최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Current optics and photonics, v.3 no.2, 2019년, pp.177 - 180
Kong, Meimei (School of Electronic and Optical Engineering & School of Microelectronics, Nanjing University of Posts and Telecommunications) , Chen, Xin (School of Electronic and Optical Engineering & School of Microelectronics, Nanjing University of Posts and Telecommunications) , Yuan, Yang (School of Electronic and Optical Engineering & School of Microelectronics, Nanjing University of Posts and Telecommunications) , Zhao, Rui (School of Electronic and Optical Engineering & School of Microelectronics, Nanjing University of Posts and Telecommunications) , Chen, Tao (School of Electronic and Optical Engineering & School of Microelectronics, Nanjing University of Posts and Telecommunications) , Liang, Zhongcheng (School of Electronic and Optical Engineering & School of Microelectronics, Nanjing University of Posts and Telecommunications)
Based on liquid-lens technology and our previous findings on the optical model of the Chinese eye, the liquid lens is applied in the research of the crystalline-lens optical model. Theoretical models of three-layer liquid lenses are built with COMSOL software, and the effect of voltage on the shape ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
D. Ke and X. Cheng, "Current trends of liquid lenses," in Proc. International Photonics and OptoElectronics Meetings, OSA Technical Digest (online) (Optical Society of America, 2014), paper OF3A.3.
G. Gratton, J. S. Maier, M. Fabiani, W. W. Mantulin, and E. Gratton, "Feasibility of intracranial near-infrared optical scanning," Psychophysiology 31, 211-215 (1994).
H. Ren and S. Wu, "Variable-focus liquid lens by changing aperture", Appl. Phys. Lett. 86, 1679-1681 (2005).
L. Li, C. Liu, H. Ren, H. Deng, and Q. Wang, "Annular folded electrowetting liquid lens," Opt. Lett. 40, 1968-1971 (2015).
B. Berge, "Liquid lens technology: principle of electrowetting based lenses and applications to imaging", in Proc. 18th IEEE International Conference on Micro Electro Mechanical Systems (USA, Jan. 2005), pp. 227-230.
S. Kuiper and B. H. W. Hendriks, "Variable-focus liquid lens for miniature cameras", Appl. Phys. Lett. 85, 1128-1130 (2004).
M. Kong, D. Chen, X. Chen, Z. Liang, R. Zhao, and E. Xu, "Research of the human eye model with variable-focus liquid lens," Microfluid. Nanofluid. 21, 40 (2017).
W. Qiao, F. S. Tsai, S. H. Cho, H. Yan, and Y.-H. Lo, "Fluidic intraocular lens with a large accommodation range", IEEE Photon. Technol. Lett. 21, 304-306 (2009).
Z. Ding, C. Wang, Z. Hu, Z. Cao, Z. Zhou, and X. Chen, "Surface profiling of an aspherical liquid lens with a varied thickness membrane," Opt. Express 25, 3122-3132 (2017).
C. N. Wilson, A fully customizable anatomically correct model of the crystalline lens (2011).
M. Kong, Z. Gao, X. Li, S. Ding, X. Qu, and M. Yu, "A generic eye model by reverse building based on Chinese population", Opt. Express 17, 13283-13297 (2009).
M. Kong and Z. Li, "Research of bright pupil effect based on Chinese human eye model", Chin. Opt. Lett. 12, 113301-1-113301-3 (2014).
H. Liou and N. Brennan, "Anatomically accurate, finite model eye for optical modeling", J. Opt. Soc. Am. A 14, 1684-1695 (1997).
I. Escudero-Sanz and R. Navarro, "Off-axis aberrations of a wide-angle schematic eye model", J. Opt. Soc. Am. A 16, 1881-1891 (1999).
P. Artal and R. Navarro, "Monochromatic modulation transfer function of the human eye for different pupil diameters: an analytical expression," J. Opt. Soc. Am. A 11, 246-249 (1994).
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.