최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기설비공학논문집 = Korean journal of air-conditioning and refrigeration engineering, v.21 no.10, 2009년, pp.545 - 552
김성수 (한양대학교 건축공학과) , 손장열 (한양대학교 건축공학과)
It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. And TAB process is applied to control the designed air volume with adjusting volume dampers and/or supply diffusers after fully installing the ventilation system. This p...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Kim, S. S., Son, J. Y., Kim, T. J., Kim, H. J. and Pack, J. S., 2008, Performance Evaluation of Multidrop Chamber Ventilation System in Apartment, Proceeding of the KAIEBS 2008 Autumn Annual Conference, pp. 149-153
Park, Y. W., Park, M. S. and Lee, D. W., 1995, A Numerical Study for Balancing CAV Duct System, Proceeding of Architectural Institute of Korea, Vol. 15, No. 2, pp. 333-336
Lee, D. W., Park, Y. W. and Park, M. S., 1998, Balancing air flow at terminal in CAV duct system with DPM method, SAREK, Vol. 10, No. 1, pp. 66-78
Go, S. H., Lee, H. J. and Park, J. C., 2004, An Experimental study of Ventilation Effectiveness according to Duct Layouts in Apartment Units, SAREK 2008 Winter Annual Conference, pp. 156-159
Song, J. W., Kang, I. K., Kim, S. S., Won, C. H. and Kim, G. O., 2004, Measurements of Flow Resistance in AD to Develope Heat Recovery Ventilator for Highrise Apartment Complex, SAREK 2008 Summer Annual Conference, pp. 362-367
Yang, S. B., Yoon, D. W., Hong, S. M., Kim, J. H., Lee, J. Y. and Lee, S. C., 2008, An Evaluation on the Performance of Air Distributor with Split Guide Vane and its Proper Installation in Residential Ventilation System, Proceeding of the KIAEBS 2008 Autumn Annual Conference
Yee, J. J., Choi, S. Y., Kim, S. K., Kim, K. H., Lee, Y. W. and Kim, H. Y., 2007, A Study on Application of Distributor for Duct Design at House Ventilation System, SAREK, Vol. 19, pp. 770-775
Yoon, D. W. and Yang, S. B., 2009 An, Evaluation on the Performance of Air Distributor with Split Guide Vaneand EVA Flexible Duct in Residential Ventilation System, Journal of Architectural Institute of Korea, Vol. 25, No. 7, pp. 350-312
Choi, J. H., Ju, S. Y. and Yee, J. J., 2007, A Study on Application of Distributor for Duct Design at House Ventilation System, Proceeding of SAREK, pp. 1037-1043
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.