최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국방사선학회 논문지 = Journal of the Korean Society of Radiology, v.16 no.2, 2022년, pp.131 - 139
황형석 (인제대학교 해운대백병원 영상의학과) , 임인철 (동의대학교 방사선학과)
The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standar...
U. Linsenmaier, M. Krotz, H. Hauser, C. Rock, J. Rieger, K. Bohndorf, K. Pfeifer, M. Reiser, "Whole-body computed tomography in polytrauma: techniques and management", Europe Radiology, Vol. 12, No. 7, pp. 1728-1740, 2002. http://dx.doi.org/10.1007/s00330-001-1225-x
M. L. Van Hise, S. L. Primack, R. S. Israel, N. L. Muller, "CT in blunt chest trauma: indications and limitations", Radiographics :a review publication of the Radiological Society of North America, Inc, Vol. 18, No. 5, pp. 1071-1084, 1998. http://dx.doi.org/10.1148/RADIOGRAPHICS.18.5.9747608
J. U. Yoo, A. Ghanauem, C. Petersilge, J. Lewin, "Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine", Spine, Vol. 22, No. 22, pp. 2668-2671, 1997. http://dx.doi.org/10.1097/00007632-199711150-00016
J. W. Jang, I. H. Jo, H. J. Kim, W. J. Jeong, B. G. Go, J. T. Lee, H. S. Yoo, B. H. Yoo, "The Usefulness of Applying The lterative MAR Algorithm for Improving of The Deterioration of CT Image Qulaity came from The High-Density Material", Journal of the Korean Society of Computed Tomographic Technology, Vol. 18, No. 2, p. 73, 2016.
H. J. Kim, H. C. Jang, J. H. Cho, "Evaluation on usefulness of three dimensional reconstructive computed tomography images after pedicle screws fixation", Journal of Digital Contents Society Vol. 11 No. 4, pp. 553-559, 2010.
H. S. Kim, H. J. Han, J. Y. Kim, C. P. Park, S. G. Jang, J. W. Choi, J. S. Kim, "O-MAR, SBI image comparison & analysis evaluation about patients who have metal artifical implants in the knee joint CT scan", Korean Society of Computed Tomographic Technology, Vol. 20, No. 1, pp. 33-50, 2018. http://dx.doi.org/10.31320/JKSCT.2018.20.1.33
M. C. Kim, Latest CT image technology theory QC edition, Chun-Ku Publishing Co., pp. 3-9, 2007.
M. S. kim, M. O. Jeong, J. S. Jeong, et al, "Clinical usefulness of MAR algoritm method for Beam-hardening artifact reduction in dual Energy Imaging via kVp Switching", Journal of Radiation Protection, Vol. 13, No. 2, pp. 21-23. 2011.
H. J. Kim, "Usefulness Evaluation of Application of Metallic Algorithm Reducing for Beam Hardening Artifact Occur in Typical Brain CT Image", "Journal of Korean Society Radiology, Vol. 12, No. 3, p. 393. 2018.
H. S. Keum, K. C. Jang, J. Choi, J. H. Lee, B. W. Lee, J. S. Seo, W. S. Kim, "The Experimental Study about Reduction Method of Metal Artifact by Using Single Source Dual Energy CT", Journal of Korean Society of Computed Tomographic Technology, Vol. 13, No. 1, p. 85, 2011.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.