최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국방사선학회 논문지 = Journal of the Korean Society of Radiology, v.15 no.4, 2021년, pp.491 - 498
곽종혁 (양산부산대학교병원 영상의학과) , 김아연 (인제대학교 일반대학원 보건학과) , 김경립 (양산부산대학교병원 신경외과) , 조희정 (부산과학기술대학교 의무행정과) , 문성진 (부산과학기술대학교 재활운동 건강과) , 길상형 (양산부산대학교병원 핵의학과) , 이종규 (부경대학교 물리학과)
In this study, the effective dose was measured using the PCXMC v2.0 program by examining the conditions used to set the diagnostic reference level for intraoral imaging recommended by the government, and the effect of the Al additive filter was confirmed. In oral imaging, the largest effective dose ...
NCRP, "Ionizing radiation exposure of the populationof the United States. Bethesda, MD," National Council on Radiation Protection and Measurements, Report No. 160, 2009.
D. U. Seong, "A study on patient dose history management in the field of radiology", Ministry of Food and Drug Safety research report, Vol. 111, No. 72, pp. 852, 2013.
ICRP, "1990 recommendations of the international commission on radiological protection", International Commission on Radiological Protection, ICRP Publication 60, Ann ICRP 21 (1-3), 1991.
ICRP, "The 2007 recommendations of the International Commission on Radiological Protection New York, NY", International Commission on Radiological Protection, ICRP Publication 103, 2007.
M. J. Oh, J. W. Hong, Y. J. Lee, "Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography", Journal of the Korean Society of Radiology, Vol. 13, No. 01, pp. 81-86, 2019. http://dx.doi.org/10.7742/jksr.2019.13.1.81
N. G. Choi, H. J. Seong, J. S. Jeon, Y. H. Kim, D. O. Seong, "A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography", Korean Association for Radiation Protection, Vol. 37, No. 01, pp. 25-34, 2012. https://doi.org/10.14407/jrp.2012.37.1.025
Guidelines for the reference level of diagnosis in computed tomography, Korea Disease Control and Prevention Agency, 2017.
Elizabeth K. Cahoon, Rui Zhang, Steven L. Simon, Andre Bouville, Ruth M. Pfeiffer, "Projected Cancer Risks to Residents of New Mexico from Exposure to Trinity Radioactive Fallout", Health Physics Society, Vol. 119, No. 4, pp. 478-493, 2020. http://dx.doi.org/10.1097/HP.0000000000001333
Y. K. Lee, M. S. Yon, D.H. Kim, "The study of X-ray detection characteristic and fabrication photoconductor film thickness for Screen printing method", Journal of the Korean Society of Radiology, Vol. 3, No. 2, pp. 11-16, 2009
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.