최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기대한치과보철학회지 = The journal of Korean academy of prosthodontics, v.59 no.3, 2021년, pp.341 - 349
송준범 (단국대학교 치과대학 치과보철학교실) , 이종혁 (단국대학교 치과대학 치과보철학교실) , 하승룡 (단국대학교 치과대학 치과보철학교실) , 최유성 (단국대학교 치과대학 치과보철학교실) , 최선영 (단국대학교 치과대학 치과보철학교실)
The evaluation of occlusion using digital methods is easier and simpler in terms of recording, comparison, analysis, and objectivity compared to existing methods such as articulating paper and occlusion foil. The purpose of this case report was utilizing the digital method for evaluating occlusion. ...
Chochlidakis KM, Papaspyridakos P, Geminiani A, Chen CJ, Feng IJ, Ercoli C. Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis. J Prosthet Dent 2016; 116:184-90.
Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 2008;204:505-11.
Real-Voltas F, Romano-Cardozo E, Figueras-Alvarez O, Brufau-de Barbera M, Cabratosa-Termes J. Comparison of the marginal fit of cobalt-chromium metal-ceramic crowns fabricated by CAD/CAM techniques and conventional methods at three production stages. Int J Prosthodont 2017;30:304-5.
Michelinakis G, Apostolakis D, Tsagarakis A, Kourakis G, Pavlakis E. A comparison of accuracy of 3 intraoral scanners: A single-blinded in vitro study. J Prosthet Dent 2020;124:581-8.
De Boever JA, Carlsson GE, Klineberg IJ. Need for occlusal therapy and prosthodontic treatment in the management of temporomandibular disorders. Part I. Occlusal interferences and occlusal adjustment. J Oral Rehabil 2000;27:367-79.
Hutzen D, Rebau M, Kordass B. Clinical reproducibility of GEDAS--"Greifswald Digital Analyzing System" for displaying occlusal contact patterns. Int J Comput Dent 2006;9:137-42.
Kerstein RB, Radke J. Clinician accuracy when subjectively interpreting articulating paper markings. Cranio 2014;32:13-23.
Saad MN, Weiner G, Ehrenberg D, Weiner S. Effects of load and indicator type upon occlusal contact markings. J Biomed Mater Res B Appl Biomater 2008;85:18-22.
Lee H, Cha J, Chun YS, Kim M. Comparison of the occlusal contact area of virtual models and actual models: a comparative in vitro study on Class I and Class II malocclusion models. BMC Oral Health 2018;18:109.
Afrashtehfar KI, Qadeer S. Computerized occlusal analysis as an alternative occlusal indicator. Cranio 2016;34:52-7.
Fixed prosthodontics faculty counsil. Fixed prosthodontics principles and clinics. 2nd ed. Seoul; Daehan Narae Publishing; 2017. p.47-8.
Aquilino SA, Caplan DJ. Relationship between crown placement and the survival of endodontically treated teeth. J Prosthet Dent 2002;87:256-63.
Silvestri AR Jr, Singh I. Treatment rationale of fractured posterior teeth. J Am Dent Assoc 1978;97:806-10.
Ayuso-Montero R, Mariano-Hernandez Y, Khoury-Ribas L, Rovira-Lastra B, Willaert E, Martinez-Gomis J. Reliability and validity of T-scan and 3D intraoral scanning for measuring the occlusal contact area. J Prosthodont 2020;29:19-25.
Solaberrieta E, Etxaniz O, Otegi JR, Brizuela A, Pradies G. Customized procedure to display T-scan occlusal contacts. J Prosthet Dent 2017;117:18-21.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.