This study introduces the design of a bi-directional damper using a tuned mass damper(TMD) and a tuned liquid column damper(TLCD) and presents experimental verifications to confirm its control performance. The damper used in this study behaves as a TMD in a specific translational direction and acts ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Almazan, J. L., Llera, J. C., Inaudi, J. A., Garcia, D. L., Izquierdo, L. E. (2007) A bidirectional and homogeneous tuned mass damper: A new device for passive control of vibrations. Engineering Structures. 29. pp.1548-1560
Den Hartog, J. P. (1956) Mechanical vibrations, McGraw-Hill
Desu, N. B., Deb, S. K., Dutta, A. (2006) Coupled tuned mass dampers for control of coupled vibrations in asymmetric buildings. Struct. Control Health Monit., 13, pp.897-916
Gao, H., Kwok, K. C. S. (1997) Optimization of tuned liquid column dampers, Engineering Structures, 19(6), pp.476-486
Hitchcock, P. A., Kwok, K C. S., Watkins, R. D. (1997a) Characteristics of liquid column vibration absorbers (LCVA)-I, Engineering Structures, 19(2), pp.126-134
Hitchcock, P. A., Kwok, K. C. S., Watkins, R. D. (1997b) Characteristics of liquid column vibration absorbers (LCVA)- II, Engineering Structures, 19(2), pp.135-144
Reiterer, M., Ziegler, F. (2005) Bi-axial seismic activation of civil engineering structures equipped with tuned liquid column dampers, JSEE: Spring, 7(1), pp.45-60
Sakai, F., Takaeda, S., Tamaki, T. (1989) Tuned Liquid Column Damper - New Type Device for Suppression of Building Vibrations, Proc. Int. ConI. on Higbrise Buildings, Nanjing. China, pp.926-931
Shum, K. M. (2008) Closed form optimal solution of a tuned liquid column damper for supressing harmonic vibration of structures, Engineering Structures, doi:10.1016/j.engstruct. 2008.07. 015, in press
Soong, T. T., Dargush, G. F. (1997) Passive Energy Dissipation Systems in Structural Enginnering, John Wiley & Sons
Ueng, J. M., Lin, C. C., Wang, J. F. (2008) Practical design issues of tuned mass dampers for torsionally coupled buildings under earthquake loadings, Struct. Design Tall Spec. Build., 17, pp.133-165
Xu, Y. L., Samali, B., Kwok, K. C. S. (1992) Control of along-wind response of structures by mass and liquid dampers, Journal of Engineering Mechanics, 118(1), pp.20-39
Yalla, S. K., Kareem, A. (2000) Optimum absorber parameters for tuned liquid column dampers, Journal of Structural Engineering, 126(8), pp.906-915
Zhang, X. T., Zhang, R. C., Xu, Y. L. (1993a) Analysis on control of flow-induced vibration by tuned liquid damper with crossed tube-like containers, Journal of Wind Engineering and Industrial Aerodynamics, 50, pp.351-360
Zhang, X. T., Zhang, R. C. (1993b) On control of along-wind and across-wind vibrations of structure by crossed dampers, Proc. Third Asia-Pacific Symp. on Wind Engineering, Hong Kong, 2, pp.859-864
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.