NTIS 바로가기한국전산구조공학회논문집 = Journal of the computational structural engineering institute of Korea, v.28 no.6, 2015년, pp.607 - 614
In this research, the structural analysis and safety evaluation for Sungnyemun -No.1 national treasure of Korea- was performed. Roof loads were calculated in detail, and structural analysis model was constructed using Midas Gen ver.820. Static structural analysis under vertical loads was performed a...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Fang, D.P., Iwasaki, S., Yu, M.H., Shen, Q.P., Miyamoto, Y., Hikosaka, H. (2001a) Ancient Chinese Timber Architecture I: Experimental Study, J. Struct. Eng., 127(11), pp.1348-1357.
Fang, D.P., Iwasaki, S., Yu, M.H., Shen, Q.P., Miyamoto, Y., Hikosaka, H. (2001b) Ancient Chinese Timber Architecture II: Dynamic Characteristics, J. Struct. Eng., 127(11), pp.1358-1364.
Han, J.S., Kim, C.J. (2005) An Experimental Study on Mechanical Performance of Tenon for Analysis of Structural System and Modernization of Traditional Wooden Architecture, J. Archi. Inst. Korea : Struct. & Constr., 21(4), pp.121-128.
Hwang, J.G., Hong, S.G., Lee, Y.W., Jung, S.J. (2009) Natural Frequency Characteristics of Traditional Wooden Structure for Vibration Amplitude, J. Archi. Inst. Korea : Struct. & Constr., 25(5), pp.3-10.
Kang, M., Yang, N., Cha, Q. (2011) Studies on Static Performance of Mortise and Tenon Joint in Traditional Column and Tie Construction Timber Structure, Electric Technology and Civil Engineering (ICETCE) 2011 International Conference, pp.6197-6200.
Kim, Y.M. (2014a) Dynamic Experiments on a 1-4 Scale New-styled Korean Traditional Wooden House. Appl. Mech. & Mater., 598, pp.743-746.
Kim, Y.M. (2014b) Monitoring of Moisture Contents in Korean Traditional Wooden Houses. In Proceedings of the World Congress on Engineering 2014, pp.1298-1303.
Lee, Y.W., Bae, B.S., Hong, S.G., Hwang, J.G., Kim, N.H., Jung, S.J. (2006) An Analytical Modelling of the Beam-Direction Frame of Traditional Wood Structure System, J. Archi. Inst. Korea : Struct. & Constr., 22(3), pp.29-36.
Lee, Y.W., Hong, S.G., Hwang, J.G., Bae, B.S. (2007) Capacity of Lateral Load Resistance of Dori-Directional Frame with Jangbu-connection in Traditional Wood Structure System, J. Archi. Inst. Korea : Struct. & Constr., 23(2), pp.35-42.
Lindt, J.W., Pei, S., Pryor, S.E., Shimizu, H., Isoda, H. (2010) Experimental Seismic Response of a Full-scale Six-Story Light-Frame Wood Building, J. Struct. Eng., 136(10), pp.1262-1272.
Min, K.W., Park, S.A. (2011) Simple Structural Model and Seismic Analysis of Heunginjimum, J. Archi. Inst. Korea : Struct. & Constr., 27(4), pp.23-30.
Seo, J.M., Choi, I.K., Lee, J.R. (1999) Static and Cyclic behavior of Wooden Frames with Tenon Joints under Lateral Load, J. Struct. Eng., 125(3), pp.344-349.