NTIS 바로가기한국건축시공학회지 = Journal of the Korea Institute of Building Construction, v.21 no.5, 2021년, pp.483 - 493
신상욱 (Department of Architectural Engineering, Pusan national University) , 류종우 (Department of Architectural Engineering, Pusan national University) , 정희웅 (Department of Architectural Design, Dongseo University) , 김대영 (Department of Architectural Engineering, Pusan national University)
Urban overcrowding has created an explosive supply and demand for high-rise buildings. High-rise buildings are contributing to enhancing the image of the city by serving as focal points, but due to the stack effect, malfunction of elevator doors, difficulties in opening and closing the doors and win...
Jo JH, Yang IH, Yeo MS, Kim KW. A case study on the field measurement and reduction of the stack effect in high-rise buildings. Journal of the Architectural Institute of Korea Planning & Design. 2002 Jul;18(7):169-76.
Lee JH, Lee JH, Song DS. A study on the contaminant dispersion by stack effect in high-rise residential building. KIEAE Journal. 2010 Jun;10(3):97-102.
Kim JS, Lee EP. Study on the method of stack effect mitigation by the elevator shaft pressurization at high-rise buildings. Fire Science and Engineering. 2011 Dec;25(6):178-83.
Yu JY, Song KD, Cho DW. Design procedure for minimizing stack effect problems in the tall office building connected with the row-rise shopping center. Journal of the Architectural Institute of Korea Planning & Design. 2010 Mar;26(3):227-34.
Lee WH, Koo SH, Jo JH. Field measurements and evaluation of noises caused by stack effect at the elevator door in high-rise buildings. Journal of Korean Institute of Architectural Sustainable Environment and Building Systems. 2015 Aug;9(4):312-8.
Lee JH, Lim HW. Song JE, Lee JH, Song DS. A study on the quantitative characteristics of countermeasures on stock effect in high-rise building. Journal of the Architectural Institute of Korea Planning & Design. 2009 Oct;29(1):849-52.
Jo JH, Yeo MS, Yang IH, Kim KW. Field measurement and simulation of the stack effect in high-rise building. Autumn Annual Conference of AIK. 2001 Oct 27; Asan, Korea. Seoul (Korea): Journal of the Architectural Institute of Korea(JAIK); 2001. p. 965-8.
Seo BY, Choi JH, Hong WH. Prediction of smoke diffusion and minimizing methods of stack effect considering the status of opening in a high-rise building. Journal of the Architectural Institute of Korea Planning & Design. 2010 Sep; 26(9):259-66.
Jung YW, Yoon JO. The simulation on stack effect of high-rise residential complex. Autumn Annual Conference of AIK. 2017 Oct 25-27; Kyongju, Korea. Seoul(Korea): Journal of the Architectural Institute of Korea(JAIK); 2017. p. 526-9.
Kim KH. The effect of the stack effect of high-rise buildings on the diffusion of indoor pollutants. Magazine of the SAREK. 2008 Nov;37(11):14-9.
Shin HK, Jo JH, Kim KW. Field measurements of stack pressure profiles in the high-rise office building. Autumn Annual Conference of AIK. 2009 Oct 23-24; Chuncheon, Korea. Seoul(Korea): Journal of the Architectural Institute of Korea(JAIK); 2009. p. 845-8.
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.