최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국방사선학회 논문지 = Journal of the Korean Society of Radiology, v.16 no.3, 2022년, pp.281 - 288
민병인 (인제대학교 원자력응용공학부) , 임인철 (동의대학교 방사선학과)
In this study, four algorithms (Soft, Standard, Detail, Bone) were used for general CT scan (Before MAR) images and MAR (After MAR) images for patients with metal implants inserted into the hip joint. was applied to compare and analyze Noise, SNR, and CNR to find out the optimal algorithm for quanti...
Managing Patient Dose in Multi-Detector Computed Tomography(MDCT), ICRP 102, 2007.
D. C. Kweon, B. G. Yoo, J. S. Lee, K. J. Jang, "A Method to CT Attenuation Coefficient and Image Noise of Various Convolution Kernel in the Computed Tomography", Korean Journal of Digital Imaging in Medicine, Vol. 9, pp. 21-30, 2009.
M. Okumura, T. Ota, S. Tsukagoshi, K. Katada, "New Method of Evaluating Edge-preserving Adaptive Filters for Computed Tomography(CT) Digital Phantom Method", Japanese Journal of Radiological Technology, Vol. 62, No. 7, pp. 971-978, 2006. http://dx.doi.org/10.6009/jjrt.62.971
H. S. Yoon, "Predict of Fracture Risk Rate According to Morphological Measuring of Proximal Femoral Part Using Dual Energy X-ray Absoptiometry", Journal of Korean Society of radiological technology, Vol. 25, pp. 49-53, 2002.
S. J. Kim, S. W. Yoo, J. C. Kim, S. M. Noh, J. W. Park, "A Study on the Segmentation of Kidney from the Non Enhanced CT Image", Journal of Korean Institute of Information Scientists and Engineers, Vol. 27, pp. 514-516, 2000.
M. D. Becker, Y. M. Berkmen, J. H. M. Austin, I. K. Mun, B. M. Romney, A. Rozenshtein, P. A. Jellen, C. K. Yip, B. Thomashow, M. E. Ginsburg, "Lung volumes before and after lung volume reduction surgery: quantitative CT analysis", American Journal of Respiratory and Critical Care Medicine, Vol. 157, No. 5, pp. 1593-1599, 1998. http://dx.doi.org/10.1164/AJRCCM.157.5.9706066
G. W. Kim, J. H. Min, K. Y. Yoo, J. M. Kim, H. W. Joung, J. A. Lee, J. H. Jung, D. H. Sung, S. C. Park, "Comparison Study on CNR and SNR of Thoracic Spine Lateral Radiography", Journal of Radiological Science and technology, Vol. 36, No. 4, p. 273-280, 2013.
M. C. Kim, Actual performance management of CT device CT, Korean Society Computed Tomographic Technology 2th Continuing education, pp. 53-66, 2002.
http://www.gehealthcare.com/MAR
The Korean society of medical imaging technology, Textbook of Computed Tomography, Chung-Ku Publishing corporation, Fourth edition, p. 430, 2017.
H. S. Kim, H. J. Han, J. Y. Kim, C. P. Park, S. G. Jang, J. W. Choi, J. S. Kim, "O-MAR, SBI image comparison & analysis evaluation about patients who have metal artifical implants in the joint CT scan", Korean Society of Computed Tomography Technology, Vol. 20, No 1, pp. 34-35, 2018. http://dx.doi.org/10.31320/JKSCT.2018.20.1.33
C. M. Park, M. J. Jung, J. H. Ha, "The Usefulness of O-MAR(Metal Artifact Reduction for Orthopedic implant) for Patients with Dental Implant", Korean Society of Computed Tomography Technology, Vol. 17, No. 2, pp. 157-167, 2015.
D. H. Kim, J. N. Byun, C. H. Moon, J. H. Jang, "Usefulness of Metal artifact Reduction for metal Implants in Computed Tomography Angiography", The Medical Journal of Chosun University, Vol. 39, No. 1, pp. 20-24, 2014.
The Korean society of medical imaging technology, Textbook of Computed Tomography, Chung-Ku Publishing corporation, Fourth edition, pp. 75, 2014.
D. K. Han, K. J. Park, K. Ko, "The Evaluation of Image Quality According to the Change of Reconstration Algorithm of CT Image", Korean Journal Digital Imaging Medicine, Vol. 12, No. 2, pp. 127-132, 2010.
J. Nosil, K. I. Pearce, R. A. Stein, "Linearity and contrast scale in computed tomography", Medical Physics, Vol. 16, No. 1, pp. 110-113, 1989. http://dx.doi.org/10.1118/1.596396
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.