NTIS 바로가기Journal of electrical engineering & technology, v.10 no.2, 2015년, pp.603 - 609
Min, Gyeong-Jun (Dept. of Electrical Engineering, Yeungnam University) , Bae, Sungwoo (Dept. of Electrical Engineering, Yeungnam University) , Kang, Byoung-Chil (Dept. of Electrical Engineering, Yeungnam University) , Park, Won-Zoo (Dept. of Electrical Engineering, Yeungnam University)
Dry air is an excellent alternative to
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
L. G. Christophorou, J. K. Olthoff and R. J. Van Brunt, “Sulfur hexafluoride and the electric power industry,” IEEE Electr. Insul. Mag., vol. 13, no. 5, pp. 20-24, Sept.-Oct. 1997.
T. Rokunohe, Y. Yagihashi, K. Aoyagi, T. Oomori and F. Endo, “Development of SF 6 -Free 72.5 kV GIS,” IEEE Trans. Power Deliv., vol. 22, no. 3, pp. 1869-1876, Jul. 2007.
T. Yoshida, H. Koga, T. Harada, S. Miki, M. Arioka, S. Sato, S. Yoshida, N. Inoue, A. Maruyama and T. Takeuchi, “Insulation technology in dry air and vacuum for a 72kV low pressure dry air insulated switchgear,” Electr. Eng. Japan, vol. 175, no. 1, pp. 18-24, Apr. 2011.
H. Park, E. Choi, L. Kim and K. Lee, “Surface Discharge Characteristics for Epoxy Resin in Dry-Air with variations of Electrode Features and Epoxy Resin Size,” J. Korean Inst. Illumi. Electr. Installa. Eng., vol. 23, no.2, pp. 154-160, Feb. 2009.
CIGRE WG 15.03: “Long-term performance of SF6 insulated systems,” CIGRE Report 15-301, 2002.
H. C. Miller, “Surface flashover of insulators,” IEEE Trans. Electr. Insul., vol. 24, no. 5, pp. 765-786, Oct. 1989.
T. Takuma and B. Techaumnat, Electric Fields in Composite Dielectrics and their Applications, New York: Springer, 2010.
K. Kato, M. Kurimoto, H. Shumiya, H. Adachi, S. Sakuma and H. Okubo, “Application of functionally graded material for solid insulator in gaseous insulation system,” IEEE Trans. Dielectr. Electr. Insul., vol. 13, no. 1, pp. 362-372, Dec. 2006.
M. Kurimoto, K. Kato, M. Hanai, Y. Hoshina, M. Takei and H. Okubo, “Application of functionally graded material for reducing electric field on electrode and spacer interface,” IEEE Trans. Dielectr. Electr. Insul., vol. 17, no. 1, pp. 256-263, Feb. 2010.
L. Shengtao, Z. Tuo, H. Qifeng, L. Weiwei, N. Fengyan and L. Jianying, “Improvement of Surface Flashover Performance of Al 2 O 3 Ceramics in Vacuum by Adopting A-B-A Insulation System,” Plasma Sci. and Tech., vol. 13, no. 1, pp. 235-241, Jan. 2011.
G. Min, B. Kang, D. Lim, K. Lee and W. Park, “A Study of Surface Discharge Characteristics for Dew- Point of Dry-Air and Materials or Shapes of Solid Insulator in Quasi-Uniform Field,” J. Korean Inst. Illumi. Electr. Installa. Eng., vol. 27, no. 6, pp. 44-49, Jun. 2013.
J. R. Laghari, “Spacer Flashover in Compressed Gases,” IEEE Trans. Electr. Insul., vol. EI-20, no. 1, pp. 83-92, Feb. 1985.
G. Min, B. Kang, S. Bae, K. Lee and W. Park, “Study of surface discharge characteristics for laminated solid insulator in quasi-uniform field of dry air,” in Proc. 2013 KIIEE Spring, Annu. Conf., pp. 27-28.
D. Lim, G. Min, H. Park, E. Choi, S. Choi, S. Bae, S. Rhee, W. Park, K. Lee, “Analysis of Medium Effect by gas Pressure and Gap at Surface Discharge of Dry Air,” J. Korean Inst. Illumi. Electr. Installa. Eng., vol. 27, no. 10, pp. 86-92, Oct. 2013.
H. Park, “Surface Discharge of Solid Dielectrics in Different Media,” M. S. thesis, Yeungnam University, Gyeongsan-si, Gyeongsangbuk-do, Korea, 2008.