This study evaluated the fire resisting capacity and post-fire serviceability of the concrete beams retrofitted by near surface mounted method(NSM) using GFRP plates. Main parameters in the test are grout materials and fire exposure. For the test, two types of grout materials between concrete substr...
Meier, U., & Winistorfer, A. (1995). Retrofitting of structures through external bonding of CFRP sheets, Proceedings of the Second International RILEM Symposium, 509-516
Foster, S., & Bisby, L. (2008). Fire survivability of externally bonded FRP Strengthening Systems, Journal of Composites for Construction, 12(5), 553-561.
Seo, S., Oh, J., & Choi, K. (2011). Bond capacity of concrete member strengthened by various methods using FRP plate, Journal of the architectural institute of Korea structure & construction, 27(8), 55-63.
El-Hacha, R., & Rizkalla, S. (2004). Near surface mounted FRP reinforcements for flexural strengthening of concrete Structures, ACI Structural Journal, 101(5), 717-726.
Jung, W. (2009). Flexural behavior of reinforced concrete beams strengthened with NSM CFRP reinforcements considering the equivalent section, Thesis, Myongji University, 217-219.
Korean Industrial Standards(2004), KS M 3381: Testing method for tensile properties of glass fiber reinforced plastics, 1-11
Jung, S. (2010). Flexural strength of RC beams strengthened with GFRP using cementitious filler, Thesis, Soongsil University, 35.
Soliman, E., Kandil, U., & Taha, M. (2015). Investigation of FRP lap spliced using epoxy constaining carbon nanotubes, Journal of Composities for Construction, 19(2), 2015
Korean Industrial Standards(2002), KS M ISO 527-4: Plastics - Determination of tensile properties - Part 4: Test conditions for isotropic and orthotropic fibre-reinforced plastic composites, 1-13
Korean Industrial Standards(2014), KS F 2257-1: Methods of fire resistance test for elements of building construction-general requirements, 1-30
Oh, J., Ju, M., Seo, S., Kim, S., Lim, K., & Park, C. (2014). Fire safety analysis of the concrete bridge structure with standard fire curve and real scale fire curve, Proceedings of the Korea Concrete Institute, 26(1), 69-70
Korean Industrial Standards(2014), KS F 2257-6: Methods of fire resistance test for elements of building construction-specific requirements forements for beams, 1-20
Kim, D., Han, B., Lee, J., Harada, K., & Kwon, Y. (2011). The influence of compressive strength and moisture contents on explosive spalling of concrete, Fire Science and engineering, 25(1), 42-49
Saito, H. (1966). Explosive spalling of prestressed concrete in fire, Bull. of The Fire Prevention Society of Japan, 15(2), 23-30
Choi, Y., Chae, I., Kang, Y., Won, J., Kim, J., & Kim, S. (2011). Tuning thermal expansion coefficient of composites containing epoxy resin/inorganic additives for stone consercation, Journal of conservation science, 27(4), 431-440
British Standards Institution(1985), BS8110: Structural use of concrete, 1-10
Seo, S., Choi, K., & Kwo, Y. (2012). Retrofit capacity of near-surface-mounted RC beam by using FRP plate, Journal of the Korea institute for structural maintenance and inspection, 16(1), 18-26
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.