NTIS 바로가기한국음향학회지= The journal of the acoustical society of Korea, v.41 no.1, 2022년, pp.76 - 86
Yun, Donghyeon (Department of Speech, Language and Hearing Sciences, Indiana University Bloomington) , Shen, Yi (Department of Speech and Hearing Sciences, University of Washington) , Zhang, Zhuohuang (Department of Speech, Language and Hearing Sciences, Indiana University Bloomington)
Personal hearing devices, such as hearing aids, may be fine-tuned by allowing the users to conduct self-adjustment. Two self-adjustment procedures were developed to collect the listener preferred gains in six octave-frequency bands from 0.25 kHz to 8 kHz. These procedures were designed to allow rapi...
1. Keidser G , Dillon H , Flax M , Ching T , and Brewer S , “ The NAL-NL2 prescription procedure ,” Audiol. Res . 1 , 88 – 90 ( 2011 ).
2. Seewald R , Moodie S , Scollie S , and Bagatto M , “ The DSL method for pediatric hearing instrument fitting: Historical perspective and current issues ,” Trends Amplif . 9 , 145 – 157 ( 2005 ). 16424944
3. Moore BC , Glasberg BR , and Stone MA , “ Development of a new method for deriving initial fittings for hearing aids with multi-channel compression: CAMEQ2-HF ,” Int. J. Audiol . 49 , 216 – 227 ( 2010 ). 20151930
4. Lopez-Poveda EA , Johannesen PT , Pérez-González P , Blanco JL , Kalluri S , and Edwards B , “ Predictors of hearing-aid outcomes ,” Trends Hear . 21 , 2331216517730526 ( 2017 ).
5. Mueller HG , Hornsby BW , and Weber JE , “ Using trainable hearing aids to examine real-world preferred gain ,” J. Am. Acad. Audiol . 19 , 758 – 773 ( 2008 ). 19358456
6. Mackersie C , Boothroyd A , and Lithgow A , “ A “Goldilocks” approach to hearing-aid self-fitting : Ear-canal output and speech intelligibility index ,” Ear Hear . 40 , 107 ( 2019 ). 29894379
7. Convery E , Keidser G , Seeto M , and McLelland M , “ Evaluation of the self-fitting process with a commercially available hearing aid ,” J. Am. Acad. Audiol . 28 , 109 – 118 ( 2017 ). 28240978
8. Boothroyd A and Mackersie C , “ A “Goldilocks” approach to hearing-aid self-fitting: User interactions ,” Am. J. Audiol . 26 , 430 – 435 ( 2017 ). 29049625
9. Boymans M and Dreschler WA , “ Audiologist-driven versus patient-driven fine tuning of hearing instruments ,” Trends Amplif . 16 , 49 – 58 ( 2012 ). 22143874
10. Cox RM and Alexander GC , “ Preferred hearing aid gain in everyday environments ,” Ear Hear . 12 , 123 – 126 ( 1991 ). 2065837
11. Dreschler WA , Keidser G , Convery E , and Dillon H , “ Client-based adjustments of hearing aid gain: The effect of different control configurations ,” Ear Hear . 29 , 214 – 227 ( 2008 ). 18490863
12. Keidser G , Brew C , Brewer S , Dillon H , Grant F , and Storey L , “ The preferred response slopes and two-channel compression ratios in twenty listening conditions by hearing-impaired and normal-hearing listeners and their relationship to the acoustic input ,” Int. J. Audiol . 44 , 656 – 670 ( 2005 ). 16379494
13. Keidser G , Dillon H , and Convery E , “ The effect of the base line response on self-adjustments of hearing aid gain ,” J. Acoust. Soc. Am . 124 , 1668 – 1681 ( 2008 ). 19045657
14. Kuk FK and Lau CC , “ The application of binomial probability theory to paired comparison judgments ,” Am. J. Audiol . 4 , 37 – 42 ( 1995 ).
15. Nelson PB , Perry TT , Gregan M , and Van Tasell D , “ Self-adjusted amplification parameters produce large between-subject variability and preserve speech intelligibility ,” Trends Hear . 22 , 2331216518798264 ( 2018 ).
16. Kuk FK and Pape NM , N. M, “ The reliability of a modified simplex procedure in hearing aid frequency-response selection ,” J Speech Lang Hear Res . 35 , 418 – 429 ( 1992 ).
17. Sabin AT , Van Tasell DJ , Rabinowitz B , and Dhar S , “ Validation of a self-fitting method for over-the-counter hearing aids ,” Trends Hear . 24 , 233121 6519900589 ( 2020 ).
18. Byrne D and Dillon H , “ The National Acoustic Laboratories’(NAL) new procedure for selecting the gain and frequency response of a hearing aid ,” Ear Hear . 7 , 257 – 265 ( 1986 ). 3743918
19. Zakis JA , Dillon H , and McDermott HJ , “ The design and evaluation of a hearing aid with trainable amplification parameters ,” Ear Hear . 28 , 812 – 830 ( 2007 ). 17982368
20. Chalupper J and Powers TA , “ Changing how gain is selected: The benefits of combining datalogging and a learning VC ,” Hear. Rev . 13 , 46 ( 2006 ).
21. Vaisberg JM , Beaulac S , Glista D , Macpherson EA , and Scollie SD , “ Perceived sound quality dimensions influencing frequency-gain shaping preferences for hearing aid-amplified speech and music ,” Trends Hear . 25 , 2331216521989900 ( 2021 ).
22. Jespersen CT and Møller KN , “ Reliability of real ear insertion gain in behind-the-ear hearing aids with different coupling systems to the ear canal ,” Int. J. Audiol . 52 , 169 – 176 ( 2013 ). 23301659
23. Punch JL , Montgomery AA , Schwartz DM , Walden BE , Prosek RA , and Howard MT , “ Multi-dimensional scaling of quality judgments of speech signals processed by hearing aids ,” J. Acoust. Soc. Am . 68 , 458 – 466 ( 1980 ). 7419804
24. Hall JL , “ Application of multidimensional scaling to subjective evaluation of coded speech ,” J. Acoust. Soc. Am . 110 , 2167 – 2182 ( 2001 ). 11681393
25. Mayo C , Clark RA , and King S , “ Listeners’ weighting of acoustic cues to synthetic speech naturalness: A multidimensional scaling analysis ,” Speech Commun . 53 , 311 – 326 ( 2011 ).
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.