NTIS 바로가기大韓建築學會論文集. Journal of the architectural institute of korea. 構造系, v.32 no.11 = no.337, 2016년, pp.3 - 9
노지은 (단국대학교 건축공학과) , 이상현 (단국대학교 건축공학과)
In this study, a multi-action hybrid damper (MHD) showing independent hysteretic characteristics for small and large loading conditions is presented. The MHD is composed of steel elements, two friction pads, and two lead-rubber bearings. Since the friction pads and the lead-rubber bearings are in se...
Bergman, D. & Goel S. (1987). Evaluation of cyclic testing of steel plate devices for added damping and stiffness. Report No. UMCE87-10, University of Michigan, 37.
Tsai, K., Chen, H., Hong, C. & Su, Y. (1993). Design of steel triangular plate energy absorbers for seismic-resistant construction. Earthquake Spectra, 9(3), 505-528.
Kobori, T., Miura, Y., Fukusawa, E., Yamada, T., Arita, T. & Takenake, Y. (1992). Development and application of hysteresis steel dampers. In Proceedings of 11th world conference on earthquake engineering, 2341-2346.
Clark, P., Aiken, I., Tajirian, F., Kasai, K., Ko, E. & Kimura, I. (1999). Design procedures for buildings incorporating hysteretic damping devices. Passive energy dissipation and active control of vibrations of structures, 1-21.
Pall, A. & Marsh, C. (1982). Response of friction damped braced frames. Journal of Structural Division, ASCE. 108(6), 1313-1323.
Mualla, I. (2000). Experimental and computational evaluation of a novel friction damper device, PhD thesis, Technical University of Denmark.
Fitzgerald, T., Anagnos, T., Goodson, M. & Zsutty, T. (1989). Slotted Bolted Connections in Aseismic Design for Concentrically Braced Connections. Earthquake Spectra. 5(2), 383-391.
Robinson, W. (1982). Lead rubber hysteretic bearings suitable for protecting structures during earthquakes. Earthquake Engineering & Structural Dynamics. 10(4), 593-604.
Filiatrault, A. & Cherry, S. (1990). Seismic design spectra for friction-damped structures. Journal of Structural Engineering. 116, 334-355.
Fu, Y. & Cherry, S. (2000). Design of friction damped structures using lateral force procedure. Earthquake engineering & structural dynamics. 29(7), 989-1010.
Lee, S., Park, J., Lee, S. & Min, K. (2008). Allocation and slip load of friction dampers for a seismically excited building structure based on storey shear force distribution, Engineering Structures. 30(4), 930-940.
Wu, J., Yang, J. & Schmitendorf, W. (1998). Reduced-order H ${\infty}$ and LQR control for wind-excited tall buildings, Engineering Structures. 20(3), 222-236.
Korean Architectural Institute. (2009). KBC 2009.
Kim, D., Kim, J., Kim, D., Ha, I., Ahn, T., Kim, H. & Kim, S. (2010). Experimental study on hybrid damper using a high-damping rubber and a steel pin. 2010 Conference Journal of Architectural Institute of Korea. 30(1), 9-10.