Purpose : This study aimed to compare peripheral pulse oxygen saturation (SpO2) values, measured at different monitoring sites, and arterial oxygen saturation (SaO2) of neurocritical patients. Methods : The study included 110 patients admitted to the neurosurgical intensive care unit of a university...
Oddo M, Bosel J. Monitoring of brain and systemic?oxygenation in neurocritical care patients. Neurocritical Care. 2014;21(S2):103-20. https://doi.org/10.1007/s12028-014-0024-6
Miller CM, Torbey MT. Neurocritical care monitoring.?New York: DEMOS Medical; 2015.
Lopez HV, Vivas MF, Ruiz RN, Martinez JR, Navaridas BG-V, Villa MG, et al. Association between?post-procedural hyperoxia and poor functional outcome after mechanical thrombectomy for ischemic?stroke: an observational study. Annals of Intensive?Care. 2019;9(1):1-10. https://doi.org/10.1186/s13613-019-0533-8
Hoesch RE, Lin E, Young M, Gottesman RF,?Altaweel L, Nyquist PA, et al. Acute lung injury in?critical neurological illness. Critical Care Medicine.?2012;40(2):587-93. https://doi.org/10.1097/CCM.0b013e3182329617
Ko SB. General management of acute stroke. Journal?of the Korean Medical Association. 2009;52(4):334-9. https://doi.org/10.5124/jkma.2009.52.4.334
Byrne AL, Bennett M, Chatterji R, Symons R, Pace?NL, Thomas PS. Peripheral venous and arterial blood?gas analysis in adults: are they comparable? a?systematic review and meta-analysis. Respirology.?2014;19(2):168-75. https://doi.org/10.1111/resp.12225
Hinkelbein J, Fiedler F, Hose D. Comparison of?three different sensor sites for pulse oximetry in?critically ill patients. International Journal of Intensive?Care. 2005;12(4):159-64.
Myatt R. Pulse oximetry: what the nurse needs to?know. Nursing Standard. 2017;31(31):42-5. https://doi.org/10.7748/ns.2017.e9940
Wouters PF, Gehring H, Meyfroidt G, Ponz L, Gil-Rodriguez J, Hornberger C, et al. Accuracy of?pulse oximeters: the European multi-center trial.?Anesthesia and Analgesia. 2002;94(1):13-6.
Valdez-Lowe C, Ghareeb SA, Artinian NT. Pulse?oximetry in adults. American Journal of Nursing.?2009;109(6):52-9. https://doi.org/10.1097/00000446-200906000-00036
DeMeulenaere S. Pulse oximetry: uses and limitations.?The Journal for Nurse Practitioners. 2007;3(5):312-7. https://doi.org/10.1016/j.nurpra.2007.02.021
Jubran A. Pulse oximetry. Critical Care. 2015;19(1):1-7. https://doi.org/10.1186/s13054-015-0984-8
Nesseler N, Frenel J-V, Launey Y, Morcet J, Malledant Y, Seguin P. Pulse oximetry and high-dose?vasopressors: a comparison between forehead reflectance?and finger transmission sensors. Intensive Care Medicine. 2012;38(10):1718-22. https://doi.org/10.1007/s00134-012-2659-0
Schallom L, Sona C, McSweeney M, Mazuski J.?Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral?perfusion. Heart & Lung. 2007;36(3):188-94. https://doi.org/10.1016/j.hrtlng.2006.07.007
Hodgson CL, Tuxen DV, Holland AE, Keating JL.?Comparison of forehead max-fast pulse oximetry?sensor with finger sensor at high positive end-expiratory pressure in adult patients with acute?respiratory distress syndrome. Anaesthesia and Intensive?Care. 2009;37(6):953-60. https://doi.org/10.1177/0310057x0903700620
Seifi S, Khatony A, Moradi G, Abdi A, Najafi F.?Accuracy of pulse oximetry in detection of oxygen?saturation in patients admitted to the intensive care?unit of heart surgery: comparison of finger, toe, forehead and earlobe probes. BMC Nursing. 2018;17(1). https://doi.org/10.1186/s12912-018-0283-1
Wax DB, Rubin P, Neustein S. A comparison of?transmittance and reflectance pulse oximetry during?vascular surgery. Anesthesia and Analgesia. 2009;109(6):1847-9. https://doi.org/10.1213/ane.0b013e3181bbc446
Faul F, Erdfelder E, Lang A-G, Buchner A. G* Power 3: a flexible statistical power analysis program?for the social, Behavioral, and Biomedical Sciences.?Behavior Research Methods. 2007;39(2):175-91.
Chan ED, Chan MM, Chan MM. Pulse oximetry:?understanding its basic principles facilitates appreciation of its limitations. Respiratory Medicine. 2013;107(6):789-99. https://doi.org/10.1016/j.rmed.2013.02.004
Castro D, Patil SM, Keenaghan M. Arterial Blood?Gas [Internet]. Treasure Island, FL: StatPearls Publishing; 2022 [cited 2023 February 22]. Available from:?https://www.ncbi.nlm.nih.gov/books/NBK536919/
Powers WJ, Rabinstein AA, Ackerson T, Adeoye OM,?Bambakidis NC, Becker K, et al. 2018 guidelines?for the early management of patients with acute?ischemic stroke: a guideline for healthcare professionals?from the American Heart Association/American Stroke?Association. Stroke. 2018;49(3):e49-99. https://doi.org/10.1161/str.0000000000000158
Badenes R, Bilotta F. Neurocritical care for intracranial?haemorrhage: a systematic review of recent studies.?British Journal of Anaesthesia. 2015;115:ii68-74.?https://doi.org/10.1093/bja/aev379
Rincon F, Kang J, Maltenfort M, Vibbert M, Urtecho?J, Athar MK, et al. Association between hyperoxia?and mortality after stroke. Critical Care Medicine.?2014;42(2):387-96. https://doi.org/10.1097/ccm.0b013e3182a27732
Frei DR, Young PJ. Oxygen therapy in acute resuscitation. Current Opinion in Critical Care. 2018;24(6):506-11. https://doi.org/10.1097/mcc.0000000000000549
Jo YJ. Latest updates of oxygen therapy. Spring?Conference of the Korean Journal of Internal?Medicine. 2019:153-6.
Jeon S-B, Choi HA, Badjatia N, Schmidt JM, Lantigua H, Claassen J, et al. Hyperoxia may be related?to delayed cerebral ischemia and poor outcome after?subarachnoid haemorrhage. Journal of Neurosurgery?& Psychiatry. 2014;85(12):1301-7. https://doi.org/10.1136/jnnp-2013-307314
European Stroke Organization [ESO] Executive Committee, ESO Writing Committee. Guidelines for management of Ischaemic stroke and transient ischaemic?attack 2008. Cerebrovascular Diseases. 2008;25(5):457-507. https://doi.org/10.1159/000131083
Liao JJ. An improved concordance correlation coefficient. Pharmaceutical Statistics. 2003;2(4):253-61. https://doi.org/10.1002/pst.52
Lee WW, Mayberry K, Crapo R, Jensen RL. The?accuracy of pulse oximetry in the emergency department. The American Journal of Emergency Medicine.?2000;18(4):427-31.
Munoz X, Torres F, Sampol G, Rios J, Marti S, Escrich?E. Accuracy and reliability of pulse oximetry at different arterial carbon dioxide pressure levels. European?Respiratory Journal. 2008;32(4):1053-9.
Haynes JM. The ear as an alternative site for a pulse?oximeter finger clip sensor. Respiratory Care. 2007;52(6):727-9.
Louw A, Cracco C, Cerf C, Harf A, Duvaldestin P,?Lemaire F, et al. Accuracy of pulse oximetry in the?intensive care unit. Intensive Care Medicine. 2001;27(10):1606-13. https://doi.org/10.1007/s001340101064
Seguin P, Le Rouzo A, Tanguy M, Guillou YM, Feuillu?A, Malledant Y. Evidence for the need of bedside?accuracy of pulse oximetry in an intensive care unit.?Critical Care Medicine. 2000;28(3):703-6. https://doi.org/10.1097/00003246-200003000-00017
Han DJ, Bang CH, Kim S, Bae YM, Shin SR, Yang?CY, et al. Comparison of peripheral blood flow in?post-stroke hemiparetic patients and normal person?with doppler ultrasonography. Korean Journal of?Oriental Physiology & Pathology. 2009;23(6):1491-6.
Numaguchi A, Adachi YU, Aoki Y, Ishii Y, Suzuki?K, Obata Y, et al. Radial artery cannulation decreases?the distal arterial blood flow measured by power?doppler ultrasound. Journal of Clinical Monitoring?and Computing. 2014;29(5):653-7. https://doi.org/10.1007/s10877-014-9648-5
Milutinovic D, Repic G, Arandelovic B. Clinical?nurses' knowledge level on pulse oximetry: a descriptive multi-centre study. Intensive and Critical Care?Nursing. 2016;37:19-26. https://doi.org/10.1016/j.iccn.2016.05.006
World Health Organization [WHO]. Pulse oximetry?training manual [Internet]. Switzerland: World Health?Organization; 2011 [cited 2022 November 15]. Available from: https://cdn.who.int/media/docs/default-source/patient-safety/pulse-oximetry/who-ps-pulse-oxymetry-training-manual-en.pdf?sfvrsn322cb7ae_6.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.