최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기기본간호학회지 = Journal of Korean Academy of Fundamentals of Nursing, v.16 no.2, 2009년, pp.162 - 170
유재희 (가천의과학대학교 간호과학부) , 조현숙 (가천의과학대학교 간호과학부)
Purpose: To verify the usability of tympanic temperature measurement for adults, a comparison of tympanic and axillary temperatures was done. Method: The study was conducted during October 2008, and participants were 110 female nursing students. Axillary temperatures were taken with glass mercury th...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Baird, S. C., White, N. E., & Basinger, M. (1992). Can you rely on tympanic thermometers? RN, 55(8), 48-51.
Choi, M. E, Kim, J. H., Park. M. J. Choi, S. M., & Lee, K. S. (2001). Physiology, Seoul: Hyunmoonsa.
Clemente, C. D. (1985). Gray's anatomy of the human body (30th ed.). Philadelphia: Lea & Febiger.
Devrim, I., Kara, A., Ceyhan, M., Tezer, H., Uludag, A. K., Cengiz, A. B., et al. (2007). Measurement accuracy of fever by tympanic and axillary thermometry. Pediatric Emergency Care, 23(1), 16-19.
Editors of Nursing (2007). Take care with tympanic temperature readings. Nursing, 37(4), 52-53.
Erickson, R. S., & Woo, T. M. (1994). Accuracy of infrared ear thermometry and traditional temperature methods in young children. Heart & Lung, 23(3), 181-195.
Farnell, S., Maxwell, L., Tan, S., Rhodes, A., & Philips, B. (2005). Temperature measurement: Comparison of noninvasive methods used in adult critical care. Journal of Clinical Nursing, 14(5), 632-639.
Fraden, J., & Lackey, R. P. (1991). Estimation of body sites temperatures from tympanic measurements. Clinical Pediatrics, 30(4), 65-70.
Hong, Y. S., & Lee, S. O. (1975). An experimental study on the shortest optimum time for body temperature measurement. Journal of Korean Academy of Nursing, 5(2), 38-50.
Jensen, B. N., Jensen, F. S., Madsen, S. N., & Lessl, K. (2000). Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers. European Journal of Surgery, 166(11), 848-851.
Jeong, I. S., & Yoo, E. J. (1997). Study on the body temperature measuring time and accuracy and reliability of tympanic thermometer. Journal of Korean Academy of Fundamentals of Nursing, 4(1), 19-30.
Kang, H. S., Im, L. Y., Oh, S. Y., Kim, Y. O., Hong, K. P., Kang, J. H., et al. (2006). Fundamentals of nursing I. Seoul: Soomoonsa.
Kim, H. S., & Song, M. G. (1998). Comparison of rectal temperature and tympanic membrane: Temperature in surgical intensive care unit patients. Nursing Science, 10(2), 22-30.
Kim, H. S., & Ahn, Y. M. (1999). Comparison by measurement sites in temperature of neonates: Ear-based rectal, rectal, axilla, abdominal temperature. Journal of Korean Academy of Nursing, 29(4), 903-916.
Kim, J. S. (2001). The comparison of tympanic and axillary temperature measurement for emergency room patients. Unpublished master's thesis, Chonnam National University, Gwangju.
Kocoglu, H., Goksu, S., Isik, M., Akturk, Z., & Bayazit, Y. A. (2002). Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting. International Journal of Pediatric Otorhinolaryngology, 65(1), 39-43.
Koo, H. Y., & Son, J. T. (2005). Comparison of inguinal, rectal, axillary, and tympanic temperature in newborns. Journal of Korean Academy of Child Health Nursing, 11(2), 203-210.
Lee, M. H., Son, J. T., Jang, E. H., Ha, N. S., Park, M. J., Kang, K. S., et al (2003). An introduction to fundamentals of nursing. Seoul: Jungdammedia.
Moran, J. L., Peter, J. V., Solomon, P. J., Grealy, B., Smith, T., Ashforth, W., et al. (2007). Tympanic temperature measurements: Are they reliable in the critically ill? A clinical study of measures of agreement. Critical Care Medicine, 35(1), 155-164.
Nichols, G. A., Ruskin, M. M., Glor, B. A. K., & Kelly, W. H. (1966). Oral, axillary, and rectal temperature determinations and relationships. Nursing Research, 15(4), 307-310.
Onur, O. E., Guneysel, O., Akoglu, H., Aydin, Y. D., & Denizbasi, A. (2008). Oral, axillary, and tympanic temperature measurements in older and younger adults with or without fever. European Journal of Emergency Medicine, 15(6), 334-337.
Pransky, S. M. (1991). The impact of technique and of the tympanic membrane upon infrared thermometry. Clinical Pediatrics, 30(4), 50-52.
Schmitt, B. D. (1991). Behavioral aspects of temperature-taking. Clinical Pediatrics, 30(4), 8-10.
Seo, Y. W. (1992). A comparative study between optimal axillary and rectal body temperatures and optimal thermometer placement time in the full-term normal neonate. Unpublished master's thesis, Yonsei University, Department of Nursing.
Spitzer, O. P. (2008). Comparing tympanic temperatures in both ears to oral temperature in the critically ill adult. Dimensions of Critical Care Nursing, 27(1), 24-29.
Stephen, S. B., & Sexton, P. R. (1987). Neonatal axillary temperatures: Increases in readings over time. Neonatal Network, 5(6), 25-28.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.