NTIS 바로가기Nuclear engineering and technology : an international journal of the Korean Nuclear Society, v.51 no.2, 2019년, pp.439 - 443
Lee, Youngjin (Department of Radiological Science, Gachon University)
To improve the noise characteristics, software-based noise reduction algorithms are widely used in cadmium zinc telluride (CZT) pixelated semiconductor gamma camera system. The purpose of this study was to develop an improved median filtering algorithm using a thresholding method for noise reduction...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
M. Bocher, I.M. Blevis, L. Tsukerman, Y. Shrem, G. Kovalski, L. Volokh, A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential, Eur. J. Nucl. Med. Mol. Imag. 37 (2010) 1887-1902.
E.B. Sokole, A. Plachcinska, A. Britten, M.L. Georgosopoulou, W. Tindale, R. Klett, Routine quality control recommendations for nuclear medicine instrumentation, Eur. J. Nucl. Med. Mol. Imag. 37 (2010) 662-671.
H.O. Anger, Scintillation camera with multichannel collimators, J. Nucl. Med. 5 (1964) 515-531.
H. Wieczorek, A. Goedicke, Analytical model for SPECT detector concepts, IEEE Trans. Nucl. Sci. 53 (2006) 1102-1112.
J.H. Kim, Y. Choi, K.S. Joo, B.S. Shin, J.W. Chong, S.E. Kim, K.H. Lee, Y.S. Choe, B.T. Kim, Development of a miniature scintillation camera using an NaI(Tl) scintillator and PSPMT for scintimammograph, Phys. Med. Biol. 45 (2000) 3481-3488.
P. Yang, C.D. Harmon, F.P. Doty, J.A. Ohlhausen, Effect of humidity on scintillation performance in Na and Tl activated CsI crystals, IEEE Trans. Nucl. Sci. 61 (2014) 1024-1031.
G. Matsumoto, Y. Imura, H. Morii, A. Miyake, T. Aoki, Analysis of artifact with X-ray CT using energy band by photon counting CdTe detector, Nucl. Instrum. Methods Phys. Res. 621 (2010) 292-294.
F. Weng, S. Bagchi, Y. Zan, Q. Huang, Y. Seo, An energy-optimized collimator design for a CZT-based SPECT camera, Nucl. Instrum. Methods Phys. Res. 806 (2016) 330-339.
C. Scheiber, CdTe and CdZnTe detectors in nuclear medicine, Nucl. Instrum. Methods Phys. Res. 448 (2000) 513-524.
K. Ogawa, N. Ohmura, H. Iida, K. Nakamura, T. Nakahara, A. Kubo, Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector, Ann. Nucl. Med. 23 (2009) 763-770.
S. Lee, H.J. Kim, S.Y. Bae, Y. Lee, Experimental study of an easily controlled ultra-high-resolution pixel-matched parallel-hole collimator with a small cadmium zinc telluride pixelated gamma camera system, J. Med. Imag. Radiat. Sci. 47 (2016) 276-282.
Y.J. Lee, S.J. Park, S.W. Lee, D.H. Kim, Y.S. Kim, H.J. Kim, Comparison of photon counting and conventional scintillation detectors in a pinhole SPECT system for small animal imaging: Monte Carlo simulation studies, J. Kor. Phys. Soc. 62 (2013) 1317-1322.
Y.N. Choi, S. Lee, H.J. Kim, Reducing radiation dose by application of optimized low-energy X-ray filters to K-edge imaging with a photon counting detector, Phys. Med. Biol. 61 (2016) N35-N49.
B.S. Bhatia, S.L. Bugby, J.E. Lees, A.C. Perkins, A scheme for assessing the performance characteristics of small field-of-view gamma gameras, Phys. Med. 31 (2015) 98-103.
O. Gal, B. Dessus, F. Jean, F. Laine, C. Leveque, Operation of the CARTOGAM portable gamma camera in a photon-counting mode, IEEE Trans. Nucl. Sci. 48 (2001) 1198-1204.
H. Jeon, H. Kim, C.H. Lee, G. Cho, A simulation study on spatial resolution and noise power spectra of a URA-based multi-hole collimator in a small gamma camera, J. Nucl. Sci. Technol. 5 (2008) 530-533.
P. Chatterjee, P. Milanfar, Is denoising dead? IEEE Trans. Nucl. Sci. 19 (2010) 895-911.
J.T. Dobbins III, E. Samei, N.T. Ranger, Y. Chen, Intercomparison of methods for image quality characterization. II. Noise power spectrum, Med. Phys. 33 (2006) 1466-1475.
X. Zhang, Image denoising using local Wiener filter and its method noise, Optik 127 (2016) 6821-6828.
G. Gao, Y. Liu, An efficient three-stage approach for removing salt & pepper noise from digital images, Optik 126 (2015) 467-471.
S.H. Kang, K.Y. Kim, Y. Hwang, J.W. Hong, S.R. Baek, C.L. Lee, Y. Lee, A Monte Carlo simulation study for feasibility of total variation (TV) noise reduction technique using digital mouse whole body (MOBY) phantom image, Optik 156 (2018) 197-203.
Y. Lee, A.C. Lee, H.J. Kim, A Monte Carlo simulation study of an improved Kedge log-subtratction X-ray imaging using a photon counting CdTe detector, Nucl. Instrum. Methods Phys. Res. 830 (2016) 381-390.
I. Buvat, I. Castiglioni, Monte Carlo simulations in SPET and PET, Q. J. Nucl. Med. 46 (2002) 48-61.
S. Jan, D. Benoit, E. Becheva, T. Carlier, F. Cassol, P. Descourt, T. Frisson, L. Grevillot, L. Guigues, L. Maigne, C. Morel, Y. Perrot, N. Rehfeld, D. Sarrut, D.R. Schaart, S. Stute, U. Pietrzyk, D. Visvikis, N. Zahra, I. Buvat, GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy, Phys. Med. Biol. 56 (2011) 881-901.
C. Robert, N. Fourrier, D. Sarrut, S. Stute, P. Gueth, L. Grevillot, I. Buvat, PET-based dose delivery verification in proton therapy: a GATE based simulation study of five PET system designs in clinical conditions, Phys. Med. Biol. 58 (2013) 6867-6885.
S. Stute, T. Carlier, K. Cristina, C. Noblet, A. Martineau, B. Hutton, L. Barnden, I. Buvat, Monte Carlo simulations of clinical PET and SPECT scans: impact of the input data on the simulated images, Phys. Med. Biol. 56 (2011) 6441-6457.
S. Li, Q. Zhang, Z. Xie, Q. Liu, B. Xu, K. Yang, C. Li, Q. Ren, GATE simulation of a LYSO-based SPECT imager: validation and detector optimization, Nucl. Instrum. Methods Phys. Res. 773 (2015) 21-26.
D. Sarrut, M. Bardies, N. Boussion, N. Freud, S. Jan, J.M. Letang, G. Loudos, L. Mainge, S. Marcatili, T. Mauxion, P. Papadimitroulas, Y. Perrot, U. Pietrzyk, C. Robert, D.R. Schaart, D. Visvikis, I. Buvat, A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications, Med. Phys. 41 (2014), 064301-1-14.
C. Beijst, M. Elschot, M.A. Viergever, H.W.A.M. de jong, A parallel-cone collimator for high-energy SPECT, J. Nucl. Med. 56 (2015) 476-482.
N. Kubo, K. Tsuchiya, T. Shiga, S. Kojima, A. Suzuki, Y. Ueno, K. Kobashi, N. Tamaki, Collimator for variable sensitivity and spatial resolution without the need for exchange, IEEE Trans. Nucl. Sci. 61 (2014) 2489-2493.
Y. Lee, W. Kang, Performance evaluation of high-resolution square parallel-hole collimators with a CZT room temperature pixelated semiconductor SPECT system: a Monte Carlo simulation study, J. Instrum. (2015), https://doi.org/10.1088/1748-0221/10/07/T07004.
Y.J. Lee, H.J. Ryu, S.W. Lee, S.J. Park, H.J. Kim, Comparision of ultra-high-resolution parallel-hole collimator materials based on the CdTe pixelated semiconductor SPECT system, Nucl. Instrum. Methods Phys. Res. 713 (2013) 33-39.
B. Wang, Q. Pan, Soft-threshold histogram weighted filtering with correlativity for high density salt-pepper noise images, Acta Electron. Sin. 35 (2007) 1347-1351.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.