최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Journal of biomedical engineering research : the official journal of the Korean Society of Medical & Biological Engineering, v.43 no.2, 2022년, pp.124 - 130
조한석 (한밭대학교 전자공학과) , 강영환 (한밭대학교 전자공학과) , 박재순 (한밭대학교 전자공학과) , 최진규 (한밭대학교 전자공학과) , 정연호 (한밭대학교 전자공학과) , 구치완 (한밭대학교 전자공학과)
In this paper, we proposed a portable electronic cardiogram and stethoscope (ECGS) that can simultaneously perform the electrocardiogram (ECG) and auscultation tests to increase the reliability of diagnosis of heart disease. To measure the ECG and heart sound (HS) at the same time, three ECG electro...
Lee K, Ji Y, Jeon Y, Park YC. Development and implementation of noise-canceling technology for digital stethoscope. J Biomed Eng Res. 2013;34(4):204-11.
Mangione S. The teaching and practice of cardiac auscultation during internal medicine and cardiology training: A nationwide survey. Ann. Intern. Med. 1993;119(1):47-54.
Favrat B, Pecoud A, Jaussi A. Teaching cardiac auscultation to trainees in internal medicine and family practice: Does it work?. BMC Med. Educ. 2004;4(1):5.
Lam MZ, Lee TJ, Boey PY, Ng WF, Hey HW, Ho KY, et al. Factors influencing cardiac auscultation proficiency in physician trainees. Vol. 46, Singapore Med J. 2005;46(1):11-4.
Vukanovic-Criley JM, Criley S, Warde CM, Boker JR, Guevara-Matheus L, Churchill WH, et al. Competency in cardiac examination skills in medical students, trainees, physicians, and faculty. Arch. Intern. Med. 2006;166(6):610-6.
Mathias DN, Kim SI, Park JS, Joung YH. Real time ECG monitoring through a wearable smart T-shirt. Trans. Electr. Electron. Mater. 2015;16(1):16-9.
Kang YH, Park JS, Cho BK, Choi SD, Joung YH. Study on characteristics of ECG electrodes for motion artifact reduction. J. Korean Inst. Electr. Electron. Mater. Eng. 2017;30(6):366-71.
Lee JH, Lee YJ, Lee KH, Kang SJ, Kim KN, Park HJ, et al. Study of the wearable electrocardiogram measuring system using capacitive-coupled electrode. Trans. Korean Inst. Electr. Eng. 2014;63(10):1448-54.
Kang, Y.H. A study on development of capacitance ECG electrode to reducing motion artifact. MS thesis, Dept. Cont. Instrum. Eng., Hanbat Natl. Univ., Korea. 2018.
Mathias DN, Kim S il, Park JS, Joung YH, Choi WS. Electrode characteristics of non-contact electrocardiographic measurement. Trans. Electr. Electron. Mater. 2015;16(1):42-5.
Wang W, Xu Q, Zhang G, Lian Y, Zhang L, Zhang X, et al. A bat-shape piezoresistor electronic stethoscope based on MEMS technology. Measurement. 2019;147:106850.
Arvin F, Doraisamy S, Khorasani ES. Frequency shifting approach towards textual transcription of heartbeat sounds. Biol. Proced. Online. 2011;13:1-7.
Klabunde RE. Cardiac electrophysiology: normal and ischemic ionic currents and the ECG. Adv. Physiol. Educ. 2017;41:29-37.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
출판사/학술단체 등이 한시적으로 특별한 프로모션 또는 일정기간 경과 후 접근을 허용하여, 출판사/학술단체 등의 사이트에서 이용 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.