최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기大韓建築學會論文集. Journal of the architectural institute of korea. 構造系, v.33 no.11 = no.349, 2017년, pp.35 - 42
이수환 (서울대 대학원) , 이병희 (서울대 대학원) , 백지민 (서울대 대학원) , 강동화 (서울시립대 건축학과) , 여명석 (서울대 건축학과) , 김광우 (서울대 건축학과)
Airtightness of modern buildings has been increased and people are staying indoors about 20 hours a day. As indoor residence time increase, effect of indoor air quality on health got higher. Deposition rate and penetration factor are important factors for predicting indoor particle concentration. Ho...
Alzona, J., Cohen, L., Rudolph, H., Jow, N., & Frohliger, O. (1979). Indoor-.outdoor relationships for airborne particle matter of outdoor origin, Atmospheric Environment, 13, 55-60.
Chao, C., Wan, P., & Cheng ,E. (2003). Penetration coefficient and deposition rate as a function of particle size in non-smoking naturally ventilated residences, Atmospheric Environment, 37, 4233-4241.
Chen, C., & Zhao, B. (2011). Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor, Atmospheric Environment, 45, 275-288.
He, C., Morawska, L., & Gilbert, D. (2005). Particle deposition rates in residential houses, Atmospheric Environment, 39, 3891-3899.
Fogh, C., Byrne, M., Roed, J., & Goddard, A. (1997). Size specific indoor aerosol deposition measurements and derived I/O concentration ratios, Atmospheric Environment, 31, 2193-2203.
Sehmel, G. (1980). Particle and gas dry deposition: A review, Atmospheric Environment, 14, 983-1011.
Long, C., Suh, H., Catalano, P., & Koutrakis, P. (2001). Using time- and size-resolved particulate data to quantify indoor penetration and deposition behavior, Environmental Science and Technology, 35, 2089-2099.
Mosley, R., Greenwell, D., Sparks, L., Guo, Z., Tucker, W., Fortmann, R., & Whitfield, C. (2001). Penetration of ambient fine particles into the indoor environment. Aerosol Science and Technology, 34, 127-136.
Ministry of Environment(2014), Interior Fine Dust Management manual, Korea.
Ministry of Environment(2003), Comprehensive Measures to Prevent Dust Damage, Korea.
National Institute of Environmental Research(2010), Research on Residential Indoor Air Quality Management Plan(2), Korea.
Thatcher, T., Lai, A., Jachson, R., Sextro, R., & Nazaroff, W. (2002). Effect of room furnishings and air speed on particle deposition rates indoors, Atmospheric Environment, 36, 1811-1819.
Vette, A., Rea, A., Lawless, P., Rodes, C., Evans, G., Highsmith, V., & Sheldon, L. (2001). Characterization of indoor-outdoor aerosol concentration relationships during the Fresno PM exposure studies, Aerosol Science and Technology, 34, 118-126.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.