최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기韓國地盤工學會論文集 = Journal of the Korean geotechnical society, v.27 no.11, 2011년, pp.93 - 101
정연종 (연세대학교 사회환경시스템공학부) , 윤태섭 (연세대학교 사회환경시스템공학부) , 김광염 (한국건설기술연구원) , 주진현 (한국건설기술연구원)
High quality X-ray computed microtomography (micro-CT) imaging of internal microstructures and pore space in geomaterials is often hampered by some inherent noises embedded in the images. In this paper, we introduce image calibration techniques for removing the most common noises in X-ray micro-CT, ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Adler, P.M., (1992), Porous Media: Geometry and Transport. Butterworth-Heinemann Series of Chemical Engineering. Stoneham, Massachusetts: Butterworth-Heinemann.
Bernard, D. and Chirazi, A., Numerically enhanced microtomographic imaging method using a novel ring artifact filter, in Advances in X-ray tomography for geomaterials, J. Desrues, G. Viggini, and P. Besuelle, Editors. 2006.
Boin, M. and Haibel, A., (2006), "Compensation of ring artefacts in synchroton tomographic images", Optics Express, 14(25), pp.12071-12075.
Chen, Y.-W. and Duan, G., (2009), "Independent component analysis based rign artifact reduction in cone-beam CT images", International conference on image processing. Cairo, Egypt. pp.4189-4192.
Choi, J.-H., Seol, Y., Boswell, R., and Juanes, R., (2011), "X-ray computed-tomography imaging of gas migration in water-saturated sediments: From capillary invasion to conduit opening", Geophys. Res. Lett., 38(17), pp.Ll7310.
Davis, G. R. and Elliott, J. c., (1997), "X-ray microtomography scanner using time-delay integration for elimination of ring artifat in the reconstructed image", Nuclear instruments and Methods in Physics Research A, 394 pp.157-162.
Hall, S. A., Bornert, M., Desrues, J., Pannier, Y., Lenoir, N., Viggiani, G., and BeSulle, P., (2010), "Discrete and continuum analysis of localised deformation in sand using X-ray -CT and volumetric digital image correlation", Geotechnique, 60(5), pp.315-322.
Hiriyannaiah, H. P., (1997), "X-ray computed tomography for medical imaging", Signal Processing Magazine, IEEE, 14(2), pp.42-59.
Keehm, Y., Sternjof, K., and Mukerji, T., (2006), "Computational estimation of compaction band permeability in sandstone", Geosciences Journal, 10(4), pp.499-505.
Lenoir, N., Bornert, M., Desrues, J., Besuelle, P., and Viggiani, G., (2007), "Volumetric Digital Image Correlation Applied to X-ray Microtomography Images from Triaxial Compression Tests on Argillaceous Rock", Strain, 43(3), pp.193-205 .
Narsilio, G. A., Buzzi, 0., Fityus, S., Yun, T. S., and Smith, D. W., (2009), "Upscaling of Navier-Stokes equations in porous media: Theoretical, numerical and experimental approach", Computers and Geotechnics, 36(7), pp.1200-1206.
Otsu, N., (1979), "A threshold selection method from gray-level histogram", lEE Transactions on Systems, Man, and Cybernetics, 9, pp.62-66.
Prell, D., Kyriakou, Y., and Kalender, W. A., (2009), "Comparison of ring artifact correction methods for flat-detector CT", Physics in Medicine and Biology, 54, pp.3881-3895 .
Raven, c., (1998), "Numerical removal of ring artifacts in microtomography", Review of Scientific Instruments, 69(8), pp.2978-2980.
Seibert, J. A., Boone, J. M., and Kindfors, K. K., (1998), Flat-field correction technique for digital detectors, in SPIE Conference on Physics of Medical Imaging, San Diego, CA, USA, p.348-354.
Sun, W., Andrade, J. E., Rudnicki, J. W., and Eichhubl, P., (2011), "Connecting microstructural attributes and permeability from 3D tomographic images of in situ shear-enhanced compaction bands using rrrultiscale computations", Geophys. Res. Lett., 38(10), pp.Ll0302.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.