최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기대한치과보철학회지 = The journal of Korean academy of prosthodontics, v.60 no.1, 2022년, pp.119 - 126
황수현 (부산대학교 치의학전문대학원 치과보철학교실 및 치의생명과학 교육연구팀) , 배은빈 (부산대학교 치의학전문대학원 치과보철학교실 및 치의생명과학 교육연구팀) , 조원탁 (부산대학교 치의학전문대학원 치과보철학교실 및 치의생명과학 교육연구팀) , 허중보 (부산대학교 치의학전문대학원 치과보철학교실 및 치의생명과학 교육연구팀)
Mini-implant has been reported as an alternative method to conventional diameter implants in the treatment of mandibular anterior region with narrow ridge. However, one-piece type mini-implant showed biological and technical complications, such as peri-implantitis by residual cement and prosthetic d...
Galindo-Moreno P, Nilsson P, King P, Worsaae N, Schramm A, Padial-Molina M, Maiorana C. Clinical and radiographic evaluation of early loaded narrow-diameter implants: 5-year follow-up of a multicenter prospective clinical study. Clin Oral Implants Res. 2017;28:1584-91.
Griffitts TM, Collins CP, Collins PC. Mini dental implants: an adjunct for retention, stability, and comfort for the edentulous patient. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2005;100:e81-4.
Buser D, Mericske-Stern R, Bernard JP, Behneke A, Behneke N, Hirt HP, Belser UC, Lang NP. Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997;8:161-72.
Klein MO, Schiegnitz E, Al-Nawas B. Systematic review on success of narrow-diameter dental implants. Int J Oral Maxillofac Implants 2014;29:43-54.
Kim YK, Yeo IS, Yi YJ, Kim UK, Moon KN, Jeon SJ, Cho YS, Yun PY. Multicentric retrospective clinical study on the clinical application of mini implant system. J Korean Assoc Oral Maxillofac Surg 2010;36:325-30.
Goiato MC, Sonego MV, Pellizzer EP, Gomes JML, da Silva EVF, Dos Santos DM. Clinical outcome of removable prostheses supported by mini dental implants. A systematic review. Acta Odontol Scand 2018;76:628-37.
Park JH, Lee JY, Ryu JJ, Shin SW. Mandibular implant supported overdentures with two different mini-implant systems: A case report. J Korean Acad Prosthodont 2016;54:267-72.
Wu AY, Hsu JT, Chee W, Lin YT, Fuh LJ, Huang HL. Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses. J Formos Med Assoc 2016;115:794-800.
Parize HN, Bohner LOL, Gama LT, Porporatti AL, Mezzomo LAM, Martin WC, Goncalves TMSV. Narrow-diameter implants in the anterior region: A meta-analysis. Int J Oral Maxillofac Implants 2019;34:1347-58.
Parel SM, Schow SR. Early clinical experience with a new one-piece implant system in single tooth sites. J Oral Maxillofac Surg 2005;63:2-10.
Jackson BJ. Small diameter implants: specific indications and considerations for the posterior mandible: a case report. J Oral Implantol 2011;37:156-64.
Flanagan D, Mascolo A. The mini dental implant in fixed and removable prosthetics: a review. J Oral Implantol 2011;37:123-32.
Vigolo P, Givani A. Clinical evaluation of single-tooth mini-implant restorations: a five-year retrospective study. J Prosthet Dent 2000;84:50-4.
Reddy MS, O'Neal SJ, Haigh S, Aponte-Wesson R, Geurs NC. Initial clinical efficacy of 3-mm implants immediately placed into function in conditions of limited spacing. Int J Oral Maxillofac Implants 2008;23:281-8.
Mohan CS, Harinath P, Cholan PK, Kumar DL. Predictable aesthetic outcome with immediate placement and early loading of one piece mini implant - A 5 year follow-up case report. J Int Oral Health 2014;6:132-5.
Huh JB, Ko SM. The comparative study of thermal inductive effect between internal connection and external connection implant in abutment preparation. J Korean Acad Prosthodont 2007;45:60-70.
Nogueira LB, Moura CD, Francischone CE, Valente VS, Alencar SM, Moura WL, Soares Martins GA. Fracture strength of implant-supported ceramic crowns with customized zirconia abutments: screw retained vs. cement retained. J Prosthodont 2016;25:49-53.
Abduo J, Lyons K, Bennamoun M. Trends in computer-aided manufacturing in prosthodontics: a review of the available streams. Int J Dent 2014;2014:783948.
Song SR, Park KM, Jung BY. Fracture strength analysis of titanium insert-reinforced zirconia abutments according to the axial height of the titanium insert with an internal connection. PLoS ONE 2021;16:e0249208.
Jeong B, Lee Y, Hong SJ, Paek J, Noh K, Pae A, Kim HS, Kwon KR. Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height. J Korean Acad Prosthodont 2021;59:27-35.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.