최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국건축시공학회지 = Journal of the Korea Institute of Building Construction, v.18 no.6, 2018년, pp.527 - 532
박종범 (Department of Architectural Engineering Graduate School, Kyonggi University) , 윤현섭 (Department of Architectural Engineering Graduate School, Kyonggi University) , 양근혁 (Department of Architectural Engineering, Kyonggi University)
The objective of the present study is to evaluate a practical approach for enhancing the compressive strength and minimizing deforming of aerated concrete. Test results measured in the aerated concrete mixes that were produced using 40% ground granulated blast-furnace slag (GGBS) as a replacement of...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
핵심어 | 질문 | 논문에서 추출한 답변 |
---|---|---|
선 기포방식의 습식형 기포 콘크리트는 어떻게 제작하는가? | 경량 기포 콘크리트는 기포의 도입방법에 따라 크게 선기포 방식의 습식형 기포 콘크리트와 후 기포 방식의 고온고압 기포 콘크리트(autoclaved aerated concrete, AAC)로 구분된다[1]. 선 기포방식의 습식형 기포 콘크리트는 시멘트계 재료에 기반한 페이스트와 기포 발생기를 통해 미리 생성된 기포군을 혼합해 제작한다. 경량 기포 콘크리트는 매트릭스 내의 수많은 공극으로 밀도가 보통 콘크리트의 약 1/4이하 수준이며, 이와 같은 특성으로 높은 단열성능을 가진다 [2]. | |
소포현상이 발생하게 되는 원인이 되는것은? | 기포콘크리트 내에 존재하는 기포량이 적을 때 개개의 기포는 응집력이 작아 간섭하지 않지만 기포량이 증가 하게 되면 기포간의 응집력이 증가한다[5]. 이에 따라 기포간 이격거리가 감소하면 기포막의 병합 및 중첩이 발생하게 되며 이는 소포로 이어질 수 있다. 기포 콘크리트에서 소포 현상을 방지하기 위한 대책으로 단위 시멘트양을 높이거나 물-결합재비(water to binder ratio, W/B)를 낮추어 기포의 양을 상대적으로 감소시켜 기포간의 간섭을 최소화하는 방법이 있다[6]. | |
경량 기포 콘크리트의 구분방법은? | 경량 기포 콘크리트는 기포의 도입방법에 따라 크게 선기포 방식의 습식형 기포 콘크리트와 후 기포 방식의 고온고압 기포 콘크리트(autoclaved aerated concrete, AAC)로 구분된다[1]. 선 기포방식의 습식형 기포 콘크리트는 시멘트계 재료에 기반한 페이스트와 기포 발생기를 통해 미리 생성된 기포군을 혼합해 제작한다. |
Lee CH, Eo SH. An experimental study on the physical properties of lightweight foamed concrete according to the mix proportions. Journal of the Construction and environment research institute. 2014 Dec;9(2):52-63.
Kim DH, Choi DH. An experimental study on the characteristics of lightweight foamed concrete used as the refractory filler. Journal of the Korean Society of Hazard Mitigation. 2012 Dec;12(6):231-7.
Lee KH, Yang KH. Effect of fiber addition for improving the properties of lightweight foamed concrete. Journal of the Korea Institute of Building Construction. 2015 Aug;15(4):383-9.
Han SY, Han MC. Properties and mock-up test of lightweight foamed concrete based on blast furnace slag by crack reducing admixture. Journal of the Korea Institute of Building Construction. 2017 Dec;17(6):507-15.
Lee SH, Yong WJ, Park JJ. A study on the sound absorption properties of cellular concrete with continuous voids. Journal of the Korea Concrete Institute. 2003 Aug;15(4):566-73.
Lee SH. Effect of foaming agent on the continuous void in lightweight cellular concrete. Journal of the Korea Concrete Institute. 2002 Oct;14(5):742-9.
Yang WH. An experimental study on the properties of foamed concrete within blast-furnace slag [master's thesis]. [Seoul (Korea)]: Konkuk University; 2001. 58 p.
Kim SW. Park WS, Jang YI, Yun SH, Yun HD, Kim DG. Effect of curing temperature on the strength development of concrete containing blast-furnace slag and silica fume. Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology. 2014 Dec;4(2):271-80.
Oh SC, Seo CH, Kim DH. An experimental study on the physical properties of foamed concrete with blast-furnace slage. Journal of the Architectural Institute of Korea Structure & Construction. 2002 Jul;18(7):59-67.
Lee KH. Development of ixture proportioning model for low-density high-strength foamed concrete [master's thesis]. [Suwon (Korea)]: Kyonggi University; 2013. 103 p.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.