최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기大韓建築學會論文集. Journal of the architectural institute of korea. 構造系, v.33 no.8 = no.346, 2017년, pp.11 - 19
임종진 (단국대 건축구조 대학원) , 김동관 (청주대 건축공학과) , 이상현 (단국대 건축공학과) , 엄태성 (단국대 건축공학과)
In the present study, exterior composite beam-to-column connections using thin steel plates were tested under cyclic loading. Octagonal steel tubes and U-section steel beams with a thickness of 6 mm were used for the composite column and beam, respectively. To transfer the tension force of beam flan...
duPlessis, D. P., & Daniels, J. H. (1973). Strength of composite beam-to-column connections, Fritz Laboratory Reports. Paper 2035.
Tagawa, Y., Kato, B., & Aoki, H. (1989). Behavior of Composite Beams in Steel Frame Under Hysteretic Loading, Journal of Structural Division, ASCE, 115(8), 2029-2045.
Lee, S. J. (1987). Seismic Behavior of Steel Building Structures with Composite Slabs, ph. D. Dissertation, Department of Civil Engineering, Lehigh University, Bethlehem.
Alostaz, Y.M., & Schneider, S.P. (1996). Connections to concrete-filled steel tubes, A report on research sponsored by the National Science Foundation, University of Illinois at Urbana-Champaign, Illinois.
Lee, S. h., Jung, H. M., Kim, D. J., Kim, J. H., & Choi. S. M. (2008). Structural Characteristic of Welded Built-up Square CFT Column to Beam Connections with External Diaphragm, Journal of Korean Society of Steel Construction, KSSC, 11(1), 711-723.
Park, J. H., Kang, S. M., & Kim, U. J. (2003). Seismic Performance of Weld Flange Beam-to-Concrete Filled Tube Column Joints with Stiffening Plates around the Column, Journal of Korean Society of Steel Construction, KSSC, 15(2), 167-175.
Shin, K. J., Kim, Y. J., Oh Y. S., & Moon, T. S. (2004). Behavior of welded CFT column to H-beam connections with external stiffeners, Journal of Engineering Structures, 26(13) 1877-1887
Chen, C.-C., Lin, C.-C., & Tsai, C.-L. (2004). Evaluation of reinforced between steel beams and box columns, Journal of Engineering Structures, 26, 1889-1904.
Shanmugan, N.E., Ting, L.C., & Lee, S.L. (1991). Behavior of I-beam to box-column connections stiffened externally and subjected to fluctuating loads, Journal of Constructional Steel Research, 20(2), 129-148.
Beutel, J., Thambiratnam, D., & Perera, N. (2002). Cyclic behavior of concrete filled steel tubular column to steel beam connections, Journal of Engineering Structures, 24(1), 29-38.
Azizinamini, A. & Prakash, B. (1993). A tentative Design Guidelines for a New Steel Beam Connection Detail to Composite Tube Columns, AISC Engineering Journal, 3rd quarter, 108-115.
Morino, S., & Tsuda, K. (2003). Design and construction of concrete-filled steel tube column system in Japan, Earthquake Engineering and Engineering Seismology, 4(1), 51-73.
Wu, L.Y., Chung, L.L., & Tsai, S. F. (2005). Seismic behavior of bolted beam-to-column connections for concrete filled steel tube, Journal of Constructional Steel Research, 61(10), 1387-1410.
Mirghaderi, S.R., Torabian, S., & Keshavarzi, F. (2010). I-beam to box-column connection by a vertical plate passing through the column, Journal of Engineering Structures, 32(8), 2034-2048.
America Institute of Steel Construction (2010). Specification for Structural Steel Buildings, ANSI/AISC 360-10, Chicago, IL.
America Institute of Steel Construction (2010). Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications, ANSI/AISC 358-10, Chicago, IL, 2010.
The Europen Standard (2004). Eurocode 8, Design of structures for earthquake resistance, BS EN 1988-1.
Korea Concrete Institute (2012). Design Code for Concrete Structures.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.