NTIS 바로가기한국심리학회지 : 법, v.12 no.2, 2021년, pp.151 - 169
In the P300-based concealed information test, most commonly used methods to detect whether a subject is lying are the bootstrapped amplitude difference (BAD) and the bootstrap correlation difference (BCD). Previous studies comparing the accuracy of the two methods reported inconsistent results. Most...
김혜민, 송인욱, 장은희, 김현택 (2020). 설문기반 대응방안을 사용한 복합시행 프로토콜의 재평가. 한국심리학지: 법, 11(1), 89-115.
엄진섭, 박광배 (2014). P300 숨긴정보검사에서 시행수가 검사결과에 미치는 영향. 한국심리학회지: 사회 및 성격, 28(3), 61-79.
전하정, 손진훈, 엄진섭 (2020). P300 숨긴정보 검사에서 순열 검증의 정확도. 한국심리학회지: 인지 및 생물, 32(1), 69-83.
정은경, 김영윤 (2013). P300-기반 유죄지식검사의 탐지정확률 비교. 한국심리학회지: 인지 및 생물, 25(1), 75-92.
Ahad, N. A., Abdullah, S., & Lai, C. H. (2012). Relative power performance of t-test and bootstrap procedure for two-sample. Pertanika Journal of Science & Technology, 20(1), 43-52.
Allen, J. J., & Iacono, W. G. (1997). A comparison of methods for the analysis of event potentials in deception detection. Psychophysiology, 34(2), 234-240.
Alsufyani, A. (2017, August). A comparison of classification algorithms for Event Related Potentials. In 2017 4th International Conference on Computer Applications and Information Proces ing Technology (CAIPT) (pp. 1-5). IEEE.
Cohen, J., & Polich, J. (1997). On the number of trials needed for P300. International Journal of Psychophysiology, 25(3), 249-255.
Dwivedi, A. K., Mallawaarachchi, I., & Alvarado, L. A. (2017). Analysis of small sample size studies using nonparametric bootstrap test with pooled resampling method. Statistics in Medicine, 36(14), 2187-2205.
Farwell, L. A. & Donchin, E. (1991). The truth will out: Interrogative polygraphy ("lie detection") with event-related Potentials. Psychophysiology, 28(5), 531-547.
Farwell, L. A., Richardson, D. C., & Richardson, G. M. (2013). Brain fingerprinting field studies comparing P300-MERMER and P300 brainwave responses in the detection of concealed information. Cognitive Neurodynamics, 7(4), 263-299.
Farwell, L. A., Richardson, D. C., Richardson, G. M., & Furedy, J. J. (2014). Brain fingerprinting classification concealed information test detects US Navy military medical information with P300. Frontiers in neuroscience, 8, 410.
Janssen, A., & Pauls, T. (2005). A Monte Carlo comparison of studentized bootstrap and permutation tests for heteroscedastic twosample problems. Computational Statistics, 20(3), 369-383.
Johnson, R. (1993). On the neural generators of the P300 component of the event-related potential. Psychophysiology, 30(1), 90-97.
Konietschke, F., & Pauly, M. (2014). Bootstrapping and permuting paired t-test type statistics. Statistics and Computing, 24(3), 283-296.
Luck, S. J. (2014). An introduction to the event-related potential technique. MIT press.
Meixner, J. B., & Rosenfeld, J. P. (2011). A mock terrorism application of the P300 based concealed information test. Psychophysiology, 48(2), 149-154.
Mertens, R. & Allen, J. J. (2008). The role of psychophysiology in forensic assessments: Deception detection, ERPs, and virtual reality mock crime scenarios. Psychophysiology, 45(2), 286-298.
Polich, J. (2007). Updating P300: an integrative theory of P3a and P3b. Clinical neurophysiology, 118(10), 2128-2148.
Rosenfeld, J. P. (2005). Brain fingerprinting: A critical analysis. The Scientific Review of Mental Health Practice, 4(1), 20-37.
Rosenfeld, J. P. (2011). P300 in detecting concealed information. In B. Verschuere, G. Ben-Shakhar, & E. Meijer (Eds.), Memory detection: Theory and application of the concealed information test (pp. 63-89). Cambridge, UK: Cambridge University Press
Rosenfeld, J. P., Hu, X., & Pederson, K. (2012). Deception awareness improves P300-based deception detection in concealed information tests. International Journal of Psychophysiology, 86(1), 114-121.
Rosenfeld, J. P., Labkovsky, E., Winogard, M., Lui, M. A., Vandenboom, C., & Chedid, E. (2008). The complex trial protocol(CTP): A new, countermeasure-resistant, accurate, P300-based method for detection of concealed information. Psychophysiology, 45(6), 906-919.
Rosenfeld, J. P., Soskins, M., Bosh, G., & Ryan, A. (2004). Simple, effective countermeasures to P300 based tests of detection of concealed information. Psychophysiology, 41(2), 205-219.
Semlitsch, H. V., Anderer, P., Schuster, P., & Presslich, O. (1986). A solution for reliable and valid reduction of ocular artifacts, applied to the P300 ERP. Psychophysiology, 23(6), 695-703.
Soskins, M., Rosenfeld, J. P., & Niendam, T. (2001). Peak-to-peak measurement of P300 recorded at 0.3 Hz high pass filter settings in intraindividual diagnosis: complex vs. simple paradigms. International Journal of Psychophysiology, 40(2), 173-180.
Yeung, N., Bogacz, R., Holroyd, C. B., & Cohen, J. D. (2004). Detection of synchronized oscillations in the electroencephalogram: an evaluation of methods. Psychophysiology, 41(6), 822-832.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.