NTIS 바로가기Journal of power electronics, v.11 no.3, 2011년, pp.369 - 374
Choi, Hyeong-Jin (Dept. of Electrical Engineering, Kwangwoon University) , Song, Seung-Ho (Dept. of Electrical Engineering, Kwangwoon University) , Jeong, Seung-Gi (Dept. of Electrical Engineering, Kwangwoon University) , Choi, Ju-Yeop (Dept. of Electrical Engineering, Kwangwoon University) , Choy, Ick (Dept. of Information Control Engineering, Kwangwoon University)
Usually, a LPF (low pass filter) is used in the feedback loop of a SRF (synchronous reference frame) - PLL (phase locked loop) system because the measured grid voltage contains harmonic distortions and sensor noises. In this paper, it is shown that the cut-off frequency of the LPF should be designed...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
S.-J. Lee and S.-K. Sul, "A new phase detecting method for power conversion systems considering distorted conditions in power system," IEEE Industry Applications Conference, Vol. 4, pp. 2167-2172, Oct. 1999.
P. Rodriguez, A. Luna, R. Teodorescu, F. Iov, and F. Blaabjerg, "Fault ride-through capability implementation in wind turbine converters using a decoupled double synchronous reference frame PLL" Power Electronics and Applications, 2007 European Conference, pp. 1-10, Sep. 2007.
P. Rodriguez, J. Pou, J. Bergas, J. I. Candela, R. P. Burgos, and D. Boroyevich, "Decoupled double synchronous reference frame PLL for power converters control," IEEE Trans. Power Electron., Vol. 22, No. 2, pp. 584-592, Mar. 2007.
S.-K. Chung, "Phase-locked loop for grid- connected three-phase power conversion system," in Proc. IEE Electric Power Applications, Vol. 147, No. 3, pp. 213-219, May 2000.
S.-K. Chung, "A phase tracking system for three phase utility interface inverters," IEEE Trans. Power Electron., Vol. 15, No. 3, pp. 431-438, May 2000.
M. Kamata, T. Shono, T. Saba, I. Sasase, and S. Mori, "Third-order phase-locked loops using dual loops with improved stability," IEEE Pacific Rim Conference, Vol. 1, pp. 20-22, Aug. 1997.
J. K. Kang and S. K. Sul, "Control of unbalanced voltage PWM converter using instantaneous, ripple power feedback," in Proc. IEEE-PESC Ann.Meet., pp.503-508, 1997.
A. V. Timbus, R. Teodorescu, F. Blaabjerg, M. Liserre, and P. Rodriguez, "PLL algorithm for power generation systems robust to grid voltage faults," Power Electronics Specialists Conference, pp. 1-7, Jun. 2006.
S. Song, S. Kang, and N. Hahm, "Implementation and control of grid connected AC-DC-AC power converter for variable speed wind energy conversion system," in Proc. 2003 IEEE Applied Power Electronics Conference and Exposition, Vol. 1, pp.154-158, 2003.
H.-J Choi, S.-H Song, S.-G Jeong, and J.-Y Choi, "High speed monitoring of grid voltage phase and magnitude for LVRT," Korea Wind Energy Association Conference, pp. 109-112, Oct. 2008.
H.-J Choi, S.-H Song, S.-G Jeong, J.-Y Choi, and I. Choy, "Enhanced dynamic response of SRF-PLL system in a 3 phase grid-connected inverter," Transactions of Korea Institute of Power Electronics, Vol. 14, No. 2, pp. 134-141, Apr. 2009.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
저자가 APC(Article Processing Charge)를 지불한 논문에 한하여 자유로운 이용이 가능한, hybrid 저널에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.