최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국융합신호처리학회논문지 = Journal of the Institute of Convergence Signal Processing, v.22 no.2, 2021년, pp.51 - 56
최원석 (금오공과대학교 의료산업 혁신대학사업)
The brachial systolic blood pressure and pulse pressure are the predictors of cardiovascular disease in individuals over 50 years of age. As the stiffness increases, the reflex amplitude and pressure in the late systole increase, resulting in an increase in left ventricular load and myocardial oxyge...
Frank, O., 1899, "Die Grundform des arterielen Pulses erste Abhandlung: mathematische Analyse," Z. Biol., 37, pp. 483-526.
Stergiopulos, N., Meister, J. J., and Westerhof, N., 1995, "Evaluation of methods for the estimation of total arterial compliance," Am. J. Physiol., 268 (Heart Circ Physiol 37), pp. H1540-H1548.
Burattini, R., and Gnudi, G., 1982, "Computer identification of models for the arterial tree input impedance: comparison between two new simple models and first experimental results," Med. Biol. Eng. Comput., 20, pp. 134-144.
Stergiopulos, N., Westerhof, B. E., and Westerhof, N., 1999, "Total arterial inertance as the fourth element of the windkessel model," Am. J. Physiol., 276 (Heart Circ Physiol 45), pp. H81-H88.
Segers, P., Rietzsxhel, E. R., De Buyzere, M. L., Stergiopulos, N., Westerhof, N., Van Bortel, L. M., Gillebert, T., and Verdonck, P. R., 2008, "Three- and four-element Windkessel models: assessment of their fitting performance in a large cohort of healthy middle-aged individuals," Proc. IMchE, 222, pp. 417-428.
Westerhof, N., Lankhaar, J. W., and Westerhof, B. E., 2009, "The arterial Windkessel," Med. Biol. Eng. Comput., 47, pp. 131-141.
Qiao, Y., Fan, J., Ding, Y., Zhu, T, and Luo, K., 2019, "A primary computational fluid dynamics study of preand post-TEVAR with intentional left subclavian artery coverage in a type B aortic dissection", J. Biomech. Eng., 141, pp. 111002.
Zahedi, E., Chellappan, K., Ali, M. A. M., 2007, "Singh, H. Analysis of the Effect of Ageing on Rising Edge Characteristics of the Photoplethysmogram using a Modified Windkessel Model," Cardiovasc. Eng., 7, pp. 172-181.
Burattini, R., and Gnudi, G., 1982, "Computer identification of models for the arterial tree input impedance: comparison between two new simple models and first experimental results," Med. Biol. Eng. Comput., 20, pp. 134-144.
Benetos, A., Safar, M., Rudnichi, A., Smulyan, H., Richard, J. L., Ducimetieere, P., and Guize, L., 1997, "Pulse pressure: a predictor of long-term catdiovascular mortality in a French male population," Hypertension, 30, pp. 1410-1415.
Mitchell, G. F., Moye, L. A., Braunwald, E., Rouleau, J. L., Bernstein, V., Geltman, E.M., Flaker, G. C., and Pfeffer, M. A., 1997, "Sphygmomanometrically determined pulse pressure is a powerful independent predictor of recurrent events after myocardial infarction in patients with impaired left ventricular function SAVE investigators. Survival and ventricular enlargement," Circulation, 96, pp. 4254-4260.
Wilmer W. Nichols, Scott J. Denardo, Ian B. Wilkinson, Carmel M. McEniery, John Cockcroft, Michael F. O'Rourke,2008, "Effects of Arterial Stiffness, Pulse Wave Velocity, and Wave Reflections on the Central Aortic Pressure Waveform",The Journal of hypertension, pp.295-303.
Shirouzu, S., Shirouzu, E., Tsuda, Y., and Sugano, H., 1998, "Circulatory parameter extraction from digital plethysmogram I: waveform analysis of digital plethysmogram," Proceedings of the 20th annual international conference of the IEEE Engineering in medicine and biology society, 20, pp. 3087-3089.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.