최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국구조물진단유지관리공학회 논문집 = Journal of the Korea Institute for Structural Maintenance and Inspection, v.26 no.2, 2022년, pp.68 - 75
양희원 (부경대학교 토목공학과) , 이환우 (부경대학교 토목공학과)
In this study, in order to directly evaluate the prestress of the PSC structure, a new sensor module based on the measurement of the deformation of concrete was proposed using hetero-core optical fibers and performance tests were performed. In a hetero-core optical fiber, optical loss occurs when a ...
Sumitro, S., Hida, K., Diouron, T. Le. (2003), Structural Health Monitoring Paradigm for Concrete Structures, 28th Conference on Our World in Concrete & Structures, CI-PREMIER PTE LTD, Singapore, 525-532.
Lee, S. C., Choi, S. Y., Shin, K. J., Kim, J. M., Lee, H. W. (2015), Measurement of Transfer Length for a Seven-Wire Strand with FBG Sensors, Journal of Computational Structural Engineering Institute of Korea, 28(6), 707-714.
Wang, M. L., Chen, Z. (2000), Magneto-Elastic Permeabitilty Measurement for Stress Monitoring in Steel Tendons and Cables, Proc. of the SPIE 7th Annual Symposium on Smart Structures and Materials, Health Monitoring of the Highway Transportation Infrastructure, 3995, 492-500.
Measures, R. M., Alavie, A. T., Maaskant, R., Ohn, M., Karr, S., Huang, S. (1994), Bragg Grating Structural Sensing System for Bridge Monitoring, Proc. of the SPIE 1994, 2294, 53-60.
Maaskant, R., Alabie, T., Measures, R. M., Tadros, G., Rizkalla, S. H., Guha-Thakurta, A. (1997), Fiber-Optic Bragg Grating Sensors for Bridge Monitoring, Cement & Concr. Compos., 19, 21-33.
Kim, H. W., Kim, J. M., Choi, S. Y., Park, S. Y., Lee, H. W. (2015), Long Term Monitoring of Prestressing Tension Force in Post - Tension UHPC Bridge using Fiber Optical FBG Sensor, Journal of Computational Structural Engineering Institute of Korea, 28(6), 699-706.
Roller, J. J., Russell, H. G., Brucr Jr, R. N., Alaywan, W. R. (2011), Evaluation of Prestress Losses in High-strength Concrete Bulb-tee Girders for the Rigolets Pass Bridge, PCI J., 56(1), 110-134.
Inaudi, D. (1994), Low-Coherence Deformation Sensors for the Monitoring of Civil Engineering Structures, Sens. & Actuators A, 44, 125-130.
Idriss, R. L. (2001), Monitoring of a High Performance Prestressed Concrete Bridge with Embedded Optical Piber Sensors during Fabrication, Construction and Service, Proceedings of the 9th International Conference Structural Faults Repair, London.
Gauthuer, R. C., Ross, C. (1997), Theoretical and experimental considerations for a single-mode fiber-optic bend-type sensor, Applied Optics, 36(25), 6264-6273.
Marcuse, D. (1976), Curvature loss fomula for optical fibers, Journal of Optical Society of America, 66(3), 216-220.
Donlagic, D., Culshaw, B. (2000), Propagation of the fundamental mode in curved graded index multimode fiber and its application in sensor system, Journal of Lightwave Technology, 18(3), 334-342.
Yoo, J. A., Jo, J. H., Kwon, I. B. (2004), Multiplexed Bend Loss Type Single-Mode Fiber-Optic Displacement Sensor Using Reflection Signals Generated at Optical Connectors, Journal of the Optical Society of Korea, 15(5), 415-422.
Snyder, A. W., Love, J. D. (1983), Optical Waveguide Theory, Chapman and Hall, London, 250-290.
Lee, K. H., Ahn, B. J., Kim, D. H. (2011), Fiber Optic Displacement Sensor System for Structural Health Monitoring, Journal of the Korean Society for Nondesturctive Testing, 31(4), 374-381.
Kim, Y. B., Lee, K. S., Watanabe, K., Sasaki, H., Choi, Y. W. (2007), Hetero-core Spliced Fiber Optical Sensing System for an Environment Monitoring, Journal of Ocean Engineering and Technology, 21(3), 46-51.
Park, K. T. (2007), The State of the Art on Bridge Monitoring by using Fiber Optic Sensor, Journal of the Korea Institute for Structural Maintenance and Inspection, 11(5), 3-9.
Park, Y. S., Song, K. T., Jin, S. S., Park, Y. H., Kim, S. T. (2020), Optical Fiber-Based Hybrid Nerve Measurement System for Static and Dynamic Behavior of Structures, Journal of the Korea Institute for Structural Maintenance and Inspection, 24(2), 33-40.