NTIS 바로가기Journal of biomedical engineering research : the official journal of the Korean Society of Medical & Biological Engineering, v.31 no.6, 2010년, pp.449 - 455
한성민 (한국과학기술연구원 의과학연구센터) , 추준욱 (한국과학기술연구원 의과학연구센터) , 전흥재 (연세대학교 기계공학과) , 김정성 ((주)코렌텍) , 최귀원 (한국과학기술연구원 의과학연구센터) , 윤인찬 (한국과학기술연구원 의과학연구센터)
A ceramic articulating system in total hip replacement thought to be superior to metal-on-polyethylene due to its extremely low coefficient of friction and potential for high resistance to wear. But ceramic is brittle, which makes it mechanically and theoretically susceptible to fracture under certa...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Y. S. Park, J. H. Kim, Y. H. Kim, and K. C. Park, "Osteonecrosis of Femoral Head after Pelvic Fracture," J Korean Orthop Assoc, vol. 44, pp. 495-498, 2009.
M. J. Fagan, and A. J. C. Lee, " Material selection in the design of the femoral component of cemented total hip replacements," Clinical Materials, vol. 1, no. 3, pp. 151-167, 1986.
B. Latham, and T. Goswami, "Effect of geometric parameters in the design of hip implants paper IV," Materials & Design, vol. 25, no. 8, pp. 715-722, 2004 .
A. Ramos, and J. A. Simoes, "Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur,", Medical Engineering & Physics, vol. 28, no. 9, pp. 916-924, 2005.
B. Weisse, M. Zahner, W. Weber, and W. Rieger, "Improvement of the reliability of ceramic hip joint implants," Journal of Biomechanics, vol. 36, pp. 1633-1639, 2003.
V.C. Mow, and W. C. Hayes, "Basic Orthopaedic Biomechanics Second Edition," Lippincott-Raven, 1997.
P. Helwig, C. Faust, U. Hindenlang, A. Hirschmuller, L. Konstantinidis, C. Bahrs, N. Sudkamp, and R. Schneider, "Finte element analysis of four different implants inserted in different positions to stabilize an idealized trochanteric femoral fracture," Injury, vol. 40, pp. 288-295, 2008.
J. R. T. Jeffers, M. Browne, A. B. Lennon, P. J. Prendergast, and M. Taylor "Cement mantle fatigue in total hip replacement : Experimental and computational testing," Journal of Biomechanics, vol. 40, pp. 1525-1533, 2007.
H. J. Kim, J. S. Lim, S. M. Han, J. H. You, K. W. Choi, and I. C. Yoon, "Evaluation of mechanical stability in development of customized hip implant," Jouranl of the Korean society of precision engineering, vol. 26, no. 7, pp. 1-2, 2009.
Gudance document for the preparation of premarket notifications of ceramic ball hip systems.
F. Higuchi, N. Shiba, A. Inoue and I. Wakebe, "Fracture of an Alumina Ceramic Head in Total Hip Arthroplasty," The Journal of Arthoplasty, vol. 10, no. 6, 1995.
S. Y. Kim, Y. G. Kim, J. Y. Yeo, D. H. Kim, and J. C. Ihn "Ceramic-on-Ceramic Bearing Total Hip Athroplasty in Young Patients with Osteonecrosis of Femoral Head," J.of Korean Orthop. Assoc. vol. 39, pp. 233-8, 2004.
A, Arenas, A. Tejero, A. Garbayo, C. Arias, J. Barbadillo, and J. Lecumberri "Ceramic femoral heal fractures I total hip replacement," International Orthopaedics, vol. 23, pp. 351-352, 1999.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.