최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기대한치과보철학회지 = The journal of Korean academy of prosthodontics, v.59 no.2, 2021년, pp.173 - 180
최재원 ((주)피엔유에드) , 채성기 (부산대학교 치의학전문대학원 치과보철학교실) , 허중보 (부산대학교 치의학전문대학원 치과보철학교실)
Purpose: The purpose of this study was to evaluate the retentive characteristics of the additional attachments used with implant bar attachment under repeated insertion/removal cycles. Materials and methods: The newly developed attachment and the commercially available attachment were investigated: ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
van Waas MA. The influence of clinical variables on patients' satisfaction with complete dentures. J Prosthet Dent 1990;63:307-10.
Yeo DH, Lim JH, Cho IH. A study on the changes in retention of clips used to retain implant-supported overdenture. J Korean Acad Prosthodont 1998;36:566-80.
Thomason JM, Heydecke G, Feine JS, Ellis JS. How do patients perceive the benefit of reconstructive dentistry with regard to oral health-related quality of life and patient satisfaction? A systematic review. Clin Oral Implants Res 2007;18:168-88.
Trakas T, Michalakis K, Kang K, Hirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent 2006;15:24-34.
Zitzmann NU, Marinello CP. Treatment plan for restoring the edentulous maxilla with implant-supported restorations: removable overdenture versus fixed partial denture design. J Prosthet Dent 1999;82:188-96.
Watson CJ, Tinsley D, Sharma S. Implant complications and failures: the complete overdenture. Dent Update 2001;28:234-8, 240.
van Kampen F, Cune M, van der Bilt A, Bosman F. Retention and postinsertion maintenance of barclip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res 2003;14:720-6.
Bakke M, Holm B, Gotfredsen K. Masticatory function and patient satisfaction with implant-supported mandibular overdentures: a prospective 5-year study. Int J Prosthodont 2002;15:575-81.
Naert I, Gizani S, Vuylsteke M, van Steenberghe D. A 5-year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: Peri-implant outcome. Clin Oral Implants Res 1998;9:170-7.
Walton JN, MacEntee MI, Glick N. One-year prosthetic outcomes with implant overdentures: a randomized clinical trial. Int J Oral Maxillofac Implants 2002;17:391-8.
Schneider AL, Kurtzman GM. Restoration of divergent free-standing implants in the maxilla. J Oral Implantol 2002;28:113-6.
Kurtzman GM. Lab techniques for use of the locator attachmentin bar-overdenture applications. Team-Work 2008;1:72-8.
Chiu LPY, Vitale ND, Petridis H, McDonald A. The Effect of Different Water Temperatures on Retention Loss and Material Degradation of Locator Attachments. J Prosthodont 2017;26:537-44.
Choi JW, Bae JH, Jeong CM, Huh JB. Retention and wear behaviors of two implant overdenture studtype attachments at different implant angulations. J Prosthet Dent 2017;117:628-35.
Choi JW, Choi KH, Chae HJ, Chae SK, Bae EB, Lee JJ, Lee SH, Jeong CM, Huh JB. Load-bearing capacity and retention of newly developed micro-locking implant prosthetic system: An in vitro pilot study. Materials (Basel) 2018;11:564.
Choi JW, Lee JJ, Bae EB, Huh JB. Implant-supported fixed dental prosthesis with a microlocking implant prosthetic system: A clinical report. J Prosthet Dent 2020;123:15-9.
Choi JW, Song CH, Huh JB: Implant-supported fixed dental prostheses with new retention type using zirconia ball and nickel-titanium spring. Implantology 2019;23:16-24.
Oh SC, Han JS, Kim MJ. Implant supported overdenture using milled titanium bar with locator(R) attachment on fully edentulous maxillae : A case report. J Dent Rehab Appl Sci 2011;27:223-31.
Son CY, Jeong CM, Jeon YC, Lim JS, Jeong HC. Comparative studies of retentive forces in maxillary overdenture bar attachments. J Korean Acad Prosthodont 2005;43:650-61.
Michelinakis G, Barclay CW, Smith PW. The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: initial retention values. Int J Prosthodont 2006;19:507-12.
ELsyad MA, Dayekh MA, Khalifa AK. Locator versus bar attachment effect on the retention and stability of implant-retained maxillary overdenture: An in vitro study. J Prosthodont 2019;28:e627-36.
Pigozzo MN, Mesquita MF, Henriques GE, Vaz LG. The service life of implant-retained overdenture attachment systems. J Prosthet Dent 2009;102:74-80.
Burns DR, Unger JW, Elswick RK Jr, Beck DA. Prospective clinical evaluation of mandibular implant overdentures: Part I-Retention, stability, and tissue response. J Prosthet Dent 1995;73:354-63.
Naert I, Gizani S, Vuylsteke M, Van Steenberghe D. A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: prosthetic aspects and patient satisfaction. J Oral Rehabil 1999;26:195-202.
Gonuldas F, Tokar E, Ozturk C. Evaluation of the retention characteristics of various stud attachment systems for implant retained overdenture. Acta Bioeng Biomech 2018;20:135-41.
Srinivasan M, Schimmel M, Badoud I, Ammann P, Herrmann FR, Muller F. Influence of implant angulation and cyclic dislodging on the retentive force of two different overdenture attachments - an in vitro study. Clin Oral Implants Res 2016;27:604-11.
Williams BH, Ochiai KT, Hojo S, Nishimura R, Caputo AA. Retention of maxillary implant overdenture bars of different designs. J Prosthet Dent 2001;86:603-7.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.