NTIS 바로가기한국정밀공학회지 = Journal of the Korean Society for Precision Engineering, v.26 no.3 = no.216, 2009년, pp.73 - 80
이승우 (한국기계연구원 지능형생산시스템연구본부) , 염한길 (한국기계연구원 에너지플랜트연구본부) , 박길종 ((주)일림나노텍 냉기사업본부)
In accordance with the trend for high-speed multi-axes, and the increasing technical sophistication of machine tools, thermal deformation has become an important factor in the accuracy of machine tools. It was analyzed that thermal deformation error accounts for about 70% of all errors made with mac...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Bryan, J. B., "International Status of Thermal Error Research," Annals of the CIRP, Vol. 39, No. 2, pp. 645-656, 1990
Weck, M., McKeown, P. A., Bonse, R. and Herbst, U., "Reduction and Compensation of Thermal Error in Machine Tools," Annals of the CIRP, Vol. 42, No. 2, pp. 589-598, 1995
Yaqub, M. and Syed, M. Z., "Capacity Control for Refrigeration and Air Conditioning Systems: A Comparative Study," Journal of Energy ResourcesTechnology, Transactions of the ASME, Vol. 123, No. 1, pp. 92-99, 2001
Tso, C. P., Wong, Y. W., Jolly, P. G. and Ng, S. M., "A comparison of hot-gas by-pass and suction modulation method for partial load control in refrigerated shipping containers," International Journal of Refrigeration, Vol. 24, No. 6, pp. 544-553, 2001
Yaqub, M., Syed, M. Z. and Jameel-ur-Rehman, K., "Performance evaluation of hot-gas by-pass capacity control scheme for refrigeration and air-conditioningsystems," Energy, Vol. 25, No. 6, pp. 543-561, 2000
Yaqub, M., Syed, M. Z. and Shamsul, H. K., "Scend- Law-Base Thermodynamic Analysis of Hot-gas, Bypass Capacity Control Schemes for refrigeration and air-conditioning systems," Energy, Vol. 20, No. 6, pp. 483-493, 1995
Byun. J. S., Lee, J. and Jeon, C. D., "Frost retardation of an air-source heat pump by the hot gas bypass method," International Journal of Refrigeration, Vol.31, No. 2, pp. 328-334, 2008
Cho, H., Kim, Y. and Jang, I., "Performance of showcase refrigeration system with multi-evaporator during on-off cycling and hot-gas bypass defrost," Energy, Vol. 30, No. 10, pp. 1915-1940, 2005
Han, X. H., Wang, Q., Zhu, Z. W. and Chen, G. M., "Cycle Performance study on R32/R125/R161 as an alternative refrigerant to R407C," Applied Thermal Engineering, Vol. 27, No. 10, pp. 2559-2565, 2007
Lee, S. W., Yeom, H. K. and Park, K. J., "Assessment Capability of Oil Cooler with Hot Gas," Proc. of KSPE Spring Conference, pp. 455-456, 2007
Statham, A., Martin, A. and Blackshaw, D. M. S., 'Assessing the thermal distortion caused by spindle rotation of a machining center using draft standard ISO/DIS 230-3,' Laser Metrology and Machine Performance III, pp. 101-111, 1997
Lee, S. W., Han, S. W. and Lee, H. S., "Reliability Evaluation of an Oil Cooler for High-Precision Machining Center," International Journal of Precision Engineering and Manufacturing, Vol. 8, No. 3, pp. 50-53, 2007
Ko, T. J., Kim, H. S., Kim, H. S. and Kim, S. H., "Research on the Experiment Methods for the Compensation of Thermal Distortion of Machine Tool Spindle," Proc. of KSPE Autumn Conference, pp. 300-304, 2001