NTIS 바로가기방사선기술과학 = Journal of radiological science and technology, v.43 no.6, 2020년, pp.469 - 473
이현용 (부산가톨릭대학교 보건과학대학 방사선학과) , 김지수 (부산가톨릭대학교 보건과학대학 방사선학과)
Breast cancer is growing rapidly year by year and has the highest incidence since 2001. As a result, the interest in mammography for early detection of breast cancer is increasing. However, mammography is accompanied by radiation exposure and therefore it is necessary to reduce exposure dose through...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Park HS, Kim HJ, Lee CL, Cho HM, Yu AR. Standardization of the method of measuring Average Glandular Dose(AGD) and evaluation of the breast composition and thickness for AGD. Journal of Korean Society of Medical Physics. 2009;20(1):21-9.
Healthcare Bigdata Herb, (https://opendata.hira.or.kr)
Lee SH. A study on absorbed dose in the breast tissue using Geant4 simulation for mammography. Journal of Radiological Science and Technology. 2012;35(4):345-52.
Go KO. Assesment of subject dose in mammography and its implication in the screening practice. [master's thesis]. Perth: University of HanYang; 2004.
Kweon DC, Lee EM, Hong SM. Analysis of the compression force and thickness in the screening mammography. Journal of the Korean Institute of Industrial Engineers. 2002;606-10.
Jung HM, Jung JE, Hyun HJ, Won DY. The evaluation of space dose distribution for digital mammography equipment. Journal of the Korean Society of Radiology. 2015:9(1):59-63.
Lee JS, Ko SJ. Image quality and dose evaluation using monte carlo simulation digital mammography system. The Korean Contents Association. 2013;14(6):1-8.
Ministry of Food and Drug Safety. Guidelines for patient dose recommendation, in mammography. Radiation Safety Management Series. 16:1-26.
Sari F, Mahdavi SR, Anbiaee R, Shirazi A. The effect of breast reconstruction prosthesis on photon dose distribution in breast cancer radiotherapy. Iranian Journal of Medical Physics. 2017;14(4): 251-6.
Salehi Z, Balvasi E, Aziz M. A review of the recent Monte Carlo (MC) simulation for dosimetry in mammographic applications. Malaysian Journal of Medicine and Health Sciences. 2018;14:76-81.
Jung HR, Hong DH, Han BH. Testing and analysis of tube voltage current in the radiation generator for mammography. Journal of Radiological Science and Technology. 2014;37(1):1-6.
ICRP. Recommendation of the international commission on radiological protection. ICRP 103; 2007.
IAEA Safety Series No.115. International basic safety standards for protection against ionizing radiation and for the safety of radiaition sources; 1996.
Sin GS. Patient dose in mammography. Journal of Radiological Science and Technology. 2005;28(6): 293-9.
Kang JA, Kim KN, Jo YK. Average glandular dose according to compression breast thickness. Journal of The Korean Society of Radiological Imaging Technology. 2011:1-10.