineers. B. B, v.31 no.1 = no.256, 2007년, pp.91 - 98
박차식 (고려대학교 대학원 기계공학과) , 장용희 (고려대학교 대학원 기계공학과) , 이영수 (한국에너지기술연구원 미활용지열연구센터) , 김용찬 (고려대학교 기계공학과)
Air-conditioners use a spirally coiled capillary tube as an expansion device to enhance compactness of the unit. However, most empirical correlations in open literature were developed for straight capillary tubes without considering coiled effects on the mass flow rate. The objectives of this study ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Erth, R. A., 1970, 'Two-Phase Flow in Refrigeration Capillary Tube : Analysis and Prediction,' Ph. D. Thesis., The Univ. of Purdue
Goldstein, S. D., 1981, 'A Computer Simulation Method for Describing Two-Phase Flashing Flow in Small Diameter Tubes,' ASHRAE Trans., Vol. 87, pp. 51-60
Li, R. Y., Lin, S. and Chen, Z. H., 1990, 'Numerical Modeling of Thermodynamic Non-Equilibrium Flow of Refrigerant Through Capillary Tubes,' ASHRAE Trans., Vol. 96, Part 1, pp. 542-549
Kuehl, S. J. and Goldschmidt, V. W., 1991, 'Modeling of Steady Flows of R-22 Through Capillary Tubes,' ASHRAE Trans., Vol. 97, Part 1, pp. 139-148
Yufeng, Z., Guobing, Z., Hui, X. and Jing, C., 2005, 'An Assessment of Friction Factor and Viscosity Correlations for Model Prediction of Refrigerant Flow in Capillary Tubes,' Int. J. Energy Res., Vol. 29, pp. 233-248
Bolstad, M. and Jordan, R. C., 1948, 'Theory and use of the Capillary Tube Expansion Devices,' Refrigerating Engineering, Vol. 29, No. 6, pp. 519-523
Wolf, D. A., Bittle, R. R. and Pate, M. B., 1995, 'Adiabatic Capillary Tube Performance with Alternative Refrigerants,' ASHRAE Final Report No. RP-762
Melo, C., Ferreira, R. T. S., Neto, C. B., Goncalves, J. M. and Mezvial, M. M., 1999, 'An Experimental Analysis of Adiabatic Capillary Tubes,' Applied Thermal Eng., Vol. 19, pp. 669-684
Kim, S. G., Kim, M. S. and Ro, S. T., 2002, 'Experimental Investigation of the Performance of R22, R407C and R410A in Several Capillary Tubes for Air-Conditioners,' Int. J. of Ref., Vol. 25, pp. 521-531
Hong, G. S., 2000, 'An Experimental Study on the Effects of Oil on Refrigerant Flow Through Capillary Tubes,' Ph. D Thesis, Korea Univ., Korea
Ito, H., 1959, 'Friction Factors for Turbulent Flow in Curved Pipes,' Transactions of ASME, Journal of Basic Engineering, Vol. 81, pp. 123-134