최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기방사선기술과학 = Journal of radiological science and technology, v.44 no.3, 2021년, pp.173 - 181
정민규 (충북대학교병원 영상의학과) , 성열훈 (청주대학교 보건의료과학대학 방사선학과)
The purpose of this study was to reduce dose while maintaining image quality during digital radiographic examination of paranasal sinus by using the automatic exposure control (AEC) system. The tube voltage was set as six stages that increased by about 10 kVp to 70 kVp, 81 kVp, 90 kVp, 102 kVp, 109 ...
Chiu P, Chen J, Chang C, Wei J. The diagnostic value of sinus radiography in the evaluation of sinusitis. Journal of Chin J Radiology. 2010;35(2):143-8.
Lee JS, Ko SJ, Kang SS, Kim JH, Kim DH, Kim CS. Evaluation of image quality using automatic exposure control & sensitivity in the digital chest image. Journal of The Korea Contents Society. 2013;13(8):275-83.
Hamer OW, Sirlin CB, Strotzer M, Borisch I, Zorger N, Feuerbach S, et al. Chest radiography with a flat-panel detector: Image quality with dose reduction after copper filtration. radiology. 2005;237(2):691-700.
ICRP. Statement on Tissue Reactions. Approved by the Commission on April. 2007.
Hwang JH, Lee KB. A study on the quantitative analysis method through the absorbed dose and the histogram in the performance evaluation of the detector according to the sensitivity change of Auto Exposure Control(AEC) in digital radiography. Journal of The Korea Contents Society. 2018;18(1):232-40.
Seibert JA. Digital radiography: Image quality and radiation dose. Health Physics. 2008;95(5):586-98.
Schaefer-Prokop C, Neitzel U, Venema HW, Uffmann M, Prokop M. Digital chest radiography: An update on modern technology, dose containment and control of image quality. European Radiology. 2008;18(9):1818-30.
Lee JS, Park HH. Evaluation on organ dose and image quality by changing kVp and ion chamber combination while taking digital chest lateral decubitus PA projection. Journal of The Korea Contents Society. 2015;15(1):316-23.
Hawking N, Elmore A. Effects of AEC chamber selection on patient dose and image quality. Radiologic Technoloy. 2009;80(5):411-20.
Kim SC, Lee HK, Lee YS, Cho JH. Evaluation of automatic exposure control system chamber for The dose optimization when examining pelvic in digital radiography. Journal of X-ray Science and Technology. 2015;23(3):321-30.
Jeong MG, Seoung YH. Effects of field configuration shielding area and changing of density and sensitivity on tube current and image quality in automatic exposure control system. Journal of Radiological Science and Technology. 2020;14(5):635-42.
Lee JS, Choi BW, Kim SH, Kim YM, Shim JN, Ahn HS, et al. Effect of automatic exposure control marker with chest radiography in radiation reduction. Korean Society of Radiological Science. 2014;37(33):177-85.
Hwang JH, Ahn CJ, Lee KB. A study on the dynamic range performance evaluation method of detector with variation of tube voltage and automatic exposure control in digital radiography: Focused on the dynamic step wedge and histogram evaluation. Journal of The Korea Contents Society. 2019;19(4):368-80.
Huang W, Van Metter R, Yang CYJ, Yorkston J. Configuration of AEC kVp dependence for digital radiography systems. Progress in Biomedical Optics and Imaging Proceedings Series. 2007;6510(1):651017.
Bowden L, Faulkner R, Clancy C, Gallagher A, Devine M, Gorman D, et al. Doses under Automatic Exposure Control (AEC) for direct digital radiographic (DDR) X-ray systems. Radiation Protection Dosimetry. 2011;147(1-2):210-4.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.